• 제목/요약/키워드: zero-rating

검색결과 67건 처리시간 0.022초

A Simple ZVT PWM Single-Phase Rectifier with Reduced Conduction Loss and Unity Power Factor

  • Kim, In-Dong;Choi, Seong-Hun;Nho, Eui-Cheol;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • 제7권1호
    • /
    • pp.55-63
    • /
    • 2007
  • This paper proposes a simple unity power factor zero-voltage-transition (ZVT) pulse-width-modulated (PWM) single-phase rectifier, which features reduced switching and conduction losses. The switching loss reduction is achieved by a simple auxiliary commutation circuit, and the conduction loss reduction is achieved by employing a single-stage converter, rather than a typical double-stage converter comprising of a front-end rectifier and a boost rectifier. Furthermore, thanks to good features such as a simple PWM control at constant frequency, low switch stress, low Var rating of commutation circuits, and simple power circuit structure, it is suitable for high power applications. The principles of operation are explained in detail, and a major characteristics analysis and the experimental results of the new converter are also included in this paper.

Full ZVS Load Range Diode Clamped Three-level DC-DC Converter with Secondary Modulation

  • Shi, Yong
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.93-101
    • /
    • 2016
  • A new four-primary-switch diode clamped soft switching three-level DC-DC converter (TLDC) with full zero-voltage switching (ZVS) load range and TL secondary voltage waveform is proposed. The operation principle and characteristics of the presented converter are discussed, and experimental results are consistent with theoretical predictions. The improvements of the proposed converter include a simple and compact primary structure, TL secondary rectified voltage waveform, wide load range ZVS for all primary switches, and full output-regulated range with soft switching operation. The proposed converter also has some disadvantages. The VA rating of the transformer is slightly larger than that of conventional TLDCs in variable input and constant output mode. The conduction loss of the primary coil is slightly higher because an air gap is inserted into the magnetic cores of the transformer. Finally, the secondary circuit is slightly complex.

Half-Bridge Zero Voltage Switching Converter with Three Resonant Tanks

  • Lin, Bor-Ren;Lin, Wei-Jie
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.882-889
    • /
    • 2014
  • This paper presents a zero voltage switching (ZVS) converter with three resonant tanks. The main advantages of the proposed converter are its ability to reduce the switching losses on the power semiconductors, decrease the current stress of the passive components at the primary side, and reduce the transformer secondary windings. Three resonant converters with the same power switches are adopted at the low voltage side to reduce the current rating on the transformer windings. Using a series-connection of the transformer secondary windings, the primary side currents of the three resonant circuits are balanced to share the load power. As a result, the size of both the transformer core and the bobbin are reduced. Based on the circuit characteristics of the resonant converter, the power switches are turned on at ZVS. The rectifier diodes can be turned off at zero current switching (ZCS) if the switching frequency is less than the series resonant frequency. Therefore, the reverse recovery losses on the rectifier diodes are overcome. Experiments with a 1.6kW prototype are presented to verify the effectiveness of the proposed converter.

GSRS에 근거한 천식증상환자 중의 소화기증상 및 과거력에 대한 조사 (GSRS(Gastrointestinal Symptom Rating Scale)-Based Investigation about Gastrointestinal Symptoms and Histories in Patients with Asthmatic Symptoms)

