• 제목/요약/키워드: zeta-potential

검색결과 609건 처리시간 0.024초

마이크로 채널 내부 전기삼투 유속 측정을 통한 유리표면의 Zeta-potential 측정 (Zeta-potential Measurement on Glass Surface by Measuring Electro-osmotic Velocity inside a Micro-channel)

  • 한수동;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2005년도 추계학술대회 논문집
    • /
    • pp.80-84
    • /
    • 2005
  • Many important properties in colloidal systems are usually determined by surface charge ($\zeta$-potential) of the contacted solid surface. In this study, $\zeta$-potential of glass $\mu$-channel was evaluated from the electro-osmotic velocity distribution. The electro-osmotic velocity inside a glass $\mu$-channel was measured using a micro-PIV velocity field measurement technique. This evaluation method is more simple and easy to approach, compared with the traditional streaming potential technique. The $\zeta$-potential in the glass $\mu$-channel was measured for two different mole NaCl solutions. The effect of an anion surfactant, sodium dodecyl sulphate (SDS), on the electro-osmotic velocity and $\zeta$-potential in the glass surface was also studied. In the range of $0\∼6$mM, the surfactant SDS was added to NaCl solution in four different mole concentrations. As a result, the addition of SDS increases $\zeta$-potential in the surface of the glass $\mu$-channel. The measured $\zeta$-potential was found to vary from-260 to-70mV. When negatively charged particles were used, the flow direction was opposite compared with that of neutral particles. The $\zeta$-potential has a positive sign for the negative particles.

  • PDF

마이크로 채널 내부 전기삼투 유동의 Zeta-potential 계측 (Measurement of Zeta-potential of Electro-osmotic Flow Inside a Micro-channel)

  • 한수동;이상준
    • 대한기계학회논문집B
    • /
    • 제30권10호
    • /
    • pp.935-941
    • /
    • 2006
  • Many important properties in colloidal systems are usually determined by surface charge $({\zeta}-potential)$ of the contacted solid surface. In this study, ${\zeta}-potential$ of glass ${\mu}-channel$ was evaluated from the electro-osmotic velocity distribution. The electro-osmotic velocity inside a glass f-channel was measured using a micro-PIV velocity field measurement technique. This evaluation method is more simple and easy to approach, compared with the traditional streaming potential technique. The ${\zeta}-potential$ in the glass ${\mu}-channel$ was measured fur two different mole NaCl solutions. The effect of an anion surfactant, sodium dodecyl sulphate (SDS), on the electro-osmotic velocity and f-potential in the glass surface was also studied. In the range of $0{\sim}6mM$, the surfactant SDS was added to NaCl solution in few different mole concentrations. As a result, the addition of SDS increases ${\zeta}-potential$ in the surface of the glass ${\mu}-channel$. The measured $\zeta-potential$ was found to vary from -260 to -70mV. When negatively charged particles were used, the flow direction was opposite compared with that of neutral particles. The ${\zeta}-potential$ has a positive sign for the negative particles.

Characteristics of Zeta Potential Distribution in Silica Particles

  • Kim, Jin-Keun;Lawler, Desmond F.
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권7호
    • /
    • pp.1083-1089
    • /
    • 2005
  • Most experimental studies available in the literature on filtration are based on observed average zeta potential of particles (usually 10 measurements). However, analyses of data using the average zeta potential alone can lead to misleading and erroneous conclusions about the attachment behavior because of the variation of particle zeta potentials and the heterogeneous distribution of the collector surface charge. To study characteristics of zeta potential, zeta potential distributions (ZPDs) of silica particles under 9 different chemical conditions were investigated. Contrary to many researchers’ assumptions, most of the ZPDs of silica particles were broad. The solids concentration removal was better near the isoelectric point (IEP) as many researchers have noticed, thus proper destabilization of particles is very important to achieve better particle removal in particle separation processes. While, the mean zeta potential of silica particles at a given coagulant dose was a function of particle concentration; the amount of needed coagulant for particle destabilization was proportional to the total surface charge area of particles in the suspension.

