• Title/Summary/Keyword: won point and rak point

Search Result 12, Processing Time 0.025 seconds

Effect of Electroacupuncture Applied to the Won Point and Rak Point in the Rat Model of Ankle Sprain Pain (원락(原絡) 배혈(配穴) 전침 자극이 백서의 족과 염좌(捻挫) 통증에 미치는 영향(影響))

  • Kim, Sun-Young;Koo, Sung-Tae;Kim, Kyoung-Sik;Sohn, In-Cheul
    • Korean Journal of Acupuncture
    • /
    • v.22 no.1
    • /
    • pp.7-21
    • /
    • 2005
  • Objectives : In the present study, the effect of electroacupuncture (EA) applied to SI6 and won-rak point on the ankle sprain model was examined. A common source of persistent pain in humans is the lateral ankle sprain. Methods : To model this condition, the rat's right ankle was bent repeatedly, overextending lateral ligaments, for 4 min under enflurane anesthesia. The rat subsequently showed swelling of the ankle and a reduced stepping force of the affected limb for the next several days. The reduced stepping force of the limb was presumably due to a painful ankle. EA was applied to the several acupuncture point on the contralateral forelimb for 30 min under gaseous anesthesia. After the termination of EA, behavioral tests measuring stepping force and Paw volume were Periodically conducted during the next 4 h and 18 h respectively. Results : EA applied to $SI_6$ with won-rak point produced more powerful improvement of stepping force of the sprained foot than to $SI_6$ alone lasting for at least 4 h. However, neigher $KI_4$ point nor $BL_{64}$ point produced any significant increase of weight bearing force. The improvement of stepping pressure was interpreted as an analgesic effect. The analgesic effect was specific to the acupuncture point since the analgesic effort on the ankle sprain pain model could not be mimicked by EA applied to $KI_4$ or $BL_{64}$. In addition, EA applied to $SI_6$ with won-rak combination point showed inhibitory effect on the paw edema induced by ankle sprain. Also, COX-2 protein expression increased by ankle sprain were suppressed by the EA stimulation. Conclusion : These data suggest that EA with won-rak combination point produces a more potent analgesic effect on the ankle sprain pain model in the rat and that EA with won-rak combination point induced anti-inflammatory effect through the suppression of COX-2 protein expression.

  • PDF

Real-Time Face-Detection Based on Multiple Color-Spaces and Multiple Thresholds for Distance Measurement Between Speaker and Smart-Phone (화자(話者)와 스마트폰의 거리 측정을 위한 다중 색 좌표계와 다중 임계치 기반 실시간 얼굴검출)

  • Lee, Jae-Won;Kwon, Goo-Rak;Hong, Sung-Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.4
    • /
    • pp.481-493
    • /
    • 2011
  • As the development of mobile devices, mobile phones are equipped with many features. Video-call feature is one of them. In this paper, we present distance measurement between speaker and smart-phone using multiple color spaces and multiple thresholds. first, detect face based on skin color information. and second, measure distance between speaker and smart-phone using the detected face region. Especially, the first considering point in the development of face area detection is real-time processing and the second point is robustness to solve the problems of face detection errors due to rapid change of object movement, lighting and background between adjacent frames.

Pointwise Estimation of Density of Heteroscedastistic Response in Regression

  • Hyun, Ji-Hoon;Kim, Si-Won;Lee, Sung-Dong;Byun, Wook-Jae;Son, Mi-Kyoung;Kim, Choong-Rak
    • The Korean Journal of Applied Statistics
    • /
    • v.25 no.1
    • /
    • pp.197-203
    • /
    • 2012
  • In fitting a regression model, we often encounter data sets which do not follow Gaussian distribution and/or do not have equal variance. In this case estimation of the conditional density of a response variable at a given design point is hardly solved by a standard least squares method. To solve this problem, we propose a simple method to estimate the distribution of the fitted vales under heteroscedasticity using the idea of quantile regression and the histogram techniques. Application of this method to a real data sets is given.