  • 이재성;정승연;이건영;최준용;정희재;이형구;정승기
    • 대한한의학회지
    • /
    • 제25권1호
    • /
    • pp.198-204
    • /
    • 2004
  • Backgrounds & Methods : Asthma is considered to be chronic inflammatory disease characterized by airway hyperresponsiveness and pulmonary eosinophilia. Recently, there has been many researches about asthma. IBS(Irritable Bowel Syndrome), PUD(peptic Ulcer disease) and GERD(gastroesophageal reflux disease) are the most common diseases of the gastrointestinal tract. Recent studies suggest that IBS, PUD and GERD are associated with bronchial hyper-responsiveness and bronchial asthma might be more prevalent in IBS and GERD patients than in control subjects. In addition, there are many comments about the interrelationship between the gastrointestinal problem and asthma in the oriental medical books. Actually, many oriental medical doctors don$^{\circ}$Øt consider the gastrointestinal condition when they deal with the asthmatic patients these days. So, we assessed the prevalence of gastrointestinal symptoms and histories in a cohort of patients with asthmatic symptoms. We evaluated 128 outpatients with asthmatic symptoms(60 males and 68 females, aged 13-75). All subjects enrolled completed the GSRS(Gastrointestinal Symptom Rating Scale). GSRS is an interview based rating scale consisting of 15 items for assessment of gastrointestinal symptoms in IBS and PUD developed by Jan Svedlund. Results : The limit of total score of GSRS in asthmatic patients is zero to 30. The number of patients with no GI symptoms is 66(51.5%). The number of patients with GSRS>5 is 62(48.4%), GSRS>10 is 24(18.8%), GSRS>15 is 8(6.25%). The number of patients with history of gastritis is 54(42.2%), gastric ulcer is 13(10.2%), gastroptosis is 8(6.25%), IBS is 6(4.68%), others is 6(4.68%). Conclusions : This study suggests that patients with bronchial asthma have an significant prevalence of gastrointestinal symptoms. Additional studies are needed to find the mechanism of the association between gastrointestinal symptoms and asthma.

  • PDF

Design and Control of Novel Topology for Photovoltaic DC/DC Converter with High Efficiency under Wide Load Ranges

  • Lee, Jong-Pil;Min, Byung-Duk;Kim, Tae-Jin;Yoo, Dong-Wook;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.300-307
    • /
    • 2009
  • In this paper, design and control is proposed for a four input-series-output-series-connected ZVS full bridge converter for the photovoltaic power conditioning system (PCS). The novel topology for a photovoltaic (PV) DC/DC converter that can dramatically reduce the power rating and increase the efficiency of a PV system by analyzing PV module characteristics is proposed. The control scheme, including an input voltage controller is proposed to achieve equal sharing of the input voltage as well output voltages by a four series connected module. Design methods for ZVS power stage are also introduced. The total PV system is implemented for a 250-kW PV power conditioning system (PCS). This system has only three DC/DC converters with a 25-kW power rating and uses only one-third of the total PV PCS power. The 25-kW prototype PV DC/DC converter is introduced to verify experimentally the proposed topology. In addition, an experimental result shows that the proposed topology exhibits good performance.

Analysis and Implementation of a New Three-Level Converter

  • Lin, Bor-Ren;Nian, Yu-Bin
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.478-487
    • /
    • 2014
  • This study presents a new interleaved three-level zero-voltage switching (ZVS) converter for high-voltage and high-current applications. Two circuit cells are operated with interleaved pulse-width modulation in the proposed converter to reduce the current ripple at the input and output sides, as well as to decrease the current rating of output inductors for high-load-current applications. Each circuit cell includes one half-bridge converter and one three-level converter at the primary side. At the secondary side, the transformer windings of two converters are connected in series to reduce the size of the output inductor or switching current in the output capacitor. Based on the three-level circuit topology, the voltage stress of power switches is clamped at $V_{in}/2$. Thus, MOSFETs with 500 V voltage rating can be used at 800 V input voltage converters. The output capacitance of the power switch and the leakage inductance (or external inductance) are resonant at the transition interval. Therefore, power switches can be turned on under ZVS. Finally, experiments verify the effectiveness of the proposed converter.

