선형 및 비선형 TLD의 지진응답 제어성능 평가

Seismic Response Control Performance of Linear and Nonlinear TLD Models

  • 이상현 (단국대학교 건축대학 건축공학과) ;
  • 우성식 (단국대학교 건축공학과) ;
  • 정란 (단국대학교 건축공학과)
  • 발행 : 2006.03.17

초록

This paper compares the seismic response control performance of linear and non-linear models fer tuned liquid damper (TLD). The existing linear and nonlinear TLD models were used for the numerical analysis of single degree of freedom (SDOF) and multi degree of freedom (MDOF) systems with TLD. The nonlinear model considers the variation of the frequency and damping of the TLD with varying excitation amplitude while the linear one has the invariant parameters. Numerical analysis results from SDOF systems indicate that the nonlinear model shows about 5% better control performance than linear one when the mass ratio is 2% and the optimal parameters for reducing peak responses are dependent on the characteristics of the excitation earthquake loads.

키워드