ON MEASURING THE WELDING TEMPERATURE OF CONNECTOR

  • Deng Jyh-jeng (Industrial Engineering Department, Da-Yeh University)
  • Published : 1998.11.01

Abstract

The measurement of welding temperature of connector is usually performed with an infra red temperature gauge. However, the factors, which influence the temperature measurement, are rarely known. This research used the welding temperature measurement of the connector as an example, applying the experimental design, in two-phase experiments, to search the affecting factors. In phase-I experiment, we used a resolution III, seven-factor fractional factorial design with two levels for each factor. The result showed that none of the factor was significant in affecting the welding temperature when the type I error ${\alpha}$ was 0.05. Next, we did the phase-II factorial experiment with three factors and each factor had three levels. The experiment showed the experimental time was significant in affecting the temperature measurement when the type I error ${\alpha}$ was 0.05. Further Duncan's multiple range tests on the second experimental data showed that the later the experimental time, the weaker the light intensity could have on the temperature measurement and the average of the highest temperatures was lower. Moreover, the later the experimental time, the smaller was the variance of the temperature measurement and the difference between the averages of the highest and the lowest temperatures was also lower.

Keywords