• Title/Summary/Keyword: zero-voltage switching

Search Result 854, Processing Time 0.026 seconds

새로운 2상 Switched Reluctance Motor용 Zero-Voltage Switching Converter

  • Kim, Hyeong-Jun;Lee, Geun-Hong;Sin, Hong-Cheol;Kim, Byeong-Han;Yun, Hui-Su;Bae, Han-Gyeong
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.291-292
    • /
    • 2012
  • 본 논문에서는 고속회전 모터응용을 위한 새로운 2상 SRM용 ZVS 컨버터를 제안한다. 제안한 컨버터는 모든 스위치에서 Zero-Voltage Switching이 가능하고, 기존 토폴로지에 비해 소자수가 작으며, 각 상간의 자연스러운 에너지 전달에 의해 토크 리플을 줄일 수 있다. 제안하는 컨버터의 동작원리를 설명하였고 기존 컨버터와의 비교 분석을 수행하였으며 시뮬레이션을 통해 본 방식의 타당성을 검증하였다.

  • PDF

A ZCT PWM Boost Converter using parallel MOSFET switch (병렬 MOSFET 스위치를 이용한 ZCT PWM Boost Converter)

  • Kim Tea-Woo;Hur Do-Gil;Kim Hack-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.759-762
    • /
    • 2002
  • A ZCT(Zero Current Transition) PWM(Pulse-Width-Modulation) boost converter using parallel MOSFET switch is proposed in this paper. The IGBT(main switch) of the proposed converter is always turned on with zero current switching and turned off with zero current/zero voltage switching. The MOSFET(auxiliary switch) is also operates with soft switching condition. In addtion to, the proposed converter eliminates the reverse recovery current of the freewheeling diode by adding the resonant inductor, Lr, in series with the main switch. Therefore, the turn on/turn off switching losses of switches are minimized and the conduction losses by using IGBT switch are reduced. In addition to, using parallel MOSFET switch overcomes the switching frequency limitation occurred by current tail. As mentioned above, the characteristics are verified through experimental results.

  • PDF

Single-Phase converter with partial resonant circuit (단상 컨버터의 부분공진 회로)

  • Lee, Hyun-Woo;Kwak, Dong-Kurl
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.129-131
    • /
    • 1993
  • Power conversion system of high performance requires high switching frequency power converter. In order to minimize commutation stress and switching losses, in this paper, AC-DC converter is embedded a partial resonant DC-Link circuit with the object of ZVCS(zero voltage switching and zero current switching). The partial resonant occurs just before converter switch operates. Thus, VA ratings of the elements and their dissipations due to effective series resistance (ESR) are very low. Some simulative results on computer are included to confirm the validity of the analytical results.

  • PDF

Suppression of Zero Sequence Current Caused by Dead-time for Dual Inverter With Single Source (단전원 듀얼 인버터의 데드타임으로 인한 영상전류 억제 방법)

  • Yoon, Bum-Ryeol;Kim, Tae-Hyeong;Lee, June-Hee;Lee, June-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.2
    • /
    • pp.126-133
    • /
    • 2022
  • This study proposes a suppression of zero sequence current (ZSC), which is caused by zero sequence voltage (ZSV) for a dual two-level inverter with single DC bus. Large output voltages enable the dual inverter with single DC bus to improve a system efficiency compared with single inverter. However, the structure of dual inverter with single DC bus inevitably generates ZSC, which reduces the system efficiency and causes a current ripple. ZSV is also produced by dead time, and its magnitude is determined by the DC bus and current direction. This study presents a novel space vector modulation method that allows the instantaneous suppression of ZSC. Based on a condition where a switching period is twice a sampling (control) period, the proposed control method is implemented by injecting the offset voltage at the primary inverter. This offset voltage is injected in half of the switching period to suppress the ZSC. Simulation and experiments are used to compare the proposed and conventional methods to determine the ZSC suppression performance.

A Study on the ZVS-CV Converter Using Thin-Film Inductor (박막 인덕터를 이용한 ZVS-CV 컨버터에 관한 연구)

  • Im, Sang-Un;Kim, Young-Jae;Kim, Hee-Jun;Kim, Hyoung-June
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2522-2525
    • /
    • 1999
  • Buck converter is considered to be one of the most widely used DC-DC converters due to its simple structure and high reliable performance. However, when it be combined with thin-film inductor, its own low inductance requires higher switching frequency in order to maintain optimum output ripple voltage and thus gives rise to extra switching losses. In view to overcoming such a technical in-convenience, soft switching fashion is suggested such as zero-voltage-switching of which an well known example is a Zero-Voltage-Switching clamp voltage(ZVS-CV) converter for which low inductance is imperatively required for ZVS operation. In order to support our suggestion, a 1W of ZVS-CV buck converter( Vo=3.3V, Iomax=0.3A, fs= 1.2MHz) is built by use of thin-film inductor, and then tested for comparing the measured efficiency between ours and conventional one. As the our results. the efficiency is improved about 2% at full load by the application of our concept.