도로터널 굴착공사의 적정공기 판단기준 (Optimum Construction Duration for Road Tunnel Excavation Works)

  • 김하나;김대영;김대영;정성춘;허영기
    • 대한건축학회논문집:구조계
    • /
    • 제34권4호
    • /
    • pp.59-64
    • /
    • 2018
  • Construction schedule acceleration due to unreasonable construction planning frequently leads to construction accidents. In order to avoid such inevitable acceleration and to ensure safety in construction sites, there is a need for objective standards to determine appropriate construction duration for each construction process earlier in the process. In order to achieve the goal, intensive experts interviews were firstly conducted to identify candidate drivers affecting construction schedule of road tunnel excavation works. Then, a total of 34 field data was collected from on-going sites to analyze. It was found that actual excavation length per one day on site is varied mostly by Rock Mass Rating(RMR) types from various statistical analyses. Therefore an one-way table of excavation length per a day by RMR types were presented in a form of percentile. The results will help industry experts determine the most appropriate construction schedule for the works, which eventually lead to a zero accident site in many ways.

New Three-Level PWM DC/DC Converter - Analysis, Design and Experiments

  • Lin, Bor-Ren;Chen, Chih-Chieh
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.30-39
    • /
    • 2014
  • This paper studies a new three-level pulse-width modulation (PWM) resonant converter for high input voltage and high load current applications. In order to use high frequency power MOSFETs for high input voltage applications, a three-level DC converter with two clamped diodes and a flying capacitor is adopted in the proposed circuit. For high load current applications, the secondary sides of the proposed converter are connected in parallel to reduce the size of the magnetic core and copper windings and to decrease the current rating of the rectifier diodes. In order to share the load current and reduce the switch counts, three resonant converters with the same active switches are adopted in the proposed circuit. Two transformers with a series connection in the primary side and a parallel connection in the secondary side are adopted in each converter to balance the secondary side currents. To overcome the drawback of a wide range of switching frequencies in conventional series resonant converters, the duty cycle control is adopted in the proposed circuit to achieve zero current switching (ZCS) turn-off for the rectifier diodes and zero voltage switching (ZVS) turn-on for the active switches. Finally, experimental results are provided to verify the effectiveness of the proposed converter.

A ZVS Resonant Converter with Balanced Flying Capacitors

  • Lin, Bor-Ren;Chen, Zih-Yong
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1190-1199
    • /
    • 2015
  • This paper presents a new resonant converter to achieve the soft switching of power devices. Two full-bridge converters are connected in series to clamp the voltage stress of power switches at Vin/2. Thus, power MOSFETs with a 500V voltage rating can be used for 800V input voltage applications. Two flying capacitors are connected on the AC side of the two full-bridge converters to automatically balance the two split input capacitor voltages in every switching cycle. Two resonant tanks are used in the proposed converter to share the load current and to reduce the current stress of the passive and active components. If the switching frequency is less than the series resonant frequency of the resonant tanks, the power MOSFETs can be turned on under zero voltage switching, and the rectifier diodes can be turned off under zero current switching. The switching losses on the power MOSFETs are reduced and the reverse recovery loss is improved. Experiments with a 1.5kW prototype are provided to demonstrate the performance of the proposed converter.

지열 열펌프 및 태양광 발전 적용이 비주거용 건물의 에너지효율등급과 ZEB 인증 등급에 미치는 영향 (The Effect of a Geothermal Heat Pump and Photovoltaics Application on the Building Energy Efficiency and ZEB Certification Rating for a Non-Residential Building)

  • 문건호;박창용
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권1호
    • /
    • pp.1-13
    • /
    • 2023
  • Many government in the world have conducted building energy performance certification program to reduce building energy consumption. In this study, a reference building and its HVAC system was modeled, and the energy load and consumption were estimated by the ECO2 program. The software is a simple building energy simulation program based on monthly calculated method. The building energy efficiency rating the the reference building was 1+ under baseline condition. The simulation results showed that the insulation performance slightly affected building energy load and consumption, but light density had a significant effect on them. The application of geothermal heat pumps gave improvement of building energy efficiency rating but it could not make it possible to get zero energy building(ZEB) certification. The ZEB 5 certification could be achieved by using photovoltaics, however getting better grade was difficult. The simulation results showed that the ZEB 4 certification, one grade higher than ZEB 5, could be attained by using more than one renewable energy source such as geothermal and solar energy in this study.