점토와 조류입자의 제타전위가 부상분리 효율에 미치는 영향 (Effect of Zeta Potential of Clay and Algae Particles on Flotation Efficiency)

  • 최도영;김성진;정흥조;이세일;백도현;이재욱;곽동희
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.437-445
    • /
    • 2005
  • Zeta potential is a key parameter of double layer repulsion for individual particles and can usually be used to interpret the trend of coagulation efficiency. This study focused on the measurement of zeta potential of algae and clay under various experimental conditions including water characteristics (pure water, stream water, reservoir water) and coagulant dose (10~50 mg/L). Results showed that the variation of zeta potential was highly sensitive depending on the water characteristics and coagulation conditions. Zeta potential of two genera of algae (anabaena sp. and microcystis sp.) were changed highly with coagulant dosage, especially. On the basis of trajectory analysis, bubble-floc collision efficiency simulated in terms of zeta potential was fitted well with removal efficiency of chlorophyll-a from algae particles. It was found that the control of zeta potential was important for effective removal of algae particles.

(+)-Dihydromyricetin 분별침전에 미치는 제타전위의 영향 (Influence of Zeta Potential on Fractional Precipitation of (+)-Dihydromyricetin)

  • 하건수;김진현
    • Korean Chemical Engineering Research
    • /
    • 제53권6호
    • /
    • pp.831-835
    • /
    • 2015
  • 본 연구에서는 바이오매스 유래 생리활성물질인 (+)-dihydromyricetin을 정제하기 위한 분별침전공정에서 분별침전용액의 제타전위가 분별침전 양상(순도, 수율, 침전물 형태와 크기)에 미치는 영향을 조사하였다. 제타전위 조절을 위한 실리카-알루미나의 첨가량(반응액 부피당 표면적) $100mm^{-1}$에서 가장 높은 수율을 얻을 수 있었다. 실리카-알루미나의 제타전위가 양(+)의 값으로 증가할수록 (+)-dihydromyricetin 수율과 침전물의 크기는 증가하였다. 가장 큰 제타전위 값(+4.99 mV)을 가진 실리카를 이용한 분별침전의 경우에는 가장 작은 제타전위 값(-19.00 mV)을 가진 알루미나를 이용한 분별침전의 경우보다 2배 이상 높은 수율을 얻을 수 있었다. 또한 분별침전 과정에서 제타전위 절대값이 증가할수록 (+)-dihydromyricetin 수율과 침전물의 크기는 감소하여 제타전위 절대값에 반비례함을 알 수 있었다. 반면 표면적증가물질 실리카-알루미나의 제타전위 변화에도 (+)-dihydromyricetin 순도는 거의 변화가 없었다.

중공사막 외부표면의 제타전위 측정방법 고찰 (Measurements and methods for analyzing zeta potential of the external surface of hollow fiber membranes)

  • 이태섭;이상엽;이주희;홍승관
    • 상하수도학회지
    • /
    • 제23권3호
    • /
    • pp.353-362
    • /
    • 2009
  • A new method and equipment for measuring the zeta potential of the external surface of hollow fiber (HF) membranes is reported. An existing commercial streaming potential analyzer in conjunction with home-made test cells was used to determine the electrokinetic surface characteristics of various HF membranes. It was shown that measurements of the external surface of HF membrane using the home-made test cells designed in this study were easy and reliable. The zeta potential values were quite accurate and reproducible. By varying the physical shape of the test cells to adjust hydrodynamics inside the test cells, several upgrade versions of home-made test cells were obtained. It was shown that the zeta potential of the external surface of HF membranes was most influenced by membrane materials as well as the way of surface modification. However, the overall surface charge of tested HF membranes were much less than that of commercial polyamide thin-film-composite (TFC) reverse osmosis (RO) membranes due to the lack of surface functional groups. For the HF membranes with the same material, the effect of pore size on the zeta potential was not significant, implying the potential of accurate zeta potential measurements for various HF membranes. The results obtained in this study are expected to be useful for better understating of electrokinetic surface characteristics of the external surface of HF membranes.

중금속 오염 점성토의 전기삼투 배수와 제타포텐셜의 상관성 (The Relationship between Electroosmotic Drainage and Zeta Potential of Contaminated Clayey Soil with Heavy Metal)

  • 임성철;한상재;김정환;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.455-460
    • /
    • 2000
  • This research is about the relationship of electroosmotic drainage and zeta potential. Two laboratory experiments were conducted, at first a constant 16 voltage was applied to the cylindrical consolidated specimen of 10cm in diameter, 16cm in length at the concentration of 0, 500, 3000ppm Pb(II) and electroosmotic flow was measured for 12days. Then, zeta potential of kaolinite suspension was measured at the same concentration of electroosmotic permeability experiments in the range of pH from 2 to 14. From the result of this study, it was shown that zeta potential was dependent on the concentration of electrolyte and pH, was proportional to coefficient of electroosmotic permeability. According to the compared result of electroosmotic drainage, as the concentration of Pb(II) was low, the negative value of zeta potential was high and electroosmotic total flow was much.

