• Title/Summary/Keyword: x-ray film

Search Result 2,293, Processing Time 0.035 seconds

Photocurrent study on the splitting of the valence band and growth of $CdGa_2Se_4$ single crystal thin film by hot wall epitaxy (Hot Wall epitaxy(HWE)법에 의한 $CdGa_2Se_4$ 단결정 박막의 성장과 가전자대 갈라짐에 대한 광전류 연구)

  • Park, Chang-Sun;Hong, Kwang-Joon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.17 no.5
    • /
    • pp.179-186
    • /
    • 2007
  • Single crystal $CdGa_2Se_4$ layers were grown on a thoroughly etched semi-insulating GaAs(100) substrate at $420^{\circ}C$ with the hot wall epitaxy(HWE) system by evaporating the polycrystal source of $CdGa_2Se_4$ at $630^{\circ}C$. The crystalline structure of the single crystal thin films was investigated by the photoluminescence and double crystal X-ray diffraction(DCXD). The carrier density and mobility of single crystal $CdGa_2Se_4$ thin films measured with Hall effect by van der Pauw method are $8.27{\times}10^{17}cm^{-3},\;345cm^2/V{\cdot}s$ at 293 K, respectively. The photocurrent and the absorption spectra of $CdGa_2Se_4/SI$(Semi-Insulated) GaAs(100) are measured ranging from 293 K to 10 K. The temperature dependence of the energy band gap of the $CdGa_2Se_4$ obtained from the absorption spectra was well described by the Varshni's relation $E_g(T)=2.6400eV-(7.721{\times}10^{-4}eV/K)T^2/(T+399K)$. Using the photocurrent spectra and the Hopfield quasicubic model, the crystal field energy(${\Delta}cr$) and the spin-orbit splitting energy(${\Delta}so$) far the valence band of the $CdGa_2Se_4$ have been estimated to be 106.5 meV and 418.9 meV at 10 K, respectively. The three photocurrent peaks observed at 10 K are ascribed to the $A_{1^-},\;B_{1^-},\;and\;C_{11}-exciton$ peaks.

Magnetic Properties of RF Diode Sputtered FeN Multilayer Films (RF Diode 스퍼터 방법으로 증착된 FeN 다층 박막의 자기적 특성)

  • 최연봉;박세익;조순철
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.1
    • /
    • pp.42-47
    • /
    • 1995
  • FeN thin films for inductive recording heads were sputter deposited using RF diode sputtering mehtod from a pure iron target onto 7059 glass substrates, and their magnetic properties were measured. The magnetic properties were greatly affected by film thickness, gas pressure, sputter power and flow ratio of $N_{2}$ to Ar. Single layer FeN films with their thickness varied from $1,000\;{\AA}$ to $6,000\;{\AA}$ were doposited. 800 W sputter power, 3 mT gas pressure, $N_{2}$ to Ar flow ratio of 6.6 : 100 were the sputtering conditions. Up to 7 layers of FeN films having total thickness of $6,000\;{\AA}$ were deposited using $SiO_{2}$ of $30\;{\AA}$ thickness as intermediate layers and their coercivity and saturation magnetization were measured. The sputtering conditions were the same as those in the single layer films. Easy axis coercivity of the single layer FeN films gradually decreased as their thickness was increased, but for the films with their thicknesses above $3,000\;{\AA}$, the coercivity changed very little. As the number of the FeN layers were increased, the coercivity decreased We estimated the grain size of FeN films from the FWHM (Full Width at Half Maximum) of X-ray diffraction peaks. The grain size steadily decreased from about $200\;{\AA}$ to $120\;{\AA}$ as the number of layers were increased. Minimum hard axis coercivity of 0.4 Oe was obtained when the number of layers was four. Maximum relative permeability was 2,900 when the number of layers was three. The cut off frequeocy of the multilayer films were above 100 MHz.

