대한기계학회:학술대회논문집 (Proceedings of the KSME Conference)
- 대한기계학회 2001년도 춘계학술대회논문집A
- /
- Pages.877-882
- /
- 2001
Sub-modeling을 이용한 end-to-end 문합의 비선형 해석
Nonlinear Analysis of End-to-End Anastomosis Using Sub-modeling
- 발행 : 2001.06.27
초록
A finite element analysis of end-to-end artery/PTFE anastomosis has been presented in this study to evaluate the distribution of compliance and stresses in the vicinity of the anastomosis due to any mismatch in compliance characteristics. The artery wall was assumed to be made of linear isotropic material in this simplified model and a nonlinear analysis and convergency study with respect to increasing meshed element numbers were performed with a mean artery pressure loading of the artery-PTFE model. Also, sub-modeling method was introduced to progress the accuracy of the finite element analysis. The results are as follow : 1. A hypercompliant zone on the artery side was observed around 4.0mm from the anastomosis and a high hoop stresses in the wall of artery and PTFE was dominent. 2. An artery displays large deformation so that nonlinear analysis and sub-modeling method was used. 3. An anastomosis with the thinner thickness and larger diameter PTFE (C type) could reduce the compliance disagreement.