• Title/Summary/Keyword: workers' health and safety

Search Result 1,430, Processing Time 0.033 seconds

Development of a monolithic apparatus for degasing aluminum continuous casting molten metal (알루미늄 연속주조 용탕의 탈 가스 일체화 장치 개발)

  • 이용중;김태원;김기대;류재엽;이형우
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.145-149
    • /
    • 2004
  • It is necessary for managing a perfect process for degasing aluminum molten metal according to the increase of a grade of aluminum and its alloy products. There are some methods that have been used to manage a degasing process in recent years, such as an injection method that uses aluminum molten metal powder and chemicals supplier and input method that supplies argon and nitrogen, or chlorine gas by using a gas blow-tube. However, these methods show some problems, and it shows that it is a difficult process to handle. pollution due to the producing a lot of toxic gases like chlorine and fluoride gas. irregular effects, and lowering work efficiency due to the excessive processing time. The problems that are the most fatal are the producing a lot of sludge due to the reaction of aluminum molten metal with chemicals. loss of metals, and decreasing the life of refractory materials. In order to solve these problems. this paper develops a technology that is related to aluminum continuous casting molten metal and monolithic degasing apparatus. A degasing apparatus developed in this study improved the exist ing methods and prevented environmental pollution wi th smokeless. odor less, and harmlessness by using a new method that applies argon and nitrogen gas in which the methods used in the West and Japan are eliminated. The developed method can significantly reduce product faults that are caused by the production of gas and oxidation because it uses a preprocessed molten metal with chemicals. In addition. the amount of the produced sludge can also be reduced by 60-80% maximum compared with the existing methods. Then. it makes it possible to minimize the loss of metals. Moreover. the molten metal processing and settling time is also shortened by comparing it with the existing methods that are applied by using chemicals. In addition, it does much to improve the workers' health, safety and environment because there is no pollution. The improvement of productivity and prevent ion effects of disaster from the results of the development can be summarized as follows. It will contribute to the process rationalization because it does not have any unnecessary processes that the molten metal will be moved to an agitator by using a ladle and returned to process for degasing like the existing process due to the monolithic configuration. There are no floating impurities due to the oxidation caused by the contact with the air as same as the existing process. In addition. it can protect the blending of precipitation impurities. Because it has a monolithic configuration. it can avoid the use of additional energy to compensate the temperature decreasing about 60t that is caused by the moving of molten metal. It is not necessary to invest an extra facilities in order to discharge the gas generated from a degasing process by using an agitator. The working environment can be improved by the hospitable air in the factory because the molten metal is almost not exposed in the interior of the area.

  • PDF

The Adoption of Risk Assessment Methodology in Exposure Assessment (근로자 노출평가제도 내 위험성평가 방법론의 적용)

  • Kim, Seung Won;Choi, Sangjun;Phee, Young Gyu;Kim, Kab Bae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.4
    • /
    • pp.482-492
    • /
    • 2015
  • Objectives: Exposure Assessment for workplace hazards where the exposure level is below occupational exposure limits(OELs) has been performed without considering either the degrees of risk or exposure levels and has failed to lead to intervention in many cases. The objective of this study was to suggest and test an application framework for risk assessment methodology under the current exposure assessment system in Korea. Materials: First, we investigated the exposure assessment systems in Korea and other countries. To adopt some risk assessment techniques, we also analyzed risk assessment systems and compared them to exposure assessment systems. A few suggestions were made. We held a public hearing during an industrial hygiene conference and took surveys using a questionnaire. Results: The first suggestion was to implement the risk assessment and exposure assessment through a "one-stop" system. In that case, one expected question would be who has been doing the jobs so far. In most cases, industrial hygiene consulting services or laboratories have been performing exposure assessment for business owners. Business owners are required to perform risk assessment. As two different groups of people will be required to implement two things in a one-stop system, they need to share information. As an information vehicle to share information, commonly filed survey checklists were suggested. The second suggestion was to categorize exposure level into four groups instead of the current binary divisions based on OELs. In the risk assessment system, exposure level is divided into four groups utilizing the cut-points of 10%, 50%, and 100% of OELs. The same schema can be adopted in the exposure assessment system and different levels of requirements can be assigned for each group. The third suggestion was regarding the regulation system. To provide the suggestions some thrust toward being implemented in the field, changes should be made in the legal system. Two different types of new exposure assessment result reporting forms were suggested. Some investigations such as an ergonomic survey are officially accepted as risk assessment under the current legal system. A few items were suggested to be included in the exposure assessment result reporting to be accepted as risk assessment. A pilot study in two small factories was performed and pointed out the strengths and weakness of our suggestions. Conclusions: Discussions and studies on the improvement of the exposure assessment system have been held for decades and no tangible changes have yet been made. We hope this result can help realize healthy lives for workers in Korea.