  • PDF

Swelling Behavior and Hydration Number of Langmuir-Blodgett Films of Metal-Palmitate Deposited on a Piezoelectric Quartz Crystal Plate (압전수정결정판 위에 적층된 금속-Palmitate Langmuir-Blodgett 막의 팽창거동 및 수화수)

  • Jong-Jae Chung;Byung-Il Seo;Hai-Won Lee
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.3
    • /
    • pp.302-308
    • /
    • 1993
  • Monolayers of calcium palmitate were deposited on a piezoelectric quartz crystal plate by the Langmuir-Blodgett(LB) technique, and it was found from frequency changes of the quartz crystal deposited LB films. The usual carbonyl absorbance at 1704 cm$^{-1}C$ was replaced by the split band in the 1540~1590 cm$^{-1}C$. The two absorptions at 1580 cm$^{-1}C$ and 1540 cm$^{-1}C$ were assigned to the antisymmetric stretching vibration of the calcium carboxylate group and the hydrated species due to the lowering carbonyl stretching frequency by hydrogen bonding$^1$ respectively. Besides, it was demonstrated by X-ray diffraction analysis. The swelling behaviour of LB films in water phase at 23$^{\circ}C$ was observed from the frequency change of the LB films deposited quartz crystal with time. Calcium palmitate LB films has been found to swell substantially in water without flaking, whereas hexadecanol LB films hardly swelled in water. Amount of swelling of calcium palmitate LB films was equivalent to 47 wt.${\%}$ of the dry LB films, which means that ca. 7 water molecules were incorporated per calcium palmitate amphiphile. Chemical structure of calcium palmitate LB film was estimated as [CH$_3$(CH$_2$)$_{14}$COO]$_2$Ca${\cdot}$XH$_2$O, and the hydration number was 1.

  • PDF

Effect of Oxyfluorination on Electroless Ni Deposition of Carbon Nanotubes (CNTs) and Their EMI Shielding Properties (탄소나노튜브의 무전해 니켈도금 및 전자파 차폐 특성에 미치는 함산소불소화의 영향)

  • Choi, Ye Ji;Lee, Kyeong Min;Yun, Kug Jin;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.30 no.2
    • /
    • pp.212-218
    • /
    • 2019
  • To investigate the effect of the oxyfluorination of carbon nanotubes (OF-CNTs) on electroless Ni deposition and electromagnetic interference shielding efficiency (EMI SE), CNTs were treated with a mixture of oxygen and fluorine gases and sequentially deposited with nickel. These samples were then manufactured into thin films on a polyimide film to evaluate their EMI SE. The surface chemical property of OF-CNTs was investigated by X-ray photoelectron spectroscopy. From the results of thermogravimetric and scanning electron microscopic analyses, it was found that both the amount of deposited Ni and the surface morphology changed depending on oxyfluorination. Moreover, the Ni-deposited CNTs pretreated with $O_2:F_2=1:9vol%$ exhibited the maximum EMI SE as approximately 19.4 dB at 1 GHz. These results were attributed to the formation of oxygen and fluorine functional groups on the surface of CNTs due to the oxyfluorination, and the functional groups enabled to deposit a suitable amount of Ni and improve the dispersion in the deposited solution.

CLINICAL STUDY ON THE ANOMALLES OF NUMBER AND MORPHOLOGY IN CLEFT LIP AND PALATE PATIENTS' TEETH (순구개열환자의 치아 수와 형태 이상에 관한 연구)

