Error Estimate of Local Vibration for Building Structures Using Substructure Models

부분구조모델을 이용한 건축물의 국부진동해석에서의 오차원인 분석

  • 안상경 (성균관대학교 건축공학과) ;
  • 이현수 (성균관대학교 건축공학과) ;
  • 이동근 (성균관대학교 건축공학과)
  • Published : 2001.10.01

Abstract

Analysis of a structure for vertical vibration requires a lot of computational efforts because large number of degrees of freedom are generally involved in the dynamic response. Especially, when a structure is loaded with local vibration source, it may not be economical to model the whole structure to obtain the responses of specific members located near or far from the sources. In this study, substructure models have been used for analysis of local vibration An analysis of local vibration is performed for the case that the loaded point and the response point are located on the same floor. Other analysis is performed for the case that the loaded point and the response point are located on the different floor. In this case, if only the floors on which loaded and response points are located are modeled, response of substructure model is very different from that of full model. So, there should be a consideration that degrees of freedom of floors in addition to those of loaded and response floors are included to improve results of dynamic analysis. In this study, floors between loaded floor and response floor were modeled so that modeshapes which affect the response are presented well.

Keywords