• Title/Summary/Keyword: worst-case analysis

Search Result 294, Processing Time 0.026 seconds

Productivity of the Health Center and Efficient Inputs & Outputs in Kyungnam Province (보건소 보건사업의 효율성 평가와 정책적 의의 - DEA를 이용한 경상남도 사례분석 -)

  • 김진현;유왕근
    • Health Policy and Management
    • /
    • v.9 no.4
    • /
    • pp.87-119
    • /
    • 1999
  • The main purpose of this research is to measure and analyze how productive the health centers are and how much inputs(or outputs) in the inefficient health centers should be decreased(or increased) for efficiency. The evaluation of the performance of health centers gives a strong incentive to improve resource allocation in regional health planning. It has been, however, implemented very rarely until now. In this regard, this paper measures the performance of the health centers with a single indicator for multiple-outputs in terms of productivity(technical efficiency), based on Data Envelopment method. The 20 Kyungnam health centers which provide clinic services and specific primary health care services were analyzed. The results show that 50.0% of 20 health centers were productive with respective to overall technical efficiency, 65.0% were productive for pure technical efficiency, and 50.0% for scale efficiency. The inefficient group includes Geoje, Mahsan, Miryang, Sahchun, Tongyoung, Gosung, Nahmhae, Euryang, Hahmahn, Hahbchun health centers. The worst case was identified as Tongyoung health center which represented a 47.5% efficiency, compared with productive health centers. The empirical results for input-output analysis indicates that the low-productive health centers have excessive manpower in administration department, producing low outputs in clinical services and vaccination program. These findings imply that a systemic evaluation of the performance of the Korean health centers and the subsequent structural reform are strongly required.

  • PDF

Reliability Estimation of Door Hinge for Home Appliances (가전제품용 경첩의 신뢰성 추정)

  • 문지섭;김진우;이재국;이희진;신재철;김명수
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2004.07a
    • /
    • pp.303-311
    • /
    • 2004
  • This paper presents the reliability estimation of door hinge for home appliances, which consists of bushing and shaft. The predominant failure mechanism of bushing made of polyoxymethylene(POM) is brittle fracture due to decrease of strength caused by voids existing, and that of shaft made of acrylonitrile-butadiene-styrene(ABS) is creep due to plastic deformation caused by excessive temperature and lowering of glass transition temperature by absorbed moisture. Since the brittle fracture of bushing is overstress failure mechanism, the load-strength interference model is used to estimate the failure rate of it along with failure analysis. By the way, the creep of shaft is wearout failure mechanism, and an accelerated life test is then planned and implemented to estimate its lifetime. Through the technical review about failure mechanism, temperature and humidity are selected as accelerating variables. Assuming Weibull lifetime distribution and Eyring model, the life-stress relationship and acceleration factor, B$_{10}$ life and its lower bound with 90% confidence at worst case use condition are estimated by analyzing the accelerated life test data.a.

  • PDF

A Case Study on the Evaluation of Residential Performance for Deteriorated Multi-family Housing (노후공동주택의 거주성능 평가에 관한 사례 연구)

  • Hyun Taek-Soo;Lee Byung-Tae
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.77-85
    • /
    • 2006
  • This study aims to propose the comprehensive evaluation of performance multi-family housing. Most of the existing studies for the reproduction have evaluated by the safety of structure. Therefore those pass over the functional factors which is important for the evaluation of residential qualities. This study represents that the reproduction renovation should not be secured the safety of structure but established the quality of lift. And questionnaire asking expert's opinion also supplemented. As a result, the item for examination and the weight for evaluation are suggested in functional deterioration. The results of this study are summarized as follows: 1. Existent redevelopment criteria are not appropriate to decide the environmental comfort, the vital function of housing and the residential management finance. 2. The future criteria have to evaluate the existing environmental comfort, be reconstructed to put first general deterioration. 3. Evaluation elements was extracted throughout the document research, evaluation elements analysis system was separated in residential area, suburb of dwellings, community, and housing complexity environmental assesment, 4. Each category of influence ratio was extracted to assess total deterioration throughout the expert question survey. 5. Each category analysed (1) $0{\sim}30%$: function is good (unnecessary to improve) (2) $31{\sim}40%$: average (necessary of partial improvement) (3) $41{\sim}59%$: bad (necessary of total improvement) (4) $60{\sim}100%$: the worst (unable to improve throughout the repair)