  • Baek, Seung-Hak;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.51-61
    • /
    • 2001
  • Cleft lip and/or palate (CLP) is one of the most common congenital craniofacial anomalies and occurs more frequently in Asian people. Dental abnormalities in number, size, shape, and eruption of teeth are frequently associated with CLP. The purposes of this study were to investigate the effects of CLP on number, size, shape and eruption of teeth and to provide basic clinical data for diagnosis and treatment of the CLP patients. With the orthodontic and cleft charts, diagnostic models, orthopantomograms and intraoral x-ray films from 241 CLP patients who visited Dept. of Orthodontics, Seoul National University Dental Hospital, we evaluated the frequency of congenital missing teeth, supernumerary teeth, Impacted teeth, and microdontia. The results were as fellows ; 1. Frequency of congenital missing was relatively high up to $56.8\%$. Congenital missing occurred frequently in the maxillary lateral incisor and the maxillary second premolar. Among the CLP types, frequencies of congenital missing in cleft lip and Palate group and cleft lip and alveolus group were higher than those of cleft lip group and cleft palate group. And bilateral cleft showed higher frequencies than unilateral ones. 2. Supernumerary tooth was shown in $11.2\%$ of CLP patients. It occurred frequently in the area between the maxillary lateral Incisors and the maxillary canine. Among the CLP types, cleft lip group showed relatively most highest frequency. 3. Impaction was shown in $18.3\%$ of CLP patients. It occurred most frequently In the maxillary lateral incisor and the maxillary canine than other teeth. Among the CLP types, cleft lip group and cleft lip and palate group showed most highest frequencies. 4. Microdontia was shown in $15.8\%$ of CLP patients. It occurred the most frequently In the maxillary lateral incisors and maxillary canines. Among the CLP types, cleft lip and alveolus group and cleft lip and palate group showed relatively higher frequencies. There was no microdontia in cleft palate group.

  • PDF

Enhanced Device Performance of IZO-based oxide-TFTs with Co-sputtered $HfO_2-Al_2O_3$ Gate Dielectrics (Co-sputtered $HfO_2-Al_2O_3$을 게이트 절연막으로 적용한 IZO 기반 Oxide-TFT 소자의 성능 향상)

  • Son, Hee-Geon;Yang, Jung-Il;Cho, Dong-Kyu;Woo, Sang-Hyun;Lee, Dong-Hee;Yi, Moon-Suk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.6
    • /
    • pp.1-6
    • /
    • 2011
  • A transparent oxide thin film transistors (Transparent Oxide-TFT) have been fabricated by RF magnetron sputtering at room temperature using amorphous indium zinc oxide (a-IZO) as both of active channel and source/drain, gate electrodes and co-sputtered $HfO_2-Al_2O_3$ (HfAIO) as gate dielectric. In spite of its high dielectric constant > 20), $HfO_2$ has some drawbacks including high leakage current and rough surface morphologies originated from small energy band gap (5.31eV) and microcrystalline structure. In this work, the incorporation of $Al_2O_3$ into $HfO_2$ was obtained by co-sputtering of $HfO_2$ and $Al_2O_3$ without any intentional substrate heating and its structural and electrical properties were investigated by x-ray diffraction (XRD), atomic force microscopy (AFM) and spectroscopic ellipsometer (SE) analyses. The XRD studies confirmed that the microcrystalline structures of $HfO_2$ were transformed to amorphous structures of HfAIO. By AFM analysis, HfAIO films (0.490nm) were considerably smoother than $HfO_2$ films (2.979nm) due to their amorphous structure. The energy band gap ($E_g$) deduced by spectroscopic ellipsometer was increased from 5.17eV ($HfO_2$) to 5.42eV (HfAIO). The electrical performances of TFTs which are made of well-controlled active/electrode IZO materials and co-sputtered HfAIO dielectric material, exhibited a field effect mobility of more than $10cm^2/V{\cdot}s$, a threshold voltage of ~2 V, an $I_{on/off}$ ratio of > $10^5$, and a max on-current of > 2 mA.

