A design of transmission-type multi-target X-ray tube based on electric field modulation

  • Zhao, Lei;Jia, Wenbao;Jin, Limin;Shan, Qing;Cheng, Can;Zhu, Hongkui;Hei, Daqian
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3026-3034
    • /
    • 2021
  • Multi-target X-ray tube is a new type X-ray source, and can be applied in many fields such as sensitive X-ray fluorescence analysis and medical imaging. In this work, we report an electric field modulation multi-target X-ray tube, which contains four targets (Cr, Ni, Au, Mo) coated on a Beryllium (Be) window. A four-valve electric field deflector was developed to deflect the electron beam to bombard the corresponding targets. Particle dynamics analysis software was employed to simulate the particle tracking of electron beam. The results show that the 30 keV electron beam could get a 6.7 mm displacement on the target plane by 105 V/m electric field. The focus areas are about 2 mm × 5 mm and 4 mm × 2.5 mm after deflection in two directions. Thermal behavior calculated by ANSYS shows that the designed target assembly could withstand a 10 W continuous power. The optimum target thicknesses and emission spectra were obtained by Geant4 when the thickness of Be window was 300 mm and the electron beam incident angle was 0.141 rad. The results indicate that this multi-target X-ray tube could provide different X-ray sources effectively.

X-ray 갈비뼈 촬영에서 겨드랑이쪽의 골절된 갈비뼈 진단을 위한 촬영법 연구 (A Study Radiograph Techniques for Diagnosis of Axillary Fracture Ribs in X-ray)

  • 안병주;이준행
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.979-986
    • /
    • 2019
  • 본 연구는 Rib Rando Phantom을 이용하여 겨드랑 첫 번째, 두 번째 갈비뼈 골절이 선예하게 나타나는 영상의 검사방법을 연구하였다. 팬톰의 자세와 엑스선관 각도를 수직, 머리쪽 5°, 다리쪽 5°로 변경하여 검사하였다. 획득한 영상을 방사선사가 주관적으로 영상평가 하였으며, 평가 데이터를 SPSS ver. 3.0으로 분석하였다. ImageJ Program을 이용하여 신호대잡음비(SNR)를 계산하였다. 그 결과 Cronbach Alpha 값이 0.789로 유의하게 높았다. 신호대잡음비(SNR)의 결과는 갈비뼈 앞쪽의 경우 엑스선관을 머리쪽으로 5° 기울여 검사 시 6.038, 갈비뼈 뒤쪽의 경우 엑스선관을 다리쪽으로 5° 기울여 검사 시 7.860으로 가장 높았다. 겨드랑 갈비뼈의 촬영기법으로 앞쪽 검사는 골절된 부위를 거상하고 엑스선관 각도를 머리쪽으로 5° 주며, 뒤쪽 검사는 골절된 부위를 밀착하여 엑스선관 각도를 발쪽으로 5° 기울여 검사한다면 선예한 영상을 얻을 수 있을 것으로 사료된다.

X-ray 코곁굴 검사에서 위턱굴 진단을 위한 비극-두정방향 촬영법 개발 (Development of Acanthial Parieto Projection for Maxillary Diagnosis in X-ray Paranasal Sinuses)

  • 안병주;김용완;김인수
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.327-333
    • /
    • 2023
  • 본 연구는 X-Ray 단순 코곁굴 검사에서 위턱뼈와 위턱굴의 진단하고자 바로누운자세에서 부비동 비극-두정방향은 검사법 연구하였다. Skull Rando Phantom을 이용하여 자세와 엑스선관 각도를 변경하여 검사 후 영상의학과에서 10년 이상 근무한 방사선사 5명에게 주관적평가(ROC)를 의뢰한 결과 엑스선관을 머리쪽 또는 다리쪽을 향하여 5° 씩 기울려 검사 시 19점으로 높은 평가를 맞았다. 평가한 점수를 SPSS Ver. 3.0을 통해 유의성을 검증하였으며 Cronbach 값이 0.712로 유의하게 나타났다. 또한 위턱굴과 위턱뼈 영상의 관심영역(ROI)을 설정하여 SNR를 산출한 결과 엑스선관 머리쪽 또는 다리쪽 5° 씩 기울려 검사 시 6.449로 가장 높게 나타났다. 본 연구에서 X-Ray 단순검사의 코곁굴 검사에서 비극-두정방향(acanthi oparietal projection: Revesse Waters) 검사 시 엑스선관을 머리쪽 또는 다리쪽을 향하여 5° 씩 기울려 검사할 경우 선예한 영상을 얻을 수 있을 것으로 사료된다.

