층응답을 고려한 소형면진장치의 진동대실험

A Shaking Table Test of Small Isolation System Considering the Floor Response

  • 김민규 (한국원자력연구소 종합안전평가부) ;
  • 전영선 (한국원자력연구소 종합안전평가부) ;
  • 이경진 (전력연구원 구조연구실 내진기술그룹)
  • 발행 : 2005.03.18

초록

This paper presents the results of experimental studies on the equipment isolation effect considering the floor response. For this purpose, shaking table tests were performed. For the measuring the floor response, numerical analysis was performed. For the isolation for the equipment, Natural Rubber Bearing(NRB), High Damping Rubber Bearing(HDRB) and Friction Pendulum System(FPS) were used. Finally, it is presented that the isolation systems used in this test can be adopted for the small equipment isolation. But the rubber bearing used in this study affected to the temperature change very sensitively.

키워드