Development of Evaluation Index and Multi-layer Evaluation System for Quality Management of Elderly Long-term Care Institution (노인장기요양기관(시설급여) 평가의 품질관리를 위한 평가지표 개발 및 다층평가시스템 방안)

  • Lee, Sang-Jin;Kim, Yun-Jeong
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.11
    • /
    • pp.1015-1026
    • /
    • 2019
  • The purpose of this study is to develop evaluation indexes for improving the quality of long-term care institutions (facility salary) evaluation in the sense that the applicability and effectiveness of previous studies related to the development of evaluation indexes for long-term care facilities for elderly are insufficient. There was this. To this end, an analytical review of the 2018 long-term care institution (accommodation benefit) evaluation index, an analysis of Japan's elderly long-term care home evaluation index, and the elderly long-term care facility workers in Korea and the special care home for the elderly in Japan FGI on evaluation indicators and evaluation system was conducted. Based on the results of the research, evaluation indicators were developed in terms of supporting users to receive high quality services. The characteristics of the elderly, that is, the characteristics of elderly diseases that are difficult to maintain and improve, the direction and transparency of institutional operation, and the need for terminal care were reflected. Forty-three evaluation indicators were presented, covering institutional operations, environment and safety, beneficiary rights protection, payroll process, and payroll results. In addition, we proposed a four-step multi-level evaluation system that can improve the efficiency of the evaluation process by improving the redundant and unnecessary evaluation process.

Estimation of an Occupational Exposure Limit for Multi-Walled Carbon Nanotubes Manufactured in Korea (국내 일부 다중벽탄소나노튜브의 직업노출기준 추정)

  • Kim, Jong Bum;Kim, Kyung Hwan;Choi, Byung-Gil;Song, Kyung Seuk;Bae, Gwi-Nam
    • Journal of Environmental Science International
    • /
    • v.25 no.4
    • /
    • pp.505-516
    • /
    • 2016
  • With the development of nanotechnology, nanomaterials are used in various fields. Therefore, the interest regarding the safety of nanomaterial use is increasing and much effort is diverted toward establishment of exposure assessment and management methods. Occupational exposure limits (OELs) are effectively used to protect the health of workers in various industrial workplaces. This study aimed to propose an OEL for domestic multi-walled carbon nanotubes (MWCNTs) based on animal inhalation toxicity test. Basic procedure for development of OELs was examined. For OEL estimation, epidemiological study and quantitative risk assessment are generally performed based on toxicity data. In addition, inhalation toxicity data-based no observed adverse effect level (NOAEL) and benchmark dose (BMD) are estimated to obtain the OEL. Three different estimation processes (NEDO in Japan, NIOSH in USA, and Baytubes in Germany) of OELs for carbon nanotubes (CNTs) were intensively reviewed. From the rat inhalation toxicity test for MWCNTs manufactured in Korea, a NOAEL of $0.98mg/m^3$ was derived. Using the simple equation for estimation of OEL suggested by NEDO, the OEL of $142{\mu}g/m^3$ was estimated for the MWCNT manufacturing workplace. Here, we used test rat and Korean human data and adopted 36 as an uncertainty factor. The OEL for MWCNT estimated in this work is higher than those ($2-80{\mu}g/m^3$) suggested by previous investigators. It may be greatly caused by different physicochemical properties of MWCNT and their dispersion method and test rat data. For setting of regulatory OELs in CNT workplaces, further epidemiological studies in addition to animal studies are needed. More advanced technical methods such as CNT dispersion in air and liquid should be also developed.

Determination of Design Basis for a Storage System for Spent Fuel in Korea (국내 사용후핵연료 저장시스템의 설계기준 설정 인자 고찰)

  • Yoon, Jeong-Hyoun;Lee, Eun-Yong;Woo, Sang-In;Kim, Tae-Man
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.2
    • /
    • pp.113-119
    • /
    • 2011
  • Safe operation and maintenance of engineered dry storage systems for spent fuel from nuclear power plants basically depends on adequately adopted design requirements. The most important design target of the system are those which provide the necessary assurances that spent fuel can be received, handled, stored and retrieved without undue risk to health and safety of workers and the public. To achieve these objectives, the design of the system incorporates features to remove spent fuel residual heat, to provide for radiation protection, and to maintain containment over the lifespan of the system as specified in the design specifications. The features also provide for all possible anticipated operational occurrences and design basis events in accordance with the design basis as guided by the designated regulations. The general performance requirements of a projected storage system are introduced in this paper. The storage system is designed to store fuel assemblies in associated with designated regulatory requirements. Small increases/decreases in maximum burnup can be adjusted with cooling time. These variations are compensated for by a corresponding small site-specific increase/decrease in the design basis-cooling period, as long as the maximum heat load and radioactivity of loaded fuel assemblies are met. Generic design basis events considered for the storage system are summarized. Shielding and radiological requirements along with mechanical and structural are derived in this study.

