An Experimental Study on the Flow Motion of the Working Fluid in Miniature Thermosyphons

미세 서모사이폰 내의 작동유체의 유동에 대한 실험적 연구

  • Published : 2000.04.20

Abstract

This experimental study investigated the flow motion of the working fluid for various diameters of miniature thermosyphons and the performance characteristics for the various amount of the working fluid. The temperatures of condenser surface were measured and visual observations were conducted. The test results show that some fluid condensed in the tube diameters of 0.18cm and 0.22cm is not returned to the evaporator section due to capillary effect so that large temperature gradients are measured. To enhance returning the working fluid, one copper wire of 0.5mm diameter was inserted and the test results show good performance. When the liquid charge was less than 10% in volume dry-out was occurred fur the thermosyphons of the inner diameter of 1.8mm and 2.2mm.

Keywords