• Title/Summary/Keyword: with-without analysis

Search Result 11,856, Processing Time 0.047 seconds

Ischemic Preconditioning and Its Relation to Glycogen Depletion (허혈성 전처치와 당원 결핍과의 관계)

  • 장대영;김대중;원경준;조대윤;손동섭;양기민;라봉진;김호덕
    • Journal of Chest Surgery
    • /
    • v.33 no.7
    • /
    • pp.531-540
    • /
    • 2000
  • Baclgrpimd; Recent studies have suggested that the cardioprotective effect of ischemic preconditioning(IP) is closely related to glycogen depletion and attenuation of intracellular acidosis. In the present study, the authors tested this hypothesis by perfusion isolated rabbit hearts with glucose(G) is closely related to glycogen depletion and attenuation of intracellular acidosis. In the present study, the authors tested this hypothesis by perfusion isolated rabbit hearts with glucose(G)-free perfusate. Material and Method; Hearts isolated from New Zealand white rabbits(1.5~2.0 kg body weight) were perfused with Tyrode solution by Langendorff technique. After stabilization of baseline hemodynamics, the hearts were subjected to 45 min global ischemia followed by 120 min reperfusion with IP(IP group, n=13) or without IP(ischemic control group, n=10). IP was induced by single episode of 5 min global ischemia and 10 min reperfusion. In the G-free preconditioned group(n=12), G depletion was induced by perfusionwith G-free Tyrode solution for 5 min and then perfused with G-containing Tyrode solution for 10 min; and 45 min ischemia and 120 min reperfusion. Left ventricular functionincluding developed pressure(LVDP), dP/dt, heart rate, left ventricular end-distolic pressure(LVEDP) and coronary flow (CF) were measured. Myocardial cytosolic and membrane PKC activities were measured by 32P-${\gamma}$-ATP incorporation into PKC-specific peptide and PKC isozymes were analyzed by Western blot with monoclonal antibodies. Infarct size was determined by staining with TTC(tetrazolium salt) and planimetry. Data were analyzed by one-way analysis of variance (ANOVA) and Turkey's post-hoc test. Result ; In comparison with the ischemic control group, IP significantly enhanced functional recovery of the left ventricle; in contrast, functional significantly enhanced functional recovery of the left ventricle; in contrast, functional recovery were not significantly different between the G-free preconditioned and the ischemic control groups. However, the infarct size was significantly reduced by IP or G-free preconditioning(39$\pm$2.7% in the ischemic control, 19$\pm$1.2% in the IP, and 15$\pm$3.9% in the G-free preconditioned, p<0.05). Membrane PKC activities were increased significantly after IP (119%), IP and 45 min ischemia(145%), G-free [recpmdotopmomg (150%), and G-free preconditioning and 45 min ischemia(127%); expression of membrane PKC isozymes, $\alpha$ and $\varepsilon$, tended to be increased after IP or G-free preconditioning. Conclusion; These results suggest that in isolated Langendorff-perfused rabbit heart model, G-free preconditioning (induced by single episode of 5 min G depletion and 10 min repletion) colud not improve post-ischemic contractile dysfunction(after 45-minute global ischemia); however, it has an infarct size-limiting effect.

  • PDF

A Prospective Randomized Trial Comparing the Seciuence of Adiuvant Chemotherapy and Radiotherapy following Curative Resection of Stage II, III Rectal Cancer (직장암의 근치적 수술 루 방사선치료와 화학요법의 순서에 대한 고찰 -전향적 무작위 3상 임상연구 중간 결과 보고-)

