Strength and Ductility of R/C Columns with Welded Reinforcement Grids

용접된 띠철근으로 보강한 철근콘크리트 기둥의 강도와 연성

  • 최창식 (정회원, 대진대학교 건축공학과교수) ;
  • ;
  • Published : 1997.04.01

Abstract

Experimental research was conducted to investigate structural performance of concrete columns confined with welded reinforcement grids were tested under simulated seismic loading. The columns were subjected to constant axial compression accompanied by incrementally increasing lateral deformation reversals. The results indicate thar welded reinforcement grid can be used effectively as confinement reinforcement provided that the steel used, have sufficient ductility and the welding process employed does not alter the strength and elongation characteristics of steel. The grids improved the structural performance of columns, which developed lateral drift ratios in excess of 3% with the spacing and volumetric ratio of transverse reinforcement similar to those required by the ACI 318-95 Building Code.