Reliability Assessment of Ultrasonic Nondesturcive Inspection on Piping in NPP - The Result of PD-RR Test - (Part I)

원전 배관 초음파 비파괴검사의 신뢰도 평가 - PD-RR Test Results - (I)

  • 박익근 (서울산업대학교 비파괴평가기술연구소) ;
  • 박은수 (서울산업대학교 비파괴평가기술연구소) ;
  • 김현묵 (한양대학교 대학원) ;
  • 박윤원 (한국원자력안전기술원) ;
  • 강석철 (한국원자력안전기술원) ;
  • 최영환 (한국원자력안전기술원) ;
  • 이진호 (한국원자력안전기술원)
  • Published : 2001.11.01

Abstract

The performance demonstration round robin test was conducted to quantify the capability of ultrasonic inspection for in-service and to address some aspects of reliability for nondestructive evaluation. The fifteen inspection teams who employed procedures that met or exceeded ASME Sec. XI code requirements detected the pinping of nuclear power plant with various cracks to evaluate the capability of detection. With data from PD-RR test, the performance of ultrasonic nondestructive inspection could be assessed using probability of detection and length and depth sizing of cracks.

Keywords