• Title/Summary/Keyword: zero curve

Search Result 213, Processing Time 0.028 seconds

A Study on Flame Extinction and Edge Flame Oscillation in Counterflow Diffusion Flame (대향류확산화염에서 화염소화와 에지화염진동에 관한 연구)

  • Park, Dae-Geun;Yun, Jin-Han;Park, Jeong;Keel, Sang-In
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.2
    • /
    • pp.64-76
    • /
    • 2009
  • Experimental and numerical studies are conducted on the characteristics of flame extinction and edge flame oscillation in counterflow diffusion flames. The characteristics of flame extinction and edge flame oscillation are well described varying burner diameter, separation distance between two burners, global strain rate, and velocity ratio. It is verified numerically and experimentally that radial conduction heat loss significantly contributes to flame extinction and edge flame oscillation at low strain rate flames in zero- and micro-gravity. It is also shown that for appropriately small burner diameters flame extinction modes are grouped into four and these are significantly attributed to excessive radial conduction heat loss. The edge flame oscillation can be characterized well by one curve with Strouhal number and Peclet number.

Preparations and Magnetic Properties of Aluminum Anodic Oxidized Films Electrodeposited Cobalt-Iron Alloys (코발트-철을 전해석출한 양극산화피막의 제작과 자기특성)

  • 강희우
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.1
    • /
    • pp.25-31
    • /
    • 1994
  • The magnetic properties of aluminum anodized film in which Co-Fe alloy electrodeposited are investigated with regard to the alloy composition of magnetic films. The electrodeposited Co-Fe particles are confirmed to be single phase Co-Fe alloys by X-ray diffractions. At 34 at% Co, the sample with small pore diameter(particle diameter $150\;{\AA}$) has a large magnetic energy product($B_{max}$) of about 1.44 MGOe due to the large saturation magnetization, the high coercive force and good squareness of the M-H curve. However, for the samples with particle diameter larger than $450\;{\AA}$, the bottom of each particle forms abnormal particle claaed branch-shaped unlike the sample of the particle diameter $150\;{\AA}$. In this case, the magnetic anisotropy energy was about zero at the compositions of 45 and 75 at% Co. Moreover, at the compositions from 50 to 70 at% Co, the anisotropy became negative value. This means that an easy axis of magnetization of the film is in plane in plane in spite of the perpendicular shape anisotropy of the particle. It was found that the bottom extremity of the particle contains FeC from the X-ray diffraction. Thus the effect of the bottom extremity, that is, an unusal magnetic property was removed by electrodepositing Cu at the bottom extremity of the particle. Itis clear that the magnetic properties of the ilms are influenced by he branch-shaped bottom extremity filled with FeC.

  • PDF

Geometric Processing for Freeform Surfaces Based on High-Precision Torus Patch Approximation (토러스 패치 기반의 정밀 근사를 이용한 자유곡면의 기하학적 처리)

  • Park, Youngjin;Hong, Q Youn;Kim, Myung-Soo
    • Journal of the Korea Computer Graphics Society
    • /
    • v.25 no.3
    • /
    • pp.93-103
    • /
    • 2019
  • We introduce a geometric processing method for freeform surfaces based on high-precision torus patch approximation, a new spatial data structure for efficient geometric operations on freeform surfaces. A torus patch fits the freeform surface with flexibility: it can handle not only positive and negative curvature but also a zero curvature. It is possible to precisely approximate the surface regardless of the convexity/concavity of the surface. Unlike the traditional method, a torus patch easily bounds the surface normal, and the offset of the torus becomes a torus again, thus helps the acceleration of various geometric operations. We have shown that the torus patch's approximation accuracy of the freeform surface is high by measuring the upper bound of the two-sided Hausdorff distance between the freeform surface and set of torus patches. Using the method, it can be easily processed to detect an intersection curve between two freeform surfaces and find the offset surface of the freeform surface.