Analysis of Joule-heat Characteristics according to the DC-link Capacitor Film Geometrics (DC-link Capacitor필름 형상에 따른 Joule-heat특성 분석)

  • Jeon, Yong Won;Kim, Young Shin;Jeon, Euy Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.1
    • /
    • pp.42-48
    • /
    • 2020
  • As global warming accelerates, eco-friendly electric cars are being developed to reduce carbon dioxide emissions, and power conversion inverters are used to drive motors. Among inverter components, DC-link capacitor is heated by high current usage, which causes problems such as performance and life-saving of inverter. Although metal cases with good thermal performance have been used to solve this problem, it is difficult to apply them in practice due to insulation problems with other parts. In this paper, the Heat-Generation influence factor of DC-link capacitor is analyzed. Variables on heat-generation are set at 3 levels for film width, inductance, and film thickness. Box-Behnken to 13 tests using the design and minimal deviations, e.g. through the experiment three times by each level. The surface of the film k type by attaching the sensor current is measured temperature. Capacitance was set to a minimum level of 200 ㎌ and had a frequency of 16 kHz with Worst case, ambient temperature of 85℃ and a ripple current of 50 Ams was applied. The temperature at the measurement point was collected in the data logger after sampling at 1 minute intervals for 2 hours after saturation with the ambient temperature. This experiment confirmed that setup factors are correlated with heat-generation.

Evaluation of Degradation and Safety of Small Agricultural Reservoir (소규모 농업용 저수지의 노후도 및 안전도 평가 -고삼 저수지에 대한 사례 연구-)

  • 장병옥;박영곤;우철웅
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.1
    • /
    • pp.49-56
    • /
    • 1998
  • Ths study was peformed to evaluate the degree of degradation and safety of a small agricultural reservoir, Kosam Reservoir, in Kyungki Province. Evaluation was done by the program developed by the authors. Results of the study are as follows: 1) Although many burrows were found in downstream side of embankment and cracks were found in wall joining spillway, it appeared that degree of degradation of embankment was in good conditions. 2) Compressive strengths of concrete of crest, side channel, chute floor of spillway were in poor condition. But it appeared that overall degree of degradation of structures was in medium condition based on the criteria of the evaluation system 3) From the analysis of slope stability, safety factor of downstream slope was over 3.3 for the worst condition, such as flood and high water level and that of upstream slope was also over 3.6 for rapid drawdown. In case of earthquake, safety factors were over 2.5 for all conditions. Therefore embankment slopes of Kosam Reservoir were very stable for normal and earthquake condition. 4) As upon assumed failure of embankment of Kosam Reservoir, degree of damage was estimated to be very serious because of many loss of life and properties in the downstream area. 5) Overall grade of safety of Kosam Reservoir was in good condition. Therefore safety was considered to be "No problems" at the present time but further degradation may be proceeded partly and continuously as time goes by.e goes by.

  • PDF

Application of the Optical Hough Transform for the Detection of a General Ellipse (일반 타원의 검출을 위한 광학적 Hough변환의 적용)

  • Park, Sang-Gug;Kim, Sung-Yong;Kim, Soo-Joong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.8
    • /
    • pp.67-75
    • /
    • 2000
  • In this paper, we proposed a new method to find dive parameters of an ellipse from the optical Hough transform (HT) results. The method employs the HT for detection of a straight line and the one-dimensional analysis of the resultant parameter domain. Using this algorithm, we simulated about the ellipses with different positions, and obtained the information of the ellipse with 94% accuracy in the worst case. To compare the simulation results with the experimental ones, we performed optical experiments using a HT Computer Generated Hologram (CGH) filter. Through the experiments, we showed that our results were very similar to the simulation results.