X선 진단영역 에너지 측정을 위한 Photo-Diode 선량계(PD-2000)의 개발 (The development of photo-diode dosimeter(PD-2000) for the diagnostic X-ray Energy)

  • 김성철;이우철;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.27-32
    • /
    • 2000
  • It was produced radiation dosimeter used photo-diodes for which ionization by x-ray was applied and evaluated the value of utility in clinics as compared with ion-chamber. The result obtained were as follows : 1. Comparison of ion-chamber with photo-diode dosimeter's x-ray output by the change of x-ray tube voltage, and the ratio of ion-chamber to diode was $0.96{\sim}1.02$ which was not affected by x-ray beam quality. 2. The ratio of ion-chamber to diode was 0.96 by change of tube current and 0.97 by change of exposure time that is not affected by x-ray quantity. 3. The ratio of ion-chamber to diode was $0.97{\sim}1.04$ by thickness and $0.93{\sim}1.10$ by radiation field that is little affected by second ray quantity. 4. Reproducibility of photo-diode dosimeter was 0.011(CV) and it is a good result. 5. Photo-diode dosimeter was affected by the surface angle of detector over 30 degrees. Produced dosimeter was small, light, and meets good result compared with ionization chamber. It was expected come into wide use in clinic.

  • PDF

척주측만증과 허리뼈 골절 수술 환자의 엑스선 촬영법 연구 (A Study of Radiographic Methods to X-ray Study of Patients with Spinal Scoliosis and Vertebrae Bone Fracture of Lumbar Spine)

  • 안병주;이준행
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.425-431
    • /
    • 2019
  • 본 연구자는 척주 측만증 및 허리뼈 분쇄 골절된 환자의 수술 후 단순 엑스선 척주 측방향 촬영에서 두개의 철심이 겹친 영상을 얻어내기 위해 엑스선관 및 인체팬톰의 각도를 변화시켜 영상을 얻었다. 영상 평가를 위해 대학병원 영상의학과에서 10년 이상 근무한 방사선사 5명에게 주관적 평가를 하였다. 측정 결과 척주 측만증 측방향 촬영은 정중 이마면을 IR면 중심에 일치되게 하고 일곱 번째 등뼈가 중앙이 되도록 자세를 조정한 후 엑스선관과 척주팬톰 자세를 각각 수직으로 촬영하면 척주 측방향 촬영에서 두 개의 겹쳐진 영상을 얻을 수 있었고 주관적 평가에서도 높은 점수를 얻었다. 또한 허리뼈 탈구 골절된 허리뼈 측방향 촬영은 이마면을 IR면 중심에 일치시키고 네번째 허리뼈가 중앙이 되도록 자세를 조정하여 엑스선관 각도를 수직되게 하고 척주 팬톰을 네번째 허리뼈를 수직하여 촬영 하게 되면 척주 측방향 촬영에서 두개의 철심이 겹치는 영상을 얻을 수 있었고 주관적 평가에서도 높은 점수를 얻었다.

