A Study on the Required Supply Water Temperature Calculating Method for the Control of Multizone Radiant Floor Heating System (멀티존 온돌난방제어를 위한 필요공급온수온도 산출법에 관한 연구)

  • Choi, Jeong-Min;Lee, Kyu-Nam;Ryu, Seong-Ryong;Kim, Yong-Yee;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.77-85
    • /
    • 2007
  • One of the most common approaches to achieve better thermal comfort with the radiant floor heating system is supply water temperature control, which is that supply water temperature is varied with outdoor air temperature. But the application of this control method was not easy, because there has been no way to determine the supply water temperature. So in this study, a comprehensive, yet simple calculation method to find out the required supply water temperature is suggested by combining the building heat loss equation and the heat emission model of hydronic radiant floor heating system for single zone. And then using this calculation method, the multizone control method is suggested and confirmed through the thermal simulation. It is shown that indoor air temperature is stably maintained around the set point.

ADPI Characteristics of Line Diffuser in a Room with Perimetric Heating Load (측벽 부하가 존재하는 공간에 설치된 라인 디퓨져의 ADPI 특성에 관한 연구)

  • Cho Young-Jin;Kang Seok-Youn;Moon Jong -Sun;Lee Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1204-1211
    • /
    • 2004
  • It is difficult to apply a conventional selection guide for diffusers when the diffuser is installed in a perimeter zone, because the air diffusion performance index (ADPI) vs. throw/length (T/L) ratio curve listed in conventional guide does not consider the perimetric heating load through the walls. The objective of this study is to evaluate the effect of the perimetric heating load on the ADPI and propose a selection guide for a proper line diffuser when perimetric heating load exists. The velocity and temperature distributions and the ADPI values are obtained numerically with various heat load ratios and air flow rates. The velocity and temperature distributions and the ADPI values are analyzed by CFD in case of various heat load ratios and air flow rates. Also, ADPI was calculated by those results. The ADPI values by numerical results are compared with an existing experimental data to verify the method for the evaluation of ADPI proposed in a present study. In case of a line diffuser installed at the high side wall, the ADPI decreases according to the increases of the flow rate on every heat load ratio of the present study except 0.75. The ADPI vs. T/L ratio curves have been proposed for the heat load ratios of 0.25, 0.5, 0.75 to guarantee the comport thermal environment when diffusers are installed in perimeter zone.

Mathematical Modeling for Calculating the Vertical Air Temperature Distribution in an Atrium Space (아트리움 공간의 수직공기온도분포 계산을 위한 수학모형의 작성)

  • 박종수;안병욱
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.533-542
    • /
    • 2003
  • This study aims to propose a simplified mathematical model for calculating vertical air temperature distribution in a four-sided atrium. In the first stage of the mathematical modeling, the computer model combined zonal model and solar radiation model using Monte Carlo method and Ray tracing technique went through a computer simulation with architectural variables applied to a four-sided atrium in summer. In the next stage, Curve Expert, a computer program that gets the most suitable solution ac-cording to the least squares method, is used to analyze the results of the computer simulation and to derive the mathematical model. The accuracy of the mathematical model was evaluated through a comparison of calculation results from a mathematical model and computer simulation. In this validation step using the least square method, the R2 value of the Zones 1, 2 and 3 showed higher than 0.945. Zone 4 has an R2 value of 0.911, lower than the previous three zones. However the relative error was below 0.5%, which is considered very small.

