Force Feedback Control of 3 DOF Haptic Device Utilizing Electrorheological Fluid

ER 유체를 이용한 3 자유도 햅틱 장치의 힘 반향 제어

  • 한영민 (인하대학교 대학원 기계공학과) ;
  • 강필순 (인하대학교 대학원 기계공학과) ;
  • 최승복 (인하대학교 기계공학과)
  • Published : 2005.11.01

Abstract

This paper presents force feedback control performance of a 3DOF haptic device that can be used for minimally invasive surgery (MIS). As a first step, a 3DOF electrorheological (ER) joint is designed using a spherical mechanism. And it is optimized based on the mathematical torque modeling. Subsequently, the master haptic device is manufactured by the spherical joint. In order to achieve desired force trajectories, model based compensation strategy is adopted for the ER master. Therefore, Preisach model fur the PMA-based ER fluid is identified using experimental first order descending (FOD) curves. A compensation strategy is then formulated through the model inversion to achieve desired force at the ER master. Tracking control performances for sinusoidal force trajectory are presented, and their tracking errors are evaluated.

Keywords