Merchant 검사 시 슬개대퇴관절 겹침 최소화를 위한 중심 X선 입사각에 대한 평가 (The Assessment of Tube Incidence Angle for Minimizing the Patellofemoral Joint Overlap Distance in Merchant View)

  • 고예원;주영철;김민석;고유림
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권3호
    • /
    • pp.161-167
    • /
    • 2020
  • This study aimed to found out the effect of patellofemoral overlap distance by changing femur thickness and center X-ray angles in Merchant method images. Based on the femur thickness, it suggested tube angle minimizes overlap. It was conducted by Merchant method, a knee tangential view, and the image was obtained by changing the thigh thickness from 14 to 20 cm and the center ray angle from 60°, 57°, 55°. The images were measured by five researchers using a method of measuring the overlap, which was designed by them. The results showed at 60°, 57°, 55° angle, the patellofemoral overlap distance resulted in 0.47±0.66 to 20.89±0.65 cm, 2.26±0.28 to 15.73±0.62 cm, 1.39 ± 0.83 to 12.49 ± 0.37 cm. However, for 57° and 55°, no overlap in thickness under 14.5 and 14 to 15.5 didn't appear. it showed high correlation between femur thickness and overlap. The difference in the mean value of overlap in each group showed a statistically significant difference (p<0.01), all were classified as independent groups in the post-hoc test. In all images, the patellofemoral overlap distance increased as the thickness increased, and at the average thickness of Korean men and women, overlap decreased when reducing center ray. When conducting Merchant tests on Koreans, it was suggested it would be useful to use 57° angle because it minimize the effects of overlap and intrusions of tibia.

금속제트 거동 분석에서의 FTOD 오차 보정에 관한 연구 (A Study on the Correction of Error Induced by FTOD for Investigation of a Metal Jet Behavior)

  • 주재현;이헌주;김시우
    • 한국군사과학기술학회지
    • /
    • 제17권5호
    • /
    • pp.577-584
    • /
    • 2014
  • In this study, the behavior of a shaped charge projectile's metal jet was analyzed using flash radiography. The projectile was installed horizontally to observe the behavior of jet for enough time. While the X-ray tube heads are fixed at one point, the behavior range of the jet is wide in this experimental set up, therefore the angle between the X-ray tube heads and the jet tip is changed continuously as jet moves forward. Jet particle's locations calculated from the X-ray films become different from their real positions under this situation because of the film to object distance(FTOD) and correction for error by FTOD is required. In this study, a method was devised to correct the error by FTOD and this was applied for the investigation of jet behavior of a 70 mm caliber's shaped charge.

양극의 경사각 효과에 따른 조사야 X-선 강도 분포 (Distribution of X-ray Strength in Exposure Field Caused by Heel Effect)

  • 장근조;김남훈;이준행;이상복
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.223-229
    • /
    • 2011
  • X선은 X선관 내 음극측 전자(electron)를 빠른 속도로 가속시킨 다음 진행하는 전자의 흐름을 저지극(target)에서 차단시킬 때 에너지의 변환을 일으켜 발생한다. 가속된 고속의 전자가 저지면에 충돌하는 실제면적을 실초점(actual focal spot)이라 하고, 실초점의 크기를 X선이 나오는 방향인 중심선(central ray)측에서 관측할 경우 축소되어 작게 보이는데 이때의 초점을 실효초점(effective focal spot)이라고 한다. X선관 방사각에 따라 음극 측의 강도가 양극 측 보다 높게 나타나 X선 강도가 균등하지 않다. 이러한 효과를 경사각 효과(heel effect)라고 하며, 경사각 효과로 인하여 환자가 받는 피폭의 정도는 양극의 각도, 즉 실효초점의 크기에 따라 달라지게 된다. 본 논문에서는 실효초점의 크기와 그에 따른 환자 피폭선량의 상관관계를 알아보고 실효초점의 크기에 따른 균질선량 분포를 위한 효과적인 조사야를 제시하고자 한다. 결론적으로 초점크기에 따라서 평균적으로 -8cm ~ 0cm 범위에서 효과적인 조사야 범위를 찾을 수 있었고, 평균 선량률은 0.019 R/min이 나왔다. 이 범위를 이용하면 환자에게는 적은 피폭선량으로 균등한 흑화도 및 해상력을 가진 영상을 얻을 수 있을 것이다.