Growth and optical conductivity properties for BaIn2S4 single crystal thin film by hot wall epitaxy (Hot Wall Epitaxy(HWE)법에 의한 BaIn2S4 단결정 박막 성장과 광전도 특성)

  • Jeong, Kyunga;Hong, Kwangjoon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.5
    • /
    • pp.173-181
    • /
    • 2015
  • A stoichiometric mixture of evaporating materials for $BaIn_2S_4$ single crystal thin films was prepared from horizontal electric furnace. To obtain the single crystal thin films, $BaIn_2S_4$ mixed crystal was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the Hot Wall Epitaxy (HWE) system. The source and substrate temperatures were $620^{\circ}C$ and $420^{\circ}C$, respectively. The crystalline structure of the single crystal thin films was investigated by double crystal X-ray diffraction (DCXD). The carrier density and mobility of $BaIn_2S_4$ single crystal thin films measured from Hall effect by van der Pauw method are $6.13{\times}10^{17}cm^{-3}$ and $222cm^2/v{\cdot}s$ at 293 K, respectively. The temperature dependence of the energy band gap of the $BaIn_2S_4$ obtained from the absorption spectra was well described by the Varshni's relation, $E_g(T)=3.0581eV-(3.9511{\times}10^{-3}eV/K)T^2/(T+536K)$. The crystal field and the spin-orbit splitting energies for the valence band of the $BaIn_2S_4$ have been estimated to be 182.7 meV and 42.6 meV, respectively, by means of the photocurrent spectra and the Hopfield quasicubic model. These results indicate that the splitting of the ${\Delta}so$ definitely exists in the ${\Gamma}_5$ states of the valence band of the $BaIn_2S_4/GaAs$ epilayer. The three photocurrent peaks observed at 10 K are ascribed to the $A_1$-, $B_1$-exciton for n = 1 and $C_{24}$-exciton peaks for n = 24.

Characteristics of 15 MV Photon Beam from a Varian Clinac 1800 Dual Energy Linear Accelerator (CLINAC 1800 선형가속기의 15 MV X-선의 특성)

  • Kim, Kye-Jun;Lee, Jong-Young;Park, Kyung-Ran
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.131-141
    • /
    • 1991
  • A comprehensive set of dosimetric measurements has been made on the Varian Clinac 1800 15 MV photon beam. Beam quality, percentage depth dose, dose in the build up region, output, symmetry and flatness, transmission through iead (Cerrobend), tray attenuation, isodose curves for the open and wedged fields were measured using 3 dimensional water phantom dosimetry system (including film densitometer system) and polystyrene phantoms. These dosimetric measurements sufficiently characterized the beam to permit clinical use. The depth dose characteristics of photon beam is $d_{max}$ of 3.0 cm and percentage depth dose of $76.8\%$ at 10 cm,100 cm source-surface distance, field size of $10\times10\;cm^2$ for 15 MV X-ray beam. The Output factors ranged 0.927 for $4\times4\;cm^2$ field to 1,087 for $35\times35\;cm^2$ field. The build-up level of maximum dose was at 3.0 cm and surface dose was approximately $15.5\%$ for a field size $10\times10\;cm^2$ The stability of output is $within\pm1\%$ and flatness and symmetry are $within\pm3\%$. The half value thickness (HVL) of lead is 13 mm, which corresponds to an attenuation coefficient of $0.053\;mm^{-1}$. These figures compare facorably with the manufacturesr`s specifications.

  • PDF

The Role of Air-Vacuum Cushion Device in Patients with Rectal Cancer in Radiation Therapy (직장암 환자에서 방사선치료시 Air-vacuum Cushion의 유용성)

