Application of Finite Element Method and Taguchi Method to Reduce Floor Impact Vibration in Apartment Buildings

공동주택의 바닥충격진동 저감을 위한 유한요소법 및 다구찌법의 활용

  • 서상호 (한양대학교 대학원 건축공학과) ;
  • 전진용 (한양대학교 건축대학 건축공학부)
  • Published : 2005.11.01

Abstract

Finite element method and Taguchi method were used to reduce the floor impact vibration of the reinforced concrete slab in the apartment buildings. At first, experimental results show that sound peak components to influence the rating of floor impact sound insulation were coincident with natural frequencies of the reinforced concrete slab, and there is a high linear relation between floor impact vibration and sound. The tables of orthogonal arrays were used for finite element analysis with 5 factors related to slab shape parameters and its results were analyzed by statistical method. The most effective factor to reduce the floor impact vibration was the length of living/kitchen room and the floor impact vibration was predicted by 30% reduction in the acceleration peak by the optimal design values of the factors.

Keywords