An Experimental Study on the Flow at the Impeller Exit of a Centrifugal Pump

원심펌프의 회전차 출구 유동에 관한 실험적 연구

  • 강신형 (서울대학교 기계항공공학부) ;
  • 홍순삼 (서울대학교 대학원 기계공학과)
  • Published : 1999.12.01

Abstract

The flow at the impeller exit is important to validate engineering design and numerical analysis of pumps. However, it is not easy to measure the flow at the impeller exit and evaluate the impeller performance since there is usually strong interaction between the impeller and the volute casing. We installed axisymmetric collector instead of the volute casing, so there is no interaction between the impeller and casing. A 3-hole Cobra probe is used to investigate the flow at impeller exit and vaneless diffuser region for design and on design flow rate. For a single suction centrifugal pump of low specific speed, the flow field such as velocity, flow angle, and total pressure are measured by traversing the probe across the vaneless diffuser. These data can be used for performance prediction, desist and numerical analysis of pumps.

Keywords