A study on characteristics of thermal comfort for artificial environmental experiment in winter (동계 인공환경실험에 의한 온열쾌적특성 연구)

  • 박종일;김경훈;정성일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.721-731
    • /
    • 1998
  • Recently, many researchers are studying the relation between thermal environment and human comfort. The purpose of this study was to obtain basic data which are necessary to determine the thermal comfort sensation and physiological responses for men in winter indoor environment. From January to February 1998, subject experiment was 40 times proceeded under twenty different conditions of air temperature and relative humidity with early-twenty male university students. We examined subjective evaluation, Electrocardiogram(ECG), Electroencephalogram(EEG) of subjects. The results of this study can be summarized as follows : The comfort zone of people in winter was achieved at Standard new effective temperature($SET^*$) $ 25.2^{\circ}C$, PMV range was obtained by Fanger's statistical calculation was -0.27<PMV<+0.62, TSV range obtained subjects vote was -0.76<TSV<+0.36. The largest difference of skin temperature was found at the calf area as air temperature changes. vote rate of human body presented calflongrightarrowheadlongrightarrowforearmlongrightarrowchestlongrightarrowabdo men in turn. Heart rate was decreased at low $SET^*$ and heart rate was increased at high $SET^*$ But there was no change at EEG.

  • PDF

An Experiment Study for Flame Spread Prevention System of Snadwich Panels (샌드위치 패널의 화재확대 방지시스템 개발을 위한 실험적 연구)

  • Shin, Hyun-Joon;In, Ki-Ho;Yoo, Yong-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.6
    • /
    • pp.307-312
    • /
    • 2015
  • The sandwich panel is commonly used domestically because it's less costly and easier to handle. But fires have frequently occurred in buildings employing sandwich panels, such as the fires in Eecheon cold storage and in Gwangju Pyungdong industrial zone. Sandwich panels with steel plates on their surface prevent fire water from penetrating to the fire source, which makes it difficult to extinguish a fire in a timely manner. Toxic gas generated from some insulation material leads to serious loss of life and property. This study is intended to develop an extinguishing system for sandwich panels, thereby reducing the fire risk. Fire water and volume were determined in the wake of the study on the structure of a sandwich panel extinguishing system, and improvement and testing of the fire characteristics of the sandwich panel. Based on such study and test, a fire model test was conducted. Consequently, the sandwich panel with extinguishing system was proven to have a reduced fire risk, compared to traditional or fire retardant panels.

An Experimental and Numerical Study on the Oxy-MILD Combustion at Pilot Scale Heating Capacity (Pilot급 산소 MILD 연소에 관한 실험 및 수치해석적 연구)

  • Cha, Chun-Loon;Lee, Ho-Yeon;Hwang, Sang-Soon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.275-282
    • /
    • 2016
  • MILD (Moderate and Intense Low-oxygen Dilution) combustion using oxygen as an oxidizer is considered as one of the most promising combustion technologies for high energy efficiency and for reducing nitrogen oxide and carbon dioxide emissions. In order to investigate the effects of nozzle angle and oxygen velocity conditions on the formation of oxygen-MILD combustion, numerical and experimental approaches were performed in this study. The numerical results showed that the recirculation ratio ($K_V$), which is an important parameter for performing MILD combustion, was increased in the main reaction zone when the nozzle angle was changed from 0 degrees to 15 degrees. Also, it was observed that a low and uniform temperature distribution was achieved at an oxygen velocity of 400 m/s. The perfectly invisible oxy-MILD flame was observed experimentally under the condition of a nozzle angle of $10^{\circ}$ and an oxygen velocity of 400 m/s. Moreover, the NOx emission limit was satisfied with NOx regulation of less than 80 ppm.

Analysis of Heating Energy in a Korean-Style Apartment Building 1: The Effect of Location (한국형 아파트의 난방에너지 분석 1: 위치의 영향)

  • 유호선;현석균;박유원;김용식;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.101-110
    • /
    • 2004
  • This paper presents an analysis of heating energy for apartment houses in a Korean-style apartment building, paying special attention on the effect of their location. Six representative locations encompass three floors and two placements on each floor. Two different roof types are also considered. In order to incorporate actual tenant's refit, a five-zone model composed of one conditioned and four unconditioned spaces is developed. TRNSYS 15 is adopted to estimate heating energy. The predicted results show fairly good agreements with the available measured data, validating the present model. Heating energy needed for an apartment located at the uppermost and lowermost floors is far greater compared with the case of intermediate floors. In addition, an appreciable difference is found between apartment with and without side end wall. Insulation thickness of walls, floors and underground structure appears to be a dominant factor affecting heating energy, which leads to needs of revision of the related regulation. Ridged-roofs instead of flat-roofs are highly recommended in apartment buildings for effective energy saving. It is finally concluded that the location-dependent, severe imbalance in heating energy should be improved and/or reflected in the policy making process and design standards.