A Study on the Job Stress of Opticians (안경사 직무스트레스에 관한 연구)

  • Hwang, Hae-Young;Kim, Hyun-Mok;Kim, In-Soo;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Purpose: This study is conducted to evaluate the job stressors for opticians in Ulsan city. Methods: We investigated job stress of 180 opticians working in Ulsan. The results of this study from The Korean standard job stressors assessment tool developed by Korea occupational safety and health agency (KOSHA) was compared with Korean reference value. The questionnaire on the social, demographic characteristics of opticians was also used to find the factors affecting to job stressors by using multiple linear regression analysis. Results: Among the eight fields of stressors, the interpersonal conflict (the median value; 33.4, the measurements; men; 38.8, women; 41.5) and company culture (the median; 41.7, the measurements; men; 47.4, women; 49.3) were higher than the median value of the Korean workers. By multiple linear regression analysis, the significant factors to the interpersonal conflict were the duty, working hours, unmarried, average salary. In terms of the company culture, last school, rest day of month, job career, average salary and working hours were significantly associated to the score of company culture. Conclusions: Based on the results, important factor in the formation of a positive organizational culture through to improve treatment of opticians investigation and mutual horizontal communication systems in the workplace for the manage on interpersonal conflict and company culture.

Calculation of Derived Investigation Levels for Uranium Intake (우라늄 섭취의 유도조사준위 산출)

  • Lee, Na-Rae;Han, Seung-Jae;Cho, Kun-Woo;Jeong, Kyu-Hwan;Lee, Dong-Myung
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.68-77
    • /
    • 2013
  • Derived Investigation levels(DILs) were calculated to protect the workers from the effects of both radiological hazard and chemical toxicity by uranium intake. Investigation Levels(ILs) of committed effective dose of 2 mSv $y^{-1}-6$ mSv $y^{-1}$ and uranium concentration of 0.3 ${\mu}g$ $g^{-1}$ in kidney, based on Korean Nuclaer Safety Act, Korean Occupational Safety and Health Act and current scientific studies of uranium intake were assumed. DILs of radiological hazard and chemical toxicity were then calculated based on the concentration of uranium in air of workplace, the lung monitoring and urine analysis, respectively. As a result, in case of the nuclear fuel fabrication plant where 3.5% enriched uranium is handled, derived investigation level(DIL) for the control of the concentration of uranium in the air of workplace assumed with 15-min acute inhalation was 0.6 mg $m^{-3}$ for all types of uranium. DILs for the control of the average concentration of uranium in air of workplace, assuming an 8-hour workday, were 15.21 ${\mu}g$ $m^{-3}$ of Type F uranium, 0.41-1.23 Bq $m^{-3}$ and 0.13-0.39 Bq $m^{-3}$ for Type M and Type S uranium, respectively. DILs for the lung monitoring assumed with a period of 6-month interval were 0.37-1.11 Bq and 0.39-1.17 Bq in acute and chronic inhalation for Type M, respectively and 0.30- 0.91 Bq and 0.19-0.57 Bq in acute and chronic inhalation for Type S, respectively. Since a detection limit of typical germanium detector for the measurement of 235U activity is 4 Bq, DILs calculated for the lung monitoring were not appropriate. DILs for urine analysis, for which an interval was assumed to be 1 month, were 14.57 ${\mu}g$ $L^{-1}$ based on chemical toxicity after acute inhalation. In addition, acute and chronic inhalation of Type M were calculated 2.85-8.58 ${\mu}g$ $L^{-1}$ and 1.09-3.27 ${\mu}g$ $L^{-1}$ based on the radiological hazard, respectively.

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.

