Analysis of Squirrel Cage Induction Motors with Stator Winding Inter-turn Short Circuit

고정자 권선 단락에 따른 농형 유도전동기의 특성해석

  • 김미정 (동아대학교 전기공학과) ;
  • 김병국 (동아대학교 전기공학과) ;
  • 문지우 (동아대학교 전기공학과) ;
  • 조윤현 (동아대학교 전기공학과) ;
  • 황돈하 (한국전기연구원 전력설비진단연구그룹) ;
  • 강동식 (한국전기연구원 전력설비진단연구그룹)
  • Published : 2007.04.19

Abstract

The stator faults yield asymmetrical operation of induction machines, such as irregular current, torque pulsation, increased losses and decreased average torque. So it is necessary to detect the stator faults and develope the monitoring system for detecting faults including vibration and noise. This paper describes the method to analysis the induction motors with the stator winding inter-turn short for investigation of the asymmetrical operation during normal and transient states. And a simple method is used for the simulation and analysis of the induction machines with stator asymmetries. Finally, simulation results, finite element analysis and experimental ones are presented. The results can be useful for real-time on-line monitoring of an induction motor.

Keywords