A Study on the Optimal Design of TMD According to the Shape of Large Spatial Structures Part 2 (대공간 구조물의 형상에 따른 TMD 최적 설계에 관한 연구 Part 2)

  • Bae, Seok-Hong;Lee, Young-Rak;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.83-91
    • /
    • 2020
  • In this study, a tuned mass damper(TMD) was installed to control the displacement response to earthquakes by generalizing to six analysis models according to the shape of the upper structure based on the case of various large spatial structures around the world. The six analysis models are ribbed type, latticed type, elliptical type, gable type, barrel type, and stadium type composed of 3D arch trusses. In this paper, ribbed type, latticed type and elliptical type were analyzed. The mass of each TMD was set to 1% of the total structural mass. Result of analyzing the optimal number and position of the analysis model, the displacement response control was the most excellent in the model with 6 and 8 TMDs, and the displacement response decreased in most cases. The displacement response control was better with installing the TMD at the edge point than focusing the TMD at the center of the analysis model. However, when 10 or more TMDs are installed or concentrated in the center, large loads intensively act on the structure, resulting in increased displacement. Therefore, although it is slightly different depending on the shape, it is judged that the displacement response control is the best to install 6 and 8 TMDs at the close to the edge point.

A Study on the Optimal Design of TMD According to the Shape of Large Spatial Structures Part 1 (대공간 구조물의 형상에 따른 TMD 최적 설계에 관한 연구 Part 1)

  • Bae, Seok-Hong;Lee, Young-Rak;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.73-81
    • /
    • 2020
  • In this study, a tuned mass damper(TMD) was installed to control the displacement response to earthquakes by generalizing to six analysis models according to the shape of the upper structure based on the case of various large spatial structures around the world. The six analysis models are ribbed type, latticed type, elliptical type, gable type, barrel type, and stadium type composed of 3D arch trusses. In this paper, ribbed type, latticed type and elliptical type were analyzed. The mass of each TMD was set to 1% of the total structural mass. Result of analyzing the optimal number and position of the analysis model, the displacement response control was the most excellent in the model with 6 and 8 TMDs, and the displacement response decreased in most cases. The displacement response control was better with installing the TMD at the edge point than focusing the TMD at the center of the analysis model. However, when 10 or more TMDs are installed or concentrated in the center, large loads intensively act on the structure, resulting in increased displacement. Therefore, although it is slightly different depending on the shape, it is judged that the displacement response control is the best to install 6 and 8 TMDs at the close to the edge point.

A Study of Mac(脈)-Theory and Change of Mac(脈)-Diagnosis in Whang Di Nei Qing(黃帝內經) (황제내경(黃帝內經)의 맥(脈) 이론(理論)과 진맥법(診脈法)의 변화(變化)에 관(關)한 연구(硏究))

