한국소음진동공학회:학술대회논문집 (Proceedings of the Korean Society for Noise and Vibration Engineering Conference)
- 한국소음진동공학회 2002년도 추계학술대회논문초록집
- /
- Pages.336.1-336
- /
- 2002
- /
- 1598-2548(pISSN)
정수장용 교반기 시설의 과진동 원인 분석
Investigation on the Excessive Vibration of A Mixer Facility in A Water Purification Plant
- Park, Jinho (Korea Atomic Energy Research Institute) ;
- Lee, Jeong-Han ;
- Kim, Bong-Soo ;
- Kang, Mun-Hu ;
- Kim, Dong-Soo ;
- Joo, Yoon-Sik
- 발행 : 2002.11.01
초록
Recently, mixers are being widely used in the water purification plant in order to increase the filtration efficiency. The cause of an excessive vibration of a base structure to which the mixers are supported, has been evaluated through modal analysis on the mixer shaft and vibration measurements during operation. The fundamental natural frequency of the mixer shaft is found to be around 1.8 Hz and the main vibratory frequency around 30 Hz. (omitted)