현장 적용이 가능한 X선 CT 시스템 개발 I - X선 촬영법을 이용한 목재의 밀도 측정 - (Development of Portable X-ray CT System I - Evaluation of Wood Density using X-ray Radiography -)

  • 김광모;이상준;이전제
    • Journal of the Korean Wood Science and Technology
    • /
    • 제34권1호
    • /
    • pp.15-22
    • /
    • 2006
  • 국내에서 문화재로 지정되어 관리되고 있는 많은 목조 고건축물들의 효과적인 보존 및 관리를 위해서는 목재의 내부 상태를 정확하게 평가할 수 있든 비파괴 검사법이 요구된다. 따라서 본 연구에서는 현장에서 적용 가능한 X선 CT 시스템을 개발하기 위한 연구의 일환으로, 먼저 휴대형 soft-X선 촬영 장치를 사용한 목재의 밀도측정 방법을 확립하고 그 적용 가능성을 확인하고자 하였다. 먼서 측정방법을 확립하기 위하여 X선 강도와 필름명도 사이의 상관관계를 분석하였으며, 또한 관전류와 관전압의 변화에 따른 X선 초기강도의 변화를 확인하여 정량화 하였다. 다음으로 목재의 밀도와 연륜각, 두께가 질량감쇠계수에 미치는 영향을 확인하고, 목재의 침량감쇠계수를 결정하여 Beer의 법칙에 적용함으로써 X선 측정결과로부터 목재의 밀도를 계산할 수 있는 식을 제시하였다. 마지막으로 X선 촬영법을 통해 측정한 밀도를 기존의 치수법에 의한 측정결과와 비교함으로써 앞에서 결정된 밀도측정 방법의 작용 가능성을 확인할 수 있었다. 이상의 결과는 앞으로 개발하고자 하는 X선 CT 시스템에서 입력값으로 요구되는 밀도를 측정하는 방법을 확립하는데 있어서 효과적으로 활용될 수 있을 것으로 기대된다.

무릎뼈의 변형된 접선방향 검사 시 최적의 입사각에 관한 연구 (A Study on the Optimal Angle as Modified Tangential Projection of Knee Bones)

  • 오왕균;김상현
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.919-926
    • /
    • 2021
  • 본 연구는 무릎뼈의 변형된 접선 방향 검사 시 최적의 입사각에 대해 알아보고자 하였다. 실험은 Kyoto Kagaku사의 PBU-50 phantom을 이용하여 바로 누운 자세에서 넙다리뼈-정강뼈 각도(Femur-tibia angle, F-T angle)를 95°, 105°, 115°, 125°, 135°, 145°로 각각에서 X선 중심선과 정강뼈가 이루는 각도가 5~20° 되도록 5°씩 변경하여(62.5°, 67.5°, 72.5°, 77.5°, 82.5°, 87°, 87.5°) 무릎뼈 접선 방향 영상을 획득하였다. 영상분석을 위해 Image J를 이용하여 Congruence angle, Lateral patellofemoral angle, Patellofemoral index, 대조도 잡음비(Contrast to noise ratio, CNR)를 측정하였다. 통계 분석은 SPSS 22를 이용하여 일원배치분산분석과 대응표본 t-검정으로 Merchant method와 비교하였다. 연구 결과 Congruence angle의 경우 무릎 각도-X선 중심선의 입사각도가 105°-72.5°(20° 접선조사), 115°-72.5°, 77.5°(15, 20° 접선조사), 125°-82.5°(20° 접선조사), Lateral patellofemoral angle은 115°-72.5°, 77.5°(15, 20° 접선조사), 125°-72.5°(10° 접선조사), Patellofemoral index는 115°-72.5°(15° 접선조사), 125°-72.5°(10° 접선조사)에서 Merchant method와 유의한 차이가 없었다(p>.05). CNR의 경우 105°-67.5°, 72.5°(15, 20° 접선조사), 115°-67.5°, 72.5°, 77.5°(10, 15, 20°접선 조사)일 때 Merchant method와 차이가 없는 것으로 나타났다(p>.05). 본 연구의 결과를 통해 무릎뼈의 변형된 접선방향 검사 시 무릎 각도와 X선관의 입사각도를 각각 115°-72.5°(15° 접선 조사)로 설정함으로써 진단적 가치가 높은 영상을 획득할 수 있음을 확인하였다.