Analysis of faust cause & insulation degradation on the electrical equipments for railway

철도용 전기기기의 고장요인 및 절연열화 분석

  • 왕종배 (한국철도기술연구원 철도안전성능시험인증센터) ;
  • 전한준 (한국철도기술연구원 철도안전성능시험인증센터) ;
  • 박옥정 (한국철도기술연구원 철도안전성능시험인증센터) ;
  • 온정근 (한국철도기술연구원 철도안전성능시험인증센터)
  • Published : 2001.07.01

Abstract

Electrical equipment for railway is always experiencing wear and degradation by mechanical, electrical and environmental stress in service and the fault or the accident of high voltage main circuit directly causes operation interruption. Particularly propulsion drive of high speed switching inverter takes the form of specific degradation mechanism such as fast rising transient surge, reflective overvoltage and harmonic stress, and it is known that it threatens the long life and the reliability of electrical equipment. In this paper, statistics of fault and accident on main electrical equipment for railway are presented and also insulation degradation mechanism, which governs end life of electrical device, is analyzed. Finally the method of fault respondence and reliability improvement on the main electrical equipments will be reviewed in order to prevent operation interruption.

Keywords