Influence of NCG Charging Mass on the Thermal Characteristics of Variable Conductance Heat Pipe with Screen Mesh Wick

스크린 메쉬형 가변전열 히트파이프에서 NCG양에 따른 작동특성 변화

  • 서정세 (경상대학교 기계항공공학부, 항공기부품 기술 연구센터) ;
  • 박영식 (경상대학교 대학원) ;
  • 강창호 (경상대학교 대학원) ;
  • 정경택 (경상대학교 대학원) ;
  • 박기호 (한국에너지기술연구원 폐열이용연구센터) ;
  • 이기우 (한국에너지기술연구원 폐열이용연구센터)
  • Published : 2004.04.28

Abstract

Experimental study is performed to investigate the effect of heat load and operating temperature on the thermal performance of a heat pipe with screen mesh wick. The heat pipe was designed in 200 screen meshes, 500mm length and 12.7mm O.D tube of copper, water as working fluid(4.8g) and nitrogen as non-condensible gas(NCG). The heat pipe used in this study has evaporator, condenser and adiabatic section, respectively. Experimental data of axial wall temperature distribution is presented for heat transport capacity, the temperature of cooling water of condenser, inclination angle, and operating temperature. For the results from this study, it is found that, for the same charging mass of working fluid, the initial operating temperature and the overall wall temperatures of heat pipe are higher for NCG charging mass of $5.0{\times}10^{-6}kg$ and $3.4{\times}10^{-6}kg$, than that of $1.0{\times}10^{-6}kg$.

Keywords