  • Kim Kyoung Ju;Kim Jong Hoon;Choi Eun Kyung;Chang Hyesook;Ahn Seung Do;Lee Je Hwan;Kim Jin Cheon;Yu Chang Sik
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.17-25
    • /
    • 2000
  • Purpose : To evaluate the side effects, pattern of failure, and survival rate according to the sequence of postoperative adjuvant radiotherapy and chemotherapy, patients with stages II and III rectal cancer who had undergone curative resection were randomized to 'early radiotherapy group (arm I)' or' late radiotherapy group (arm II)', then we intend to determine the most effective sequence of the radiotherapy and chemotherapy. Materials and Methods . From January 1996 to March 1999, 313 patients with curatively resected stages II and III rectal cancer have been randomized to' early' or' late' radiation therapy group and received combined chemotherapy (5-FU 375 mg/m$^{2}$/day, ieucovorin 20 mg/m$^{2}$, IV bolus daily Dl-5, 8 cycles) and radiation therapy (whole pelvis with 45 Gy/25 fractions/s weeks). Arm I received radiation therapy from day 1 with first cycle of chemotherapy and arm II received radiation therapy from day 57 with third cycle of chemotherapy after completion of first two cycles. Preliminary analysis was peformed with 228 patients registered up to Jun 1998. Two out of the 228 patients were excluded because of double primary cancer. Median follow-up period was 23 months. Results :Local recurrence occurred in 11 patients (9.7$\%$) for arm I and 9 patients (8$\%$) for arm 11. There was no significant difference between both groups ( p=0.64). However, distant metastasis was found in 22 patients (19.5$\%$) for arm I and 35 patients (31.0$\%$) for arm II and which showed statistically significant difference between the two groups ( p=0.046). And neither 3-year disease-free survival (70.2$\%$ vs 59.2$\%$, p=0.2) nor overall survival (89.4$\%$ vs 88.0$\%$, p=0.47) showed significant differences. The incidence of leukopenia during radiation therapy and chemotherapy was 78.3$\%$ and 79.9$\%$ respectively but leukopenia more than RTOG grade 3 was only 2.1$\%$ and 6.0$\%$ respectively. The incidence of diarrhea more than 10 times per day was significantly higher in the patients for arm I than for arm II (71.2$\%$ vs 41.6$\%$, p=0.02) but this complication was controlled with supportive cares. Conclusion : Regardless of the sequence of postoperative adjuvant radiation therapy and chemotherapy after curative resection for rectal cancer, local recurrence rate was low with combined chemoradlotherapy. But distant metastasis rate was lower in early radiation therapy group than in late radiation therapy group and the reason is unclear. Most patients completed these treatments without severe complication, so these were thought to be safe treatments but the treatment compliance should be improved.

  • PDF

Resolution of the Triacylglycerols Containing Conjugate Trienoic Acids into Their Molecular Species by HPLC in the Reversed-phase and Silver Ion Mode (Reversed-phase 및 $Ag^{+}$-HPLC에 의한 Conjugate Trienoic Acid 함유(含有) Triacylglycerol 분자종(分子種)의 상호분리(相互分離))