  • Ra, Kyoung-Chan;Park, Hyun Kook
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.2 no.1
    • /
    • pp.73-105
    • /
    • 1993
  • To say nothing of the orient and the west, the human beings discover the method of Jin Mac(診脈) by the way that observe disease. But oriental medicine devise special method of Jin Mac(診脈) in the study of Kyoung Mac(經脈). Although sip-ei Kyoung Mac Jin(十二經脈診), Sam Bu Gu Who Jin(三部九候診), In Young Mac Gu Jin(人迎脈口診), Chon Kwan Chuck Jin(寸關尺診) namely Yuk Bu Jung Wee Jin Mac (六部定位診脈) that is used today are devised, it has changed naturally by the changing treatment and the introduction of Yuin Yang(陰陽) and five element(五行). Many methods dg Jin Mac(診脈), it had not developped successing alternative, it had developped of declined by it's own way. 1. Results for the birth of Mac(脈) 1) Mac(脈), it means Kyoung Mac(經脈), at first entirelly Mac(脈), is seized a blood vessel that flows in the body. As presumed today, after finding many acupunture point, a general idea of Mac(脈) is not maked by the line that connect point and point, it connect between acupunture point and acupunture point. 2) Like blood flows in Hyul Mac(血脈), Gie(氣) flows in Kyoung Mac(經脈). The two things relate deeply each other. In a general idea or actrally Kyoung Rak(經洛), the two things sometimes accord, sometimes seperate, sometimes mix alternative. 3) Hyul Mac(血脈) and Kyoung Mac(經脈), we call it Mac(脈) entirely Kyoung Mac(經脈), is a way that manifest disease through Kyoung Mac(經脈) or a boundary that disease belongs to it method of Mac Jin(脈診) individual that disease of Kyoung Mac(經脈) is diagnosed by the jumping situation of Hyul Mac(血脈). 4) In method of Moxa, athough the pathology and the diagnostic of Mac(脈) are created by finding Mac(脈). Finding acupunture have opportunitty fot Mac Jin(脈診) and treatment. 2. Results of Kyoung Mac Mac Jin(經脈脈診) 1) In theory of kyoung Rak(經洛), disease are resumed for malfunction of Young Wee(榮衛) that flows in Kyung Rak(經洛). So to speak, in treatment of Kyoung Rak area, the purpose of diagnosis observe the situation of disease and cause. For fitting the purpose of diagnosis, the dead had esatablised four-diagnosis method mangMunMnnJeul(望聞問切), in four-diagnosis(四診法), the core is Mac Jin(脈診). 2) sip-ei Kyoung Mac Mac Jin(十二經脈診) had existed as Kyoung Mac Mac Jin(經脈脈診), it precedes Sam Bu Gu Who Jin(三部九候診). In Young Ki Gu Mac(人迎脈口診). 3) Although Bu Yang Mac(趺陽脈), So Um Mac(少陰脈) is a part of Sip-ei Kyoung Mac(十二經脈診), they developped especially because they located in the point of Won Hyul(原穴) and they are convenient for diagnose. 4) Sip-ei Kyoung Mac Mac Jin(十二經脈診), which belongs to Bu Yang Mac(趺陽脈) and So Urn Mac(少陰脈), is not important for the comming age medical books compared with Mac Kyoung(脈經). 3. Results gor Sam Bu Gu Who Jin(三部九候診) 1) Mac Jin(脈診) of Sam Bu Gu Who(三部九候), which is noted in the theory of Sam Bu Gu Who(三部九候診) of So Mun(素問), belongs to Kyoung Mac Mac Jin's(經脈脈診) geneology, Sip-ei Kyoung Mac Mac Jin(十二經脈診) is arranged, simplicated by the idealogy three talents(三才思想) in the heaven and the earth. 2) What Sam Bu Gu Jin(三部九候診) is regardded as very important in So Mun(素問), the editor of So Mun(素問) recognize the meaning that one discover disease early in this method of diagnosis. 3) After Young chu(靈樞), Nan Kyoung(難經) it is lacked the method of Sam Bu Gu Who Jin(三部九候診) in the books that treatment has changed. Sam Bu Gu Who Jin(三部九候診) based on actually clinic appropriate. 