A Research on Optimization of Lead-lag Controller Setpoint for Rod control system to prevent fluctuation for NPP

원전 제어봉제어계통 순시변동을 방지하기위한 지상-지연회로 설정치 최적화 연구

  • Published : 2007.05.30

Abstract

Fluctuation of control rod was experienced when plant was operating in normal operation mode in WH type NPPs. In order to cope with increased control rod fluctuation, the lead-lag controller setpoint for rod control system was optimized and resulted in increasing the margin of operation and minimizing unnecessary control rod movement. By optimization of the time constant, the margin of operation was increased by $1.5^{\circ}F$ and the control rod movement was not occurred due to mitigation of temperature fluctuation in loop. According to the mitigation of time constant, the margin of operation was increased but safety margin can be affected badly, so that the influences to FSAR design reference was evaluated. As the result of this evaluation, it satisfied the design reference of the existing safety analysis and was applied to NPP after obtaining the approval.

Keywords