Analysis of the Operation of a 3 Valve-type Pulse Tube Refrigerator

3 밸브형 맥동관 냉동기의 작동 해석

  • 송영식 (영남대학교 대학원 기계공학과) ;
  • 조경철 (영남대학교 대학원 기계공학과) ;
  • 정평석 (영남대학교 기계공학부)
  • Published : 2000.04.20

Abstract

A 3 valve-type pulse tube refrigerator optains its cooling effect from pressure drop by releasing the part of the charged gas through hot end nozzle. The objective of this study is to analyze the performance and to find an optimal expansion pressure of the 3 valve-type pulse tube refrigerator. It is assumed that gas lumps are not mixed and periodically repeat the adiabatic compression and expansion processes. And the nodal model is applied for the analysis of the regenerator. As the result of analysis, the optimum pressure at the end of expansion process was about 80-90% of the maximum pressure.

Keywords