Realization of Target Transfer Function higher than Type I

Type II이상인 목표전달함수의 구현

  • Published : 2000.10.01

Abstract

A time domain step response in which no overshoot occurs is demanded in many control application. Recently, Kim et al.[4,51 suggested some prototypes of target transfer functions of type I which can satisfy such a purpose. However, if a plant contains zeros more than one, then any output feedback control systems should have the same zeros in the closed-loop transfer function. In this paper, we propose two methods that choose the target transfer functions higher than Type I. These methods allow us to reduce the effect of zeros. It is shown through some examples that the proposed scheme can be effectively applied to the controller design problems with no overshoot.