A Study on Verification for the Design of Bio Safety Level 3 Laboratory by using Multi-zone Simulation (멀티죤 시뮬레이션을 이용한 생물안전 3등급(BSL3)시설의 설계 검증에 관한 연구)

  • Lee, Hyun-Woo;Choi, Sang-Gon;Hong, Jin-Kwan
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.745-750
    • /
    • 2009
  • In Korea, since the implementation of the GMO Law, the intrest of biosafety level 3(BL3) lab. is increasing. In this study, using CONTAM which is applying multizone modelling, the multizone simulation for design verification of BL3 lab. was performed. In BL3 lab., because required air change rate is greater than general estimated air-conditioning load and it is difficult to maintain room pressure difference efficiently, to maintain pressure difference between laboratory rooms is important through sealing condition of doors and proper airflow control of laboratory rooms. In this study, about BL3 lab.(M. tuberculosis research lab.), the multizone simulation for four kind of biohazard scenarios was performed in the case of unexpected spread of contaminants in the laboratory room, anteroom, corridor and inside of BSC. Multizone simulation results show that these approach methods are used as a tool for the design and verification of BL3 lab.

  • PDF

Effects of Temperature and Relative Humidity on the Physical Properties of Electronic Copying Paper (온·습도 조건이 전자 복사용지의 물리적 특성에 미치는 영향)

  • Kang, Kwang-Ho;Kim, Hyoung-Jin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.3
    • /
    • pp.70-78
    • /
    • 2012
  • For evaluating the printing suitability of electronic copying papers in the aspect of climate conditions, 12 samples of copying papers being generally used in Korea and worldwide were collected. The copying papers were controlled by various temperature and humidity options in conditioning equipment in order to simulate the specific circumstances of dry, temperate or tropical climate, and the pre-heating system of photocopying machines during printing. As results, some copying papers showed several physical problems, especially in recycled copying papers and a normal paper with original printing faulty. These problems of copying papers were mostly resulted in extremely high moisture circumstance, and in lower levels of tensile strength and tensile stiffness. The moisture contents of copying papers during passing through the pre-heater system of photocopying machine could be rapidly decreased because paper is exposed to high temperature around the pre-heating zone. The copying paper, for example of XR3 sample, containing low moisture contents below 2% had high exfoliating possibility of toner transfer from copying paper.

A Study on the Prediction of Indoor Environment in Bio Safety Level 3 Laboratory According to Biohazard Scenario (생물안전 3등급(BSL3)시설의 생물재해 시나리오에 따른 실내 공기환경예측에 관한 연구)

  • Park, Hyun-Jin;Hong, Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.745-750
    • /
    • 2010
  • Since the implementation of the LMO Law in Korea, the importance of the design qualification of BSL3 lab. is emphasizing. In this study, multizone simulation for three kind of biohazard scenarios using CONTAM is performed for design qualification of BSL3 lab. Also, in the case of unexpected spread of contaminants such as Influenza A virus(H1N1) in BL3 zone, the design qualification is carried out for diffusion and decontamination of contaminants according to differential pressure of BSL3 anteroom and door area of BSL3 lab. Also, in this study, appropriateness of laboratory room differential pressure and air flow rate to maintain pressure difference between laboratory rooms, and energy consumption due to air change rate variation according to door area in BL3 lab. Simulation results show that these approach methods are used as a tool for the design and verification of BL3 lab.