  • PDF

Multi-Phase Interleaved ZVT Boost Converter With a Single Soft-Switching Cell (단일 소프트 스위칭 셀을 가진 다상 Interleaved ZVT Boost 컨버터)

  • Lee, Joo-Seung;Hwang, Yun-Seong;Kang, Sung-Hyun;Kwon, Man-Jae;Jang, Eunsu;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.3
    • /
    • pp.247-255
    • /
    • 2022
  • This paper proposes a multiphase interleaved zero-voltage-transition boost converter with a single soft-switching cell for high-voltage DC-DC converter (HDC) of fuel cell systems. The proposed single soft-switching cell structure can reduce the system volume by minimizing the passive and active elements added even in the multiphase-interleaved structure. To analyze the feasibility of the proposed structure, this paper mathematically analyzes the operation modes of the converter with the proposed single soft-switching cell structure and presents guidelines for design and considerations. In addition, the feasibility of the 210[kW] HDC was confirmed through PSIM simulation, and the system volume reduction of up to 10.48% was confirmed as a result of the 5[kW] HDC test-bed experiment considering the fuel cell system. Through this, the validity of the proposed structure was verified.

A New partial resonant buck-boost AC-DC converter for high power factor (부분공진형 고역률 승강압 AC-DC 컨버터)

  • Shin, Hyun-Sik;Suh, Ki-Young;Kwon, Soon-Kurl;Kwak, Dong-Kurl;Lee, Hyun-Woo;Woo, Jung-In
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.512-515
    • /
    • 1994
  • This paper propose the high power factor and efficiency buck-boost AC-DC converter because the input current is made sinusoidal wave in single phase alternating current source. The proposed converter is able to minimize switching loss by the partial resonant switching which is for switching devices to operate the zero voltage switching (ZVS) or zero current switching(ZCS) without increasing their voltage and current stresses.

  • PDF

A Novel Soft-Switching Full-Bridge PWM Converter with an Energy Recovery Circuit

  • Lee, Dong-Young;Cho, Bo-Hyung;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.809-821
    • /
    • 2009
  • This paper proposes a new phase-shift full-bridge DC-DC converter by applying energy recovery circuits to a conventional full-bridge DC-DC converter in plasma display panel applications. The converter can achieve soft-switching in main-switches by an extra auxiliary resonant network even with the wide operating condition of both output load and input voltage. The un-coupled design guidelines to the main bridge-leg component parameters for soft-switching operation contribute to conduction loss reduction in the transformer primary side leading to efficiency improvement. The auxiliary switches in the resonant network also operate in zero-current switching. This paper analyzes the operation modes of the proposed scheme and presents the key design guidelines through steady state analysis. Also, the paper verifies the validity of the circuits by hardware experiments with a 1kW DC/DC converter prototype.

Quasi Resonant DC Link Inverter with a Simple Auxiliary Circuit

  • Amini, Mohammad Reza;Farzanehfard, Hosein
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.10-15
    • /
    • 2011
  • In this paper, a new soft switching three phase inverter with a quasi-resonant dc-link is presented. The proposed inverter has a dc-link switch and an auxiliary switch. The inverter switches are turned on and off under zero voltage switching condition and all auxiliary circuit switches and diodes are also soft switched. The control utilizes PWM and the auxiliary switch does not require an isolated gate drive circuit. In this paper, the operation analysis and design considerations of the proposed soft switching inverter are discussed. The presented experimental results of a realized prototype confirm the theoretical analysis.

1.2KW PEM(Proton Exchange Membrane) System Full Bridge Phase Shift ZVS(Zero Volt Switching) DC-DC Converter Design and control (1.2KW 고분자 전해질 연료전지 시스템용 Full Bridge Phase Shift ZVS(Zero Volt Switching)을 적용한 DC-DC 컨버터의 설계 및 제어)

  • Seo, Jung-Wook;Park, Seung-Kyu;Ahn, Ho-Kyun;Kwak, Gun-Puyng
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1057-1058
    • /
    • 2006
  • In this paper, the proposed power supply is based on a modified version of the zero-voltage switching(ZVS) full-bridge phase-shift DC-DC converter, which incorporates commutation auxiliary inductors to provide ZVS for the entire load range as well as a commutation aid circuit to clamp the output diode voltage. The control strategy is based on two control loops operating in cascade mode. The complete operating principles and simulation results in presented.

  • PDF