유체기계공업학회:학술대회논문집
- 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
- /
- Pages.154-160
- /
- 2003
가중계수에 의한 다회선 초음파 유량계의 유량적분오차
Flowrate Integration Errors of Multi-path Ultrasonic Flowmeter using Weighting Factors
- 발행 : 2003.12.05
초록
Multi-path ultrasonic flowrate measuring technology is being received much attentions from a variety of industrial fields to exactly measure the flowmeter. Multi-path ultrasonic flowmeter has much advantage since it has no moving parts and not occurred pressure loss. It offers good accuracy, repeatability, linearity and Tum-down ratio can measure over 1:50. The present study investigates flowrate integration errors using weighting factors. A theoretical flow model uses power law to describe a fully developed velocity profiles and wall roughness changes. The methods of weighting factor simulate three configurations of measuring location of gaussian, chebyshev and tailor method. The obtained results show that many chord arrangements are not affected for wall roughness changes and can measure accurate flowrate.