  • Kim, Seong-Jin;Woo, Hyo-Kyeng;Joh, Yong-Goe
    • Journal of the Korean Applied Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.197-213
    • /
    • 2001
  • Conjugate trienoic acids (CTA) occurred in triacylglycerols (TGs) of the seed oils of Trichosanthes kirilowii, Momordica charantia and Aleurites fordii, and they were easily converted to their methyl esters in a mixture of sodium methoxide-methanol without any structural destruction. The main fatty acids in triacylglycerol (TG) fraction of the seed oils of Trichosanthes kirilowii are $C_{18:2{\omega}6}$ (32.2 mol %), $C_{18:3{\;}9c.11t,13c}$ (38.0 mol %) and $C_{18:1{\omega}9}$ (11.8 mol %), followed with $C_{16:0}$ (4.8 mol %) and $C_{18:0}$ (3.1 mol %). The TG fraction was resolved into 20 TG molecular species according to the partition number (PN) by reversed-phase (RP)-HPLC. The main TG species were $DT_{c2}$, $MDT_{c}$ and $D_{2}T_{c}$, of which amounts reached 63 mol % of total TG molecular species. The TG sample was fractionated into 11 fractions according to the number of double bond in the molecule by $Ag^{+}-HPLC$ and the species of $DT_{c2}$, $MDT_{c}$ and $D_{2}T_{c}$ were also eluted as main components. The TG species containing CTA showed unusual behaviours in the order of elution by HPLC ; first, TG moleular species of $DT_{c2}$ (D; dienoic acid, $T_{c}$; punicic acid, $T_{ci}$; ${\alpha}-eleostearic$ acid, M ; monoenoic acid, $S_{t}$; stearic acid) was eluted earlier than $Mt_{c2}$, although they have the same PN number of 40, and, secondly, the species of $DT_{ci2}$ with eight double bonds was eluted earlier than that of $D_2T_{ci}$ with seven double bonds. Intact TG of the seed oils of Momordica charantia contained mainly fatty acids such as $C_{18:3{\omega}9c,11t,13t}$ (57.7 mol %), $C_{18:1{\omega}9}$ (17.4 mol %), $C_{18:0}$ (12.3 mol %) and $C_{18:2{\omega}6}$ (10.6 mol %), and was classified into 13 fractions by RP-HPLC. The main TG species were as follows ; $MT_{ci2}$ [$(C_{18:1{\omega}9})(C_{18:3\;9c,11t,13t})_{2}$, 39.1 mol %] and $S_{t}T_{ci2}$ [$(C_{18:0})(C_{18:3\;9c,11t,13t})_2$, 33.9 mol %] comprising about 73 mol % of total TG species, accompanied by $DT_{ci2}$ [$(C_{18:2{\omega}6})(C_{18:3\;9c,11t,13t})_{2}$, 7.3 mol %], $D_{2}T_{ci}$ [$ (C_{18:2{\omega}6})_{2}(C_{18:3\;9c,11t,13t})$, 3.6 mol %] and $MDT_{ci}$ [$(C_{18:1{\omega}9})(C_{18:2{\omega}6})(C_{18:3\;9c,11t,13t})$, 3.5 mol %]. Simple TG species of $T_{ci3}$ [$(C_{18:3\;9c,11t,13t})_3]$ was present in a small amount of 1.4 mol %, but other simple TG species were not detected. The TG was also resolved into 11 fractions according to the number of double bond by $Ag^{+}-HPLC$, and the species were mainly occupied by $MT_{ci2}$ [$(C_{18:1{\omega}9})(C_{18:3\;9c,11t,13t})_{2}$, 39.4 mol %] and $S_tT-{ci2}$ [$(C_{18:0})(C_{18:3\;9c,11t,13t})_{2}$, 35.4 mol %] $DT_{ci2}$ species with eight double bonds was also developed faster than $D_2T_{ci}$ one with seven double bonds as indicated in the analysis of TG of the seed oils of T. kirilowii, and $MT_{ci2}$ species with cis, trans, trans-configurated double bond was eluted earlier than $MT_{c2}$ species with cis, trans, cis-configurated double bond. The main components of fatty acid in total TG fraction isolated from the seed oils of of Aleurites fordii were in the following order ; $C_{18:3\;9c,11t,13t}$ (81.2 mol %)> $C_{18:2{\omega}6}$ (8.5 mol %)> $C_{18:1{\omega}9}$ (5.4 mol %)$. With resolution of the TG by RP-HPLC, eight fractions such as $T_{ci3}$, $Dt_{ci2}$, $D_{2}T_{ci}$, $MT_{ci2}$, $PT_{ci2}$ (P; palmitic acid), $PMT_{ci}$, $PDT_{ci}$ and $S_{t}T_{ci2}$ ($S_{t}$; stearic acid) were isolated, respectively. TG species of $T_{ci3}$ [$(C_{18:3\;9c,11t,13t})_{3}$, 54.2 mol %], $DT_{ci2}$ [$(C_{18:2{\omega}6})(C_{18:3\;9c,11t,13t})_{2}$, 15.0 mol %] and $MT_{ci2}$ [$(C_{18:1{\omega}9})(C_{18:3 9c,11t,13t})_{2}$, 14.8 mol %] were present as main species.

Understanding User Motivations and Behavioral Process in Creating Video UGC: Focus on Theory of Implementation Intentions (Video UGC 제작 동기와 행위 과정에 관한 이해: 구현의도이론 (Theory of Implementation Intentions)의 적용을 중심으로)

