TV용 패널 검사대 최적조명설계에 관한 연구

  • 조항준 (포항공과대학교 산업공학과) ;
  • 김성환 (포항공과대학교 산업공학과) ;
  • 정의승 (포항공과대학교 산업공학과)
  • Published : 1995.04.01

Abstract

To investigate the effect of illumination conditions on visual inspection performance for TV panel glasses, three dependent variables, inspection time, error, and preference , were measured and analyzed through two consecutive experiments. The first experiment for reflection inspection was conducted using two independent variables, position and brightness. The second experiment for transparent inspection was made using two independent variables, height and brightness. The summary of the results of the experiment for reflection inspection are as follows ; The inspection performance of the position right above the subject (Position 1) was the best among the conditions in terms of errors, while the performance of the position slightly in front of and above the subject(Position 2) was the best in terms of inspection times. Inspection time was statistically different according to the brightness conditions specifically at the position in front of the subject(Position 3). The results of the second experimen for transparent inspection are that the inspection performance at medium height (Height 2) was the best among the three conditions in terms of errors while the performance at lower height(Height 3) was the best in subject preference. Based upon both results with respect to actual field conditions, two alternative inspection station designs were proposed for each lighting conditon.

Keywords