  • Kim Ki-Hwan;Cho Moon-June;Kang No-Hyun;Kim Dong-Wuk;Kim Jun-Sang;Jang Ji-Young;Kim Jae-Sung
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.287-292
    • /
    • 2001
  • Prupose : We analyzed setup errors induced by using air-vacuum cushion as immobilization device in patients with rectal cancer. Materials and methods : We had treated the twenty patients with rectal cancer by 6 MV, 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at prone position. They were separated to two groups, control group, 10 patients using styrofoam, and test group, 10 patients using styrofoam and air-vacuum cushion. We measured errors of posterior field for x, y axis and lateral field for z, y axis with simulation film and EPID image using a matching technique. Results : In control group, the mean displacement values of pelvic bone landmark for x axis and y axis were 0.02 mm. 0.78 mm, respectively and the standard deviations of systematic error were 2.13 mm, 2.40 mm, respectively and the standard deviation of random error were 1.46 mm. 1.51 mm, respectively. In test group, the mean displacement values of x axis and y axis were -0.33 mm. 0.81 mm, respectively and the standard deviations of systematic error were 1.71 mm, 3.08 mm, respectively and the standard deviations of random errors were 1.40 mm. 1.88 mm, respectively. The mean displacement values of z axis and y axis were 2.98 mm. 0.74 mm, respectively and the standard deviations of systematic error were 4.75 mm, 2.65 mm, respectively and standard deviations of random error were 2.69 mm. 1.86 mm, respectively. The statistical difference of field size by using air vacuum cushion between two groups in posterior direction and lateral direction was not shown. Conclusion : We think that use of air-vacuum cushion may not be an advantage for improving setup accuracy in rectal cancer patients.

  • PDF

Clinical Study of Pulmonary Tuberculosis for Admitted Patients at National Masan Tuberculosis Hospital (국립마산결핵병원에 입원한 환자에 대한 폐결핵의 임상적 동태에 관한 연구)

  • Park, Seung-Kyu;Choi, In-Hwan;Kim, Chul-Min;Kim, Cheon-Tae;Song, Sun-Dae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.241-250
    • /
    • 1997
  • Objective : Although the prevalence of pulmonary tuberculosis has decreased progressively after the national control program for tuberculosis began, nowadays the number of MDRTB is increasing seriously. MDRTB tends to be poor responsive to current antituberculosis regimens. It is mainly due to poor compliance, high rate of side reaction of secondary drugs, and limitation in number of available drugs. The purpose of present study is to evaluate the clinical features of pulmonary tuberculosis patients admitted in one national tuberculosis hospital and to expose the problems pertaining to current remedies, to increase the treatment efficacy for pulmonary tuberculosis including MDRTB in the end. Method : Retrospective analysis of 336 pulmonary tuberculosis patients admitted in National Masan Tuberculosis Hospital was done. Contents of analysis were patients profile, the first diagnosed time and medical institutes, family history, residence, previous treatment history, chief complaints at the time of admission, lesion site on chest X -ray film, combined deseases, side reaction to antibuberculosis drugs, used drugs before admission and the results of drug sensitivity test. Results : The ratio between male and female was 4 : 1. Age showed relatively even distribution from 3rd to 6 th decades. 64.6% of the patients was diagnosed at public health center. Weight loss was the most common complaint at admission. Bilateral lesions on chest X-ray films were 59.8%. 130patients had combined desease, of which DM was the most common(37.7%). 95patients had family history, of which parents were the most common(41.7%). According to the time of first diagnosis, 31 patients were diagnosed before 1980, and after then the number of patients was increased by degrees. Residence overwhelmed in pusan and gyung-nam province. 258 patients got previous treatment history, of which 112 patients(43.4%) had more than 3 times and only 133 patients(51.6%)got regular medication. 97 patients used more than other 3 drugs in addition to INH, EMB, RFP and PZA before admission. 154 patients were informed with the results of drug sensitivity test. of which 77 patients had resistance to more than 5 drugs. Gastrointestinal problem was the most common in side reaction to drugs. Conclusion : In the case of weight loss of unknown cause, tuberculosis should be suspected. In first treatment, sufficient and satisfactory explanation for tuberculosis is necessary and treatment period should not be stict to 6 month-short term therapy. In retreatment, new drugs should not be added to used drugs even though drug sensitivity results show sensitivity to some of them. Proper time for surgical intervention should not be delayed.

  • PDF