2-D meso-scale complex fracture modeling of concrete with embedded cohesive elements

  • Shen, Mingyan;Shi, Zheng;Zhao, Chao;Zhong, Xingu;Liu, Bo;Shu, Xiaojuan
    • Computers and Concrete
    • /
    • v.24 no.3
    • /
    • pp.207-222
    • /
    • 2019
  • This paper has presented an effective and accurate meso-scale finite element model for simulating the fracture process of concrete under compression-shear loading. In the proposed model, concrete is parted into four important phases: aggregates, cement matrix, interfacial transition zone (ITZ), and the initial defects. Aggregate particles were modelled as randomly distributed polygons with a varying size according to the sieve curve developed by Fuller and Thompson. With regard to initial defects, only voids are considered. Cohesive elements with zero thickness are inserted into the initial mesh of cement matrix and along the interface between aggregate and cement matrix to simulate the cracking process of concrete. The constitutive model provided by ABAQUS is modified based on Wang's experiment and used to describe the failure behaviour of cohesive elements. User defined programs for aggregate delivery, cohesive element insertion and modified facture constitutive model are developed based on Python language, and embedded into the commercial FEM package ABAQUS. The effectiveness and accuracy of the proposed model are firstly identified by comparing the numerical results with the experimental ones, and then it is used to investigate the effect of meso-structure on the macro behavior of concrete. The shear strength of concrete under different pressures is also involved in this study, which could provide a reference for the macroscopic simulation of concrete component under shear force.

Ustekinumab pharmacokinetics after subcutaneous administration in swine model

  • Grabowski, Tomasz;Burmanczuk, Artur;Derlacz, Rafal;Stefaniak, Tadeusz;Rzasa, Anna;Borkowski, Jacek
    • Journal of Veterinary Science
    • /
    • v.22 no.5
    • /
    • pp.47.1-47.10
    • /
    • 2021
  • Background: Due to multiple similarities in the structure and physiology of human and pig skin, the pig model is extremely useful for biological drug testing after subcutaneous administration. Knowledge of the differences between subcutaneous injection sites could have a significant impact on the absorption phase and pharmacokinetic profiles of biological drugs. Objectives: This study aimed to analyze the impact of administration site on pharmacokinetics and selected biochemical and hematological parameters after a single subcutaneous administration of ustekinumab in pigs. Drug concentrations in blood plasma were analyzed by enzyme-linked immunosorbent assay. Pharmacokinetic analyses were performed based on raw data using Phoenix WinNonlin 8.1 software and ThothPro v 4.1. Methods: The study included 12 healthy, female, large white piglets. Each group received a single dose of ustekinumab given as a 1 mg/kg subcutaneous injection into the internal part of the inguinal fold or the external part of the inguinal fold. Results: The differences in absorption rate between the internal and external parts of the inguinal fold were not significant. However, the time of maximal concentration, clearance, area under the curve calculated between zero and mean residence time and mean residence time between groups were substantially different (p > 0.05). The relative bioavailability after administration of ustekinumab into the external part of the inguinal fold was 40.36% lower than after administration of ustekinumab into the internal part of the inguinal fold. Conclusions: Healthy breeding pigs are a relevant model to study the pharmacokinetic profile of subcutaneously administered ustekinumab.

Long-term simultaneous monitoring observations of SiO and H2O masers toward Mira variable WX Serpentis

  • Lim, Jang Ho;Kim, Jaeheon;Son, Seong Min;Suh, Kyung-Won;Cho, Se-Hyung;Yang, Haneul;Yoon, Dong-Hwan
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.49.1-49.1
    • /
    • 2021
  • We carried out simultaneous monitoring observations of five maser lines, H2O (22 GHz), SiO 𝝊 =1, 2, J =1-0 (43.1, 42.8 GHz), and SiO 𝝊 =1, J=2-1, J =3-2 (86.2, 129.3 GHz), toward the Mira variable star WX Serpentis with the 21-m antennas of the Korean VLBI Network (KVN) in 2009-2021 (~12 years). Most spectra of the H2O maser are well separated into two parts of two blue- and one redshifted features within ± 10 km s-1 of the stellar velocity. All detected SiO masers are generally concentrated within ± 5 km s-1 of the stellar velocity, and sometimes appear split into two components. Overall, the profiles of SiO and H2O masers detected in WX Serpentis illustrate typical characteristics of the Mira variable. In addition, flux variations of both SiO and H2O masers are well correlated with the optical light curve of the central star, showing a phase lag of ~ 0.1 for SiO masers and ~ 0.2 for H2O maser. This phenomenon is considered to be the direct effect of propagating shock waves generated by the stellar pulsation, because SiO and H2O masers are sequentially distributed at different positions with respect to the central star. In addition, we analyzed long-term trends and characteristics of maser velocities, maser ratio, and the velocity extents (the full width at zero power; FWZP). We also investigated a spectral energy distribution (SED) ranging from 1.2 to 240 ㎛ obtained using several infrared data: 2MASS, WISE, IRAS, ISO, COBE DIBRE, RAFGL, and AKARI (IRC and FIS). From the IRAS LRS and ISO SWS spectra of this star, we identified 9.7 and 12 ㎛ silicate emission features consistent with the SE6 spectrum model, corresponding to the typical AGB phase.

