Optimum Design of the Non-Destructive Testing System to Maximize the Magnetic Flux Leakages
- Park, G. S. (Dept. Electrical Engineering, Korea Maritime Univ.) ;
- P. W. Jang (Dept. Physics, Chongju Univ.) ;
- Park, Y. W. (KOGAS R&D Center)
- Published : 2000.09.01
Abstract
This paper describes the design method of the magnetic system to maximize the magnetic flux leakage (MFL) in non-destructive testing (NDT) system. The defect signals in MFL type NDT system mainly depends on the change of the magnetic leakage flux in the region of defect. The characteristics of the B-H curves are analyzed and the design method to define the operating point in B-H curves for the maximum leakage is performed. The computed MFL signal by nonlinear finite element method is verified by measurement using Hall sensors mounted on the 6 legs PIG in the 8 inches test tube with defects. The rhombic defects could be successfully composed from the defect signals.