Analysis of Temperature Rise on the Air-Guide's Position of Wind Power Generator

풍력발전기 Air Guide 위치별 온도상승 해석

  • 한창우 ((주)효성 중공업연구소 기반기술팀) ;
  • 김현재 ((주)효성 중공업연구소 기반기술팀) ;
  • 권기영 ((주)효성 중공업연구소 기반기술팀) ;
  • 이학성 ((주)효성 중공업연구소)
  • Published : 2008.10.16

Abstract

In this paper, the numerical analysis of the model without air-guide was carried out in wind power generator. From numerical results, the temperature rise was not satisfied for the class F insulation and the non-uniformity of temperature distribution was a wide difference in heating elements. To improve these problems, the air-guide was installed in front of the coil head of non-drive end(NDE). The short distance between coil head and air-guide was more effective than long distance in cooling performance. Compared to that of the preliminary design, it was found that the cooling performance of the modification design was improved about 12%.