  • PDF

입자 영상 처리 시스템을 이용한 콜로이드 입자의 제타포텐셜 측정 및 나노유체 분산 특성 연구 (A Study on the Zeta Potential Measurement and the Stability Analysis of Nano Fluids using a Particle Image Processing System)

  • 이재근;김성찬;김희중;이창건;주찬홍;이래철
    • 한국분무공학회지
    • /
    • 제8권1호
    • /
    • pp.16-22
    • /
    • 2003
  • Zeta potential measurements of colloid particles suspended in a liquid are performed by a Zeta Meter developed. There are many applications of colloid stability in spray technology, paints, wastewater treatment, and pharmaceuticalse. Zeta potentials of charged particles are obtained by measuring the electrophoretic velocities of the particles using video enhanced microscopy and image analysis program. The values of zeta potential of polystyrene latex(PSL), $silica(SiO_2)$M, polyvinylidence difluoride(PVDF), silicon nitride, and alumina particles in deionized (DI) water were measured to be -40.5, -31.9, -25.2, -15.1 and -10.1mV, respectively. The particles having high zeta potential less than -20 mV are stable in DI water, because the double layers of them have strong repulsive forces mutually, and the particles having low zeta potential over -20mV are unstable due to Van Der Waals forces. Silica(>20nm), PSL, aluminum and PVDF particles were found to be stable that would remain separate and well disperse, while silicon nitride and alumina particles were found to be unstable that would gradually agglomerate in DI water.

  • PDF

Effect of Zeta-Potential on the Viscosity of Clay-Water Suspension

  • Lee, Young-Seek;Ree, Jong-Baik;Ree, Taik-Yue
    • Bulletin of the Korean Chemical Society
    • /
    • 제3권3호
    • /
    • pp.83-88
    • /
    • 1982
  • Viscosity and zeta-potential of 11.0 wt. % aqueous bentonite suspension containing various electrolytes and hydrogen-ion concentration were measured by using a Couette type automatic rotational viscometer and Zeta Meter, respectively. The effects of pH and elcctrolytes on the rheological properties of the suspension were investigated. A system, which has a large zeta-potcntial, has a small intrinsic relaxation time ${\beta}$ and a small intrinsic shear modulus $1/{\alpha}$ in the Ree-Eyring generalized viscosity equation, i.e., such a system has a small viscosity value, since ${\eta}={\beta}/{\alpha}$. In general, a stable suspension system has large zeta-potential. The stability condition of clay-water suspension can be estimated by viscometric method since stable suspension generally has small viscosity. The correlation between the stability, viscosity and zeta-potential has been explained by the Ree-Eyring theory of viscous flow.

지료의 제타전위 측정을 통한 형광증백제의 흡착 평가 (Adsorption Analysis of Fluorescent Whitening Agent on Cellulosic Fibers by Zeta Potential Measurement)

  • 이지영;김은혜;김철환;박종혜
    • 펄프종이기술
    • /
    • 제47권6호
    • /
    • pp.106-112
    • /
    • 2015
  • Many researchers have proposed analytical methods to measure the adsorption of di-sulpho fluorescent whitening agents (D-FWAs), but practical methods for D-FWA utilization in an actual paper mill have not been established. In particular, the D-FWA adsorption behavior must be monitored in paper mills to ensure the effective use of D-FWAs. This study used the zeta-potential of pulps as an indicator of the adsorption behavior of a D-FWA. We identified the relationship between the actual adsorption of the D-FWA and the zeta-potential of the pulps as a function of D-FWA addition. zeta-potential measurements were then used to analyze the D-FWA adsorption behavior under different conditions of pulp type, conductivity, and pH. The actual adsorption of a D-FWA was proportional to the ${\Delta}zeta-potential$ of the pulps (i.e., the difference between the zeta-potential of a pulp containing no D-FWA and one containing the D-FWA). The ${\Delta}zeta-potential$ of the pulps was therefore adopted for adsorption analysis. A higher adsorption of the D-FWA was observed onto Hw-BKP than onto Sw-BKP because of the shorter fiber length and higher fines content of Hw-BKP. A high conductivity and an acidic pH decreased the D-FWA adsorption because of direct effects of high ion concentrations and low pH on the D-FWA solubility. Therefore, a D-FWA must be added to Hw-BKP under low conductivity conditions and at neutral or alkaline pH to optimize the D-FWA adsorption.