4. results for In Young Mac Gu Jin(人迎脈口診) 1) In Young Mac Gu Jin(人迎脈口診) is the method of comparative Mac Jin(脈診) according to the theory of Yin Yang(陰陽), it is presumed after Sam Bu Gu Who Jin(三部九候診), it had perished in parallel with the development of the theory of five elelment(五行). The development of the acupunture, the perishment of the treatment of negative(刺絡). 2) In Young Mac Gu Jin(人迎脈口診), Wang Suk Wha(王叔和) recreated that the left is In Young(人迎), the right is Kie Gu(氣口). In future generations by Jin Mu Taek(陳無擇) who is the writer of Sam In Bang(三因方). In Young Mac Gu Jin(人迎脈口診) is a measure for disease which classify it's inside and outside cause. 5. Results for Chon Gu Mac Jin(寸口脈診) 1) What we say Mac Jin(脈診) of Chon Gu(寸口) two means are used in commn. First case, we simply say the area of Chon Gu(寸口), second case, we say Chon Kwan Chuk Jin(寸口尺診) reducingly. Chon Gu(寸口) is the area which is the radial artery of wrist joint. What we attemp diagnose by only Chon Gu Mac(寸口脈), it is clearly shoued in the method of Nan Kyoung, five Nan(難經五難). 2) Because Jin Mac(診脈) is made in only Chon Gu(寸口), that is the area in which is concentated Kyoung Kee(經氣). That is the birth of Jin Kee(眞氣) and Jin Kee(眞氣) is related with disease. We can diagnose disease by taking Chon Gu(寸口). 3) Chuk Jin(尺診) in Nae Kyoung(難經) have two things. One is Il Chuk(一尺), the other is Chon Kwan Chu(寸關尺). 4) Chuk Chon Jin(尺寸診) is the method which diagnose the difference of point and the condition of Mac(脈) by dividing a part of Chuk(尺) in the area of Chon Gu(寸口). In Chon Gu Jin(寸口診), by introducing the theory of Yin Yang(陰陽), the method of Chon Gu Jin(寸口診) is developed by chon Gu Jin(寸口診). 5) What Chuk Kwan Chon Jin(寸關尺診) is that area of the Chon Gu(寸口) are divided fot three point, we can diagnose. By consulting Sam Bu Gu Who Jin(三部九候診), developping of the method of acupunture, utilzing the theory of five element(五行) it is devised by concentrating way of thinking of the method mac Jin(脈診) exiting. 6) Chon Kwan Chuk Jin MaC(寸關尺診脈) begin from Nae Kyoung(內徑) exiting. After Nan Kyoung(內徑), spread out widely from Mac Kyoung(脈診) of Wang Suk wha(王叔和), the future medicins followed it. Yang Hyun Jo(楊玄操) and established Chon Kwan Chuk Jin(寸關尺診) which is used widely today. This right and left Chon Kwan Chuk Jin(寸關尺診), we call it method of Yuk Bu Jung Wee Jin Mac(六部定位診脈). 7) We can think the base which presume the arrangement of the viscera for Chon Kwan Chuk(寸關尺) of the right and the left. 8) The origin, which seperate the right and the left of Mac(脈), is showed at the treory of Ji Jin Yo Dae(至眞要大論) in So Mun(素問) which Chon Chuk(寸尺) seperate the right and the left. But the method of diagnosis in Nan Kyoung(難經) have no seperation the fight and the left. Otherwise this. there is clearly writtened the seperation for the right origin of the method of Yuk Bu Jung Wee Jin Mac(六部定位診脈) seek for Cang Gong(倉公). 9) Yang Hyun Jo(楊玄操) notice that the Chuk(尺) is mentioned for Sam Cho(三焦) in the method of Mac Kyuong(脈經), Sim Po Kyung(心包經) which put together with Sam Cho(三焦) allot on this, he had established the method of Yuk Bu Jung Wee Jin Mac(六部定位診脈). 10) On the method of Paen Jak Yin Yang Mac(扁鵲陰陽脈) in Mac Kyoung(脈經), equal article exist with the theory of Pyung In Kee Sang(平人氣象論) in So Mun(素問). When Wang Suk Wha(王叔和) write Mac Kyung(脈經), we can presume that the book of Mac(脈) which Paen Jak(扁鵲) had experienced the origin have exited besides So Mun(素問), Young Chu(靈樞). If so he must be make Chon Kwan Chuk Jin(寸關尺診) very fairly standard. So Nae Kyoung(內經), which must be fllowed the method of Paen Jak Mac(扁鵲脈), do the method diagnosis of Chon Kwan Chuk(寸關尺), diagnise of disease and treat.