  • PDF

Landslide risk zoning using support vector machine algorithm

  • Vahed Ghiasi;Nur Irfah Mohd Pauzi;Shahab Karimi;Mahyar Yousefi
    • Geomechanics and Engineering
    • /
    • v.34 no.3
    • /
    • pp.267-284
    • /
    • 2023
  • Landslides are one of the most dangerous phenomena and natural disasters. Landslides cause many human and financial losses in most parts of the world, especially in mountainous areas. Due to the climatic conditions and topography, people in the northern and western regions of Iran live with the risk of landslides. One of the measures that can effectively reduce the possible risks of landslides and their crisis management is to identify potential areas prone to landslides through multi-criteria modeling approach. This research aims to model landslide potential area in the Oshvand watershed using a support vector machine algorithm. For this purpose, evidence maps of seven effective factors in the occurrence of landslides namely slope, slope direction, height, distance from the fault, the density of waterways, rainfall, and geology, were prepared. The maps were generated and weighted using the continuous fuzzification method and logistic functions, resulting values in zero and one range as weights. The weighted maps were then combined using the support vector machine algorithm. For the training and testing of the machine, 81 slippery ground points and 81 non-sliding points were used. Modeling procedure was done using four linear, polynomial, Gaussian, and sigmoid kernels. The efficiency of each model was compared using the area under the receiver operating characteristic curve; the root means square error, and the correlation coefficient . Finally, the landslide potential model that was obtained using Gaussian's kernel was selected as the best one for susceptibility of landslides in the Oshvand watershed.

Effect of Hypothermia on the Prevention of Ventilator-Induced Lung Injury in Rats (백서에서 저체온 전처치가 환기기유발폐손상 억제에 미치는 효과)

  • Lim, Chae-Man;Hong, Sang-Bum;Koh, Youn-Suck;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.5
    • /
    • pp.540-548
    • /
    • 2001
  • Backgrounds : Because ventilator-induced lung injury is partly dependent on the intensity of vascular flow, we hypothesized that hypothermia may attenuate the degree of such an injury through a reduced cardiac output. Methods : Twenty-seven male Sprague-Dawley rats were randomly assigned to normothermia ($37{\pm}1^{\circ}C$)-injurious ventilation (NT-V) group (n=10), hypothermia ($27{\pm}1^{\circ}C$)-injurious ventilation (HT-V) group (n=10), or nonventilated control group (n=7). The two thermal groups were subjected to injurious mechanical ventilation for 20 min with peak airway pressure 30 cm $H_2O$ at zero positive end-expiratory pressure, which was translated to tidal volume $54{\pm}6\;ml$ in the NT-V group and $53{\pm}4\;ml$ in the HT-V group (p>0.05). Results : Pressure-volume (P-V) curve after the injurious ventilation was almost identical to the baseline P-V curve in the HT-V group, whereas it was shifted rightward in the NT-V group. On gross inspection, the lungs of the HT-V group appeared smaller in size, and showed less hemorrhage especially at the dependent regions, than the lungs of the NT-V group. [Wet lung weight (g)/body weight (kg)] ($1.6{\pm}0.1$ vs $2.4{\pm}1.2$ ; p=0.014) and [wet lung weight/dry lung weight] ($5.0{\pm}0.1$ vs $6.1{\pm}0.8$ ; p=0.046) of the HT-V group were both lower than those of the NT-V group, while not different from those of the control group($1.4{\pm}0.4$, $4.8{\pm}0.4$, respectively). Protein concentration of the BAL fluid of the HT-V group was lower than that of the NT-V group($1,374{\pm}726\;ug/ml$ vs $3,471{\pm}1,985\;ug/ml$;p=0.003). Lactic dehydrogenase level of the BAL fluid of the HT-V group was lower than that of the NT-V group ($0.18{\pm}0.10\;unit/ml$ vs $0.43{\pm}0.22\;unit/ml$;p=0.046). Conclusions : Hypothermia attenuated pulmonary hemorrhage, permeability pulmonary edema, and alveolar cellular injuries associated with injurious mechanical ventilation, and preserved normal P-V characteristics of the lung in rats.