  • PDF

Performance Analysis of Timer Assignment and Utilization of the IEEE 802.4 Token Bus for Real Time Processing (실시간 처리를 위한 IEEE 802.4 토큰버스 네트워크의 타이어 할당과 유용도 처리 성능 해석)

  • Kim, Jeong-Ho;Lee, Min-Nam;Lee, Sang-Beom
    • The Transactions of the Korea Information Processing Society
    • /
    • v.1 no.3
    • /
    • pp.357-366
    • /
    • 1994
  • The IEEE 802.4 token bus has been widely accepted as the standard for factory local area networks. The priority option of the 802.4 standard supports multiple classes of traffic by using a set of timers to control information exchange. The performance of the 802.4 priority mechanism in industrial real time control is examined. A timer assignment technique is presented for such applications. The timers are set to satisfy the worst case access delay requirements of real time control applications. Other applications that are not time constrainted can be supported simultaneously. In fact under certain conditions, such applications can also be guaranteed a minimum bandwidth allocation. Simulation results are used to evaluate the timer assignment and utililization.

  • PDF

An Efficient Tag Identification Algorithm using Bit Pattern Prediction Method (비트 패턴 예측 기법을 이용한 효율적인 태그 인식 알고리즘)

  • Kim, Young-Back;Kim, Sung-Soo;Chung, Kyung-Ho;Kwon, Kee-Koo;Ahn, Kwang-Seon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.5
    • /
    • pp.285-293
    • /
    • 2013
  • The procedure of the arbitration which is the tag collision is essential because the multiple tags response simultaneously in the same frequency to the request of the Reader. This procedure is known as Anti-collision and it is a key technology in the RFID system. In this paper, we propose the Bit Pattern Prediction Algorithm(BPPA) for the efficient identification of the multiple tags. The BPPA is based on the tree algorithm using the time slot and identify the tag quickly and efficiently using accurate bit pattern prediction method. Through mathematical performance analysis, We proved that the BPPA is an O(n) algorithm by analyzing the worst-case time complexity and the BPPA's performance is improved compared to existing algorithms. Through MATLAB simulation experiments, we verified that the BPPA require the average 1.2 times query per one tag identification and the BPPA ensure stable performance regardless of the number of the tags.

A Conservative Safety Study on Low-Level Radioactive Waste Repository Using Radionuclide Release Source Term Model (선원항 모델을 사용한 저준위 방사성폐기물 처분장의 보수적인 안전성고찰)

  • Kim, Chang-Lak;Lee, Myung-Chan;Cho, Chan-Hee
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.63-70
    • /
    • 1993
  • A simplified safety assessment is carried out on rock-cavern type disposal of LLW using the analytical repository source term (REPS) model. For reliable prediction of the leach rates for various radionuclides, degradation of concrete structures, corrosion rate of waste container, degree of corrosion on the container surface, and the characteristics of radionuclides are considered in the REPS model. The results of preliminary assessment show that Cs-137, Ni-63, and Sr-90 are dominant. For the parametric uncertainty and sensitivity analysis, Latin hypercube sampling technique and rank correlation technique are applied. The results of the potential public health impacts show that radiological dose to intruder in the worst case scenario will be negligible and that more attention should be given to near-field performance.

  • PDF

Performance Analysis of Cyclostationary Interference Suppression for Multiuser Wired Communication Systems

  • Im, Gi-Hong;Won, Hui-Chul
    • Journal of Communications and Networks
    • /
    • v.6 no.2
    • /
    • pp.93-105
    • /
    • 2004
  • This paper discusses cyclostationary interference suppression for multiuser wired communication systems. Crosstalk interference from digital signals in multipair cables has been shown to be cyclostationary. Many crosstalk equalization or suppression techniques have been proposed which make implicit use of the cyclostationarity of the crosstalk interferer. In this paper, the convergence and steady-state behaviors of a fractionally spaced equalizer (FSE) in the presence of multiple cyclostationary crosstalk interference are thoroughly analyzed by using the equalizer's eigenstructure. The eigenvalues with multiple cyclostationary interference depend upon the folded signal and interferer power spectra, the cross power spectrum between the signal and the interferer, and tile cross power spectrum between the interferers, which results in significantly different initial convergence and steady-state behaviors as compared to the stationary noise case. The performance of the equalizer varies depending on the relative clock phase of the symbol clocks used by the signal and multiple interferers. Measued characteristics as well as analytical model of NEXT/FEXT channel are used to compute the optimum and worst relative clock phases among the signal and multiple interferers.