  • PDF

Ultra-precision Machining of Space Telescope IR Camera Lens (초정밀 가공기를 이용한 적외선 우주망원경용 렌즈의 절삭가공기술개발)

  • Yang, Sun-Choel;Kim, Geon-Hee;Kim, Hyo-Sik;Shin, Hyun-Su;Hong, Kweon-Hee;Yoo, Jong-Sin;Kim, Dong-Rak;Park, Soo-Jong;Nam, Uk-Won
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.4 no.2
    • /
    • pp.31-36
    • /
    • 2005
  • Machining technique for optical crystals with single point diamond turning tool is reported in this paper. The main factors influencing the machined surface quality are studied and regularities of machining process are drawn. Optical crystals have been known to more and more important applications in the field of modern optics. Ge is more brittle material of poor machinability. The traditional machining method is polishing which has many shortcomings such as low production efficiency, poor ability to be automatically controlled and edge effect of the workpiece. The purpose of our research is to find the optimum machining conditions for ductile cutting of Ge and apply the SPDTM technique to the manufacturing of ultra precision optical components of Ge. As a result, the surface roughness is the best when cutting speed is 180m/min, feed rate is 2mm/min, depth of cut is $0.5{\mu}m$ and nose radius of tool is 0.8mm.

  • PDF

Prediction of Mechanical and Electrical Properties of NiO-YSZ Anode Support for SOFC from Quantitative Analysis of Its Microstructure (미세조직 정량 분석을 통한 고체산화물연료전지용 NiO-YSZ 연료극 지지체의 기계적/전기적 성능 예측)

  • WAHYUDI, WANDI;KHAN, MUHAMMAD SHIRJEEL;SONG, RAK-HYUN;LEE, JONG-WON;LIM, TAK-HYOUNG;PARK, SEOK-JOO;LEE, SEUNG-BOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.5
    • /
    • pp.521-530
    • /
    • 2017
  • Improving the microstructure of NiO/YSZ is one of several approaches used to enhance the electrical and mechanical properties of an anode support in Solid Oxide Fuel Cells (SOFCs). The aim of the work reported in this paper was to predict the relationship between these microstructural changes and the resulting properties. To this end, modification of the anode microstructure was carried out using different sizes of Poly (Methyl Methacrylate) (PMMA) beads as a pore former. The electrical conductivity and mechanical strength of these samples were measured using four-probe DC, and three-point bend-test methods, respectively. Thermal etching followed by high resolution SEM imaging was performed for sintered samples to distinguish between the three phases (NiO, YSZ, and pores). Recently developed image analysis techniques were modified and used to calculate the porosity and the contiguity of different phases of the anode support. Image analysis results were verified by comparison with the porosity values determined from mercury porosimetry measurements. Contiguity of the three phases was then compared with data from electrical and mechanical measurements. A linear relationship was obtained between the contiguity data determined from image analysis, and the electrical and mechanical properties found experimentally. Based upon these relationships we can predict the electrical and mechanical properties of SOFC support from the SEM images.

THE STUDY ON THE PROGNOSIS OF DENTAL IMPLANTS WHICH HAS BEEN INSTALLED AFTER MAXILLOFACIAL TRAUMA (악안면 외상 후 식립된 임플란트의 예후에 관한 연구)

  • Jeon, Ha-Ryong;Kim, Jong-Won;Hong, Jong-Rak;Kim, Chang-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.4
    • /
    • pp.348-351
    • /
    • 2006
  • Purpose The purpose of this study was to evaluate the success rate of dental implant on post-traumatic region to rehabilitate missing teeth. Patients and Methods 5 patients who had been treated due to maxillofacial trauma during 2000 to 2004 at samsung medical center were selected for this study. 22 dental implants were installed to them for restoring missing teeth. The success rate of these dental implants was evaluated with criteria by T. Albrektsson. We divided installed 22 implants into 2 categories. One category consisted rough surface implants group and smooth surface implants group. And the other category consisted more healing group and less healing group. The healing time was calculated from point of trauma. Results The success rate of dental implants is 68.2% that is lower than other studies because of poor vascularity of bone bed and mechanical stress according to trauma. Rough surface implants group and More healing group showed superior success rate to others. (P < 0.05). Conclusion We found that to increase success rate, it may need rough surface implants and longer healing period.

Implementation of a 2-axis Additional Axes Strategy on a 6-axis Articulated Robot for Improving Welding Process Efficiency (2축 부가 축을 이용한 6축 수직 다관절로봇의 용접공정효율 증대를 위한 연구)

  • Hong, Jun-Rak;Jo, Hyeon-Min;Chung, Won-Jee;Park, Seung-Kyu;Noh, Seong-Hoon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.6
    • /
    • pp.55-62
    • /
    • 2017
  • This paper aims to realize additional axes, which increase the processing efficiency of a robot by controlling in harmful environments. Ultimately, this is to create time and energy savings in industrial sites with 6-axis articulated welding robots (RS2). Using $RecurDyn^{(R)}$ a simulation technique is applied. The motion paths of the welding rod are compared for two cases in order to verify the necessity of the additional axes: 1) when there are no additional axes and 2) when there are additional axes during welding using the RS2. For this purpose, the angle variations of the RS2 axes required for the simulation are compared, on the assumption that each of the four points of the welding bed installed on the additional axes of the welding rod in $Solidworks^{(R)}$ is point-welded. Then, actual additional axes equipment is grafted on to the RS2 and the process times compared using $LabVIEW^{(R)}$.