A Study on Relationship between Physical Elements and Tennis/Golf Elbow

  • Choi, Jungmin;Park, Jungwoo;Kim, Hyunseung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.3
    • /
    • pp.183-196
    • /
    • 2017
  • Objective: The purpose of this research was to assess the agreement between job physical risk factor analysis by ergonomists using ergonomic methods and physical examinations made by occupational physicians on the presence of musculoskeletal disorders of the upper extremities. Background: Ergonomics is the systematic application of principles concerned with the design of devices and working conditions for enhancing human capabilities and optimizing working and living conditions. Proper ergonomic design is necessary to prevent injuries and physical and emotional stress. The major types of ergonomic injuries and incidents are cumulative trauma disorders (CTDs), acute strains, sprains, and system failures. Minimization of use of excessive force and awkward postures can help to prevent such injuries Method: Initial data were collected as part of a larger study by the University of Utah Ergonomics and Safety program field data collection teams and medical data collection teams from the Rocky Mountain Center for Occupational and Environmental Health (RMCOEH). Subjects included 173 male and female workers, 83 at Beehive Clothing (a clothing plant), 74 at Autoliv (a plant making air bags for vehicles), and 16 at Deseret Meat (a meat-processing plant). Posture and effort levels were analyzed using a software program developed at the University of Utah (Utah Ergonomic Analysis Tool). The Ergonomic Epicondylitis Model (EEM) was developed to assess the risk of epicondylitis from observable job physical factors. The model considers five job risk factors: (1) intensity of exertion, (2) forearm rotation, (3) wrist posture, (4) elbow compression, and (5) speed of work. Qualitative ratings of these physical factors were determined during video analysis. Personal variables were also investigated to study their relationship with epicondylitis. Logistic regression models were used to determine the association between risk factors and symptoms of epicondyle pain. Results: Results of this study indicate that gender, smoking status, and BMI do have an effect on the risk of epicondylitis but there is not a statistically significant relationship between EEM and epicondylitis. Conclusion: This research studied the relationship between an Ergonomic Epicondylitis Model (EEM) and the occurrence of epicondylitis. The model was not predictive for epicondylitis. However, it is clear that epicondylitis was associated with some individual risk factors such as smoking status, gender, and BMI. Based on the results, future research may discover risk factors that seem to increase the risk of epicondylitis. Application: Although this research used a combination of questionnaire, ergonomic job analysis, and medical job analysis to specifically verify risk factors related to epicondylitis, there are limitations. This research did not have a very large sample size because only 173 subjects were available for this study. Also, it was conducted in only 3 facilities, a plant making air bags for vehicles, a meat-processing plant, and a clothing plant in Utah. If working conditions in other kinds of facilities are considered, results may improve. Therefore, future research should perform analysis with additional subjects in different kinds of facilities. Repetition and duration of a task were not considered as risk factors in this research. These two factors could be associated with epicondylitis so it could be important to include these factors in future research. Psychosocial data and workplace conditions (e.g., low temperature) were also noted during data collection, and could be used to further study the prevalence of epicondylitis. Univariate analysis methods could be used for each variable of EEM. This research was performed using multivariate analysis. Therefore, it was difficult to recognize the different effect of each variable. Basically, the difference between univariate and multivariate analysis is that univariate analysis deals with one predictor variable at a time, whereas multivariate analysis deals with multiple predictor variables combined in a predetermined manner. The univariate analysis could show how each variable is associated with epicondyle pain. This may allow more appropriate weighting factors to be determined and therefore improve the performance of the EEM.

Microbiological Hazard Analysis of Hot Pepper Farms for the Application of Good Agricultural Practices (GAP) System (농산물우수관리제도 (GAP) 적용을 위한 고추농가의 미생물학적 위해도 평가)

  • Nam, Min-ji;Heo, Rok-Won;Lee, Won-Gyeong;Kim, Kyeong-Yeol;Chung, Do-Yeong;Kim, Jeong-Sook;Shim, Won-Bo;Chung, Duck-Hwa
    • Journal of agriculture & life science
    • /
    • v.45 no.6
    • /
    • pp.163-173
    • /
    • 2011
  • The objective of this study was to determine microbiological risk factors in hot pepper farms for the application of good agricultural practices (GAP). Samples were collected from cultivation environments and utensils, plants, workers, and air at 3 hot pepper farms located in Cheongsong, Korea and were tested to detect sanitary indications [aerobic plate bacteria (APC), coliform, and Escherichia coli], foodborne pathogens, and fungi. APC, coliform, and fungi were detected at the levels of 0.7~6.2, 0.2~4.7, and 0.4~4.3 log CFU, respectively, in the three farms. Four (4.4%; l leaf, l irrigation water, and 2 soil) of 90 samples collected were revealed to be E. coli positives. For foodborne pathogens, Staphylococcus aureus was only detected at $1.0log\;CFU/100cm^2$ in the worker's cloth of B farm, and Bacillus cereus was detected at the levels 1.0~2.5 log CFU in the cultivation environments and utensils and worker of B and C farms. However, other pathogens were not detected. The results demonstrated potential microbiological risks for hot pepper cultivated in the farms. Therefore, a management system to minimize the microbial risk such as GAP is required to ensure the safety of hot pepper.