Investigation on Transient Vibration of Piping System to Heater in a Power Plant

발전소 가열기 급수용 배관계 이상 진동 고찰

  • Published : 2004.05.01

Abstract

There was transient vibration on the piping system from #4 heater to the deaerator in a power plant. We found it was resulted from resonance between the natural vibration of the piping system and vibration induced by flow of feedwater. We verified it would reduce vibration by increasing stiffness of the piping system. Therefore we concluded that it would be generally better to increase stiffness of the piping system to reduce vibration amplitude of 10Hz low for big sized piping systems.

Keywords