  • PDF

Bioequivalence of LesacinTM Tablet to Jeil CravitTM Tablet (Levofloxacin 100 mg) by Liquid Chromatography- Electrospray Tandem Mass Spectrometry (LC-MS/MS를 이용한 제일크라비트정(레보플록사신 100 mg)에 대한 레사신정 100 mg의 생물학적 동등성)

  • Lee, Jin-Sung;Choi, Sang-Jun;Ryu, Ju-Hee;Seo, Ji-Hyung;Lee, Myung-Jae;Kang, Jong-Min;Tak, Sung-Kwon;Kang, Jin-Yang;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • The purpose of the present study was to evaluate the bioequivalence of two levofloxacin tablets, Jeil $Cravit^{TM}$ tablet (Jeil Pharm. Co., Ltd., Korea, reference drug) and $Lesacin^{TM}$ tablet (Ilhwa. Co., Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty-four healthy male Korean volunteers received two tablets containing levofloxacin 200 mg in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of levofloxacin were monitored for over a period of 24 hr after administration by using a high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). The area under the plasma concentration-time curve from time zero to 24 hr ($AUC_t$), maximum plasma drug concentration ($C_{max}$) and time to reach $C_{max}\;(T_{max})$ were complied from the plasma concentration-time data. Analysis of variance (ANOVA) test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$ and $C_{max}$. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Lesacin^{TM}$/Jeil $Cravit^{TM}$ were $\log\;0.9527{\sim}\log\;0.9981$ and $\log\;0.8712{\sim}\log\;1.0556$, respectively. These values were within the acceptable bioequivalence intervals of $\log\;0.80{\sim}\log\;1.25$, recommended by KFDA. In all of these results, we concluded that $Lesacin^{TM}$ tablet was bioequivalent to Jeil $Cravit^{TM}$ tablet, in terms of rate and extent of absorption.

Pharmacokinetics of amikacin in plasma of healthy goats after intravenous injection once daily for three days

  • Naseem, Sania;Sultana, Mudasir;Raina, Rajinder;Pankaj, Nrip Kishore;Verma, Pawan Kumar;Nasir, Nasir Ahmad;Ahanger, Azad Ahmad;Rahman, Shafiqur;Prawez, Shahid
    • Korean Journal of Veterinary Research
    • /
    • v.51 no.4
    • /
    • pp.253-257
    • /
    • 2011
  • Amikacin is a semisynthetic derivative of kanamycin and primarily active against aerobic Gram-negative-pathogens with limited activity against Gram-positive bacteria. Meager study was reported on pharmacokinetic data on multi-days administration of amikacin. Hence, pharmacokinetics study was done in five clinically healthy goats (n = 5), after intravenous bolus injection of amikacin sulfate at the dose rate of 10 mg/kg body weight daily for three consecutive days. The amikacin concentrations in plasma and pharmacokinetics-parameters were analyzed by using microbiological assay technique and noncompartmental open-model, respectively. The mean peak plasma concentrations (Mean ${\pm}$ SD) of amikacin at time zero ($Cp^{0}$) was $114.19{\pm}20.78$ and $128.67{\pm}14.37{\mu}g/mL$, on day 1st and 3rd, respectively. The mean elimination half-life ($t_{1/2}ke$) was $1.00{\pm}0.28h$ on day 1st and $1.22{\pm}0.29h$ on day 3rd. Mean of area under concentration-time curve ($AUC_{0{\rightarrow}{\infty}}$) was $158.26{\pm}60.10$ and $159.70{\pm}22.74{\mu}g.h/mL$, on day 1st and 3rd respectively. The total body clearance ($Cl_{B}$) and volume of distribution at steady state (Vdss) on day 1st and 3rd were $Cl_{B}=0.07{\pm}0.02$ and $0.06{\pm}0.01L/h.kg$ and $Vdss=0.10{\pm}0.03$ and $0.11{\pm}0.05L/kg$, respectively. No-significant difference was noted in both drug-plasma concentration and pharmacokinetics-parameters, respectively. Amikacin concentration in plasma was found higher up-to 4 h and 6 h onward on down-ward trends favour to reduce toxicity. Which also support the pharmacokinetic-pharmacodynamic way of dosing of aminoglycosides and hence, amikacin may be administered 10 mg/kg intravenously daily to treat principally Gram-negative pathogens and limitedly Gram-positive-pathogens.