  • Kim, Hyung-Jin;Song, Se-Min;Lee, Ho-Geun
    • Asia pacific journal of information systems
    • /
    • v.19 no.4
    • /
    • pp.125-148
    • /
    • 2009
  • UGC(User Generated Contents) is emerging as the center of e-business in the web 2.0 era. The trend reflects changing roles of users in production and consumption of contents on websites and helps us to understand new strategies of websites such as web portals and social network websites. Nowadays, we consume contents created by other non-professional users for both utilitarian (e.g., knowledge) and hedonic values (e.g., fun). Also, contents produced by ourselves (e.g., photo, video) are posted on websites so that our friends, family, and even the public can consume those contents. This means that non-professionals, who used to be passive audience in the past, are now creating contents and share their UGCs with others in the Web. Accessible media, tools, and applications have also reduced difficulty and complexity in the process of creating contents. Realizing that users create plenty of materials which are very interesting to other people, media companies (i.e., web portals and social networking websites) are adjusting their strategies and business models accordingly. Increased demand of UGC may lead to website visits which are the source of benefits from advertising. Therefore, they put more efforts into making their websites open platforms where UGCs can be created and shared among users without technical and methodological difficulties. Many websites have increasingly adopted new technologies such as RSS and openAPI. Some have even changed the structure of web pages so that UGC can be seen several times to more visitors. This mainstream of UGCs on websites indicates that acquiring more UGCs and supporting participating users have become important things to media companies. Although those companies need to understand why general users have shown increasing interest in creating and posting contents and what is important to them in the process of productions, few research results exist in this area to address these issues. Also, behavioral process in creating video UGCs has not been explored enough for the public to fully understand it. With a solid theoretical background (i.e., theory of implementation intentions), parts of our proposed research model mirror the process of user behaviors in creating video contents, which consist of intention to upload, intention to edit, edit, and upload. In addition, in order to explain how those behavioral intentions are developed, we investigated influences of antecedents from three motivational perspectives (i.e., intrinsic, editing software-oriented, and website's network effect-oriented). First, from the intrinsic motivation perspective, we studied the roles of self-expression, enjoyment, and social attention in forming intention to edit with preferred editing software or in forming intention to upload video contents to preferred websites. Second, we explored the roles of editing software for non-professionals to edit video contents, in terms of how it makes production process easier and how it is useful in the process. Finally, from the website characteristic-oriented perspective, we investigated the role of a website's network externality as an antecedent of users' intention to upload to preferred websites. The rationale is that posting UGCs on websites are basically social-oriented behaviors; thus, users prefer a website with the high level of network externality for contents uploading. This study adopted a longitudinal research design; we emailed recipients twice with different questionnaires. Guided by invitation email including a link to web survey page, respondents answered most of questions except edit and upload at the first survey. They were asked to provide information about UGC editing software they mainly used and preferred website to upload edited contents, and then asked to answer related questions. For example, before answering questions regarding network externality, they individually had to declare the name of the website to which they would be willing to upload. At the end of the first survey, we asked if they agreed to participate in the corresponding survey in a month. During twenty days, 333 complete responses were gathered in the first survey. One month later, we emailed those recipients to ask for participation in the second survey. 185 of the 333 recipients (about 56 percentages) answered in the second survey. Personalized questionnaires were provided for them to remind the names of editing software and website that they reported in the first survey. They answered the degree of editing with the software and the degree of uploading video contents to the website for the past one month. To all recipients of the two surveys, exchange tickets for books (about 5,000~10,000 Korean Won) were provided according to the frequency of participations. PLS analysis shows that user behaviors in creating video contents are well explained by the theory of implementation intentions. In fact, intention to upload significantly influences intention to edit in the process of accomplishing the goal behavior, upload. These relationships show the behavioral process that has been unclear in users' creating video contents for uploading and also highlight important roles of editing in the process. Regarding the intrinsic motivations, the results illustrated that users are likely to edit their own video contents in order to express their own intrinsic traits such as thoughts and feelings. Also, their intention to upload contents in preferred website is formed because they want to attract much attention from others through contents reflecting themselves. This result well corresponds to the roles of the website characteristic, namely, network externality. Based on the PLS results, the network effect of a website has significant influence on users' intention to upload to the preferred website. This indicates that users with social attention motivations are likely to upload their video UGCs to a website whose network size is big enough to realize their motivations easily. Finally, regarding editing software characteristic-oriented motivations, making exclusively-provided editing software more user-friendly (i.e., easy of use, usefulness) plays an important role in leading to users' intention to edit. Our research contributes to both academic scholars and professionals. For researchers, our results show that the theory of implementation intentions is well applied to the video UGC context and very useful to explain the relationship between implementation intentions and goal behaviors. With the theory, this study theoretically and empirically confirmed that editing is a different and important behavior from uploading behavior, and we tested the behavioral process of ordinary users in creating video UGCs, focusing on significant motivational factors in each step. In addition, parts of our research model are also rooted in the solid theoretical background such as the technology acceptance model and the theory of network externality to explain the effects of UGC-related motivations. For practitioners, our results suggest that media companies need to restructure their websites so that users' needs for social interaction through UGC (e.g., self-expression, social attention) are well met. Also, we emphasize strategic importance of the network size of websites in leading non-professionals to upload video contents to the websites. Those websites need to find a way to utilize the network effects for acquiring more UGCs. Finally, we suggest that some ways to improve editing software be considered as a way to increase edit behavior which is a very important process leading to UGC uploading.

Effectiveness Assessment on Jaw-Tracking in Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy for Esophageal Cancer (식도암 세기조절방사선치료와 용적세기조절회전치료에 대한 Jaw-Tracking의 유용성 평가)

  • Oh, Hyeon Taek;Yoo, Soon Mi;Jeon, Soo Dong;Kim, Min Su;Song, Heung Kwon;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.33-41
    • /
    • 2019
  • Purpose : To evaluate the effectiveness of Jaw-tracking(JT) technique in Intensity-modulated radiation therapy(IMRT) and Volumetric-modulated arc therapy(VMAT) for radiation therapy of esophageal cancer by analyzing volume dose of perimetrical normal organs along with the low-dose volume regions. Materials and Method: A total of 27 patients were selected who received radiation therapy for esophageal cancer with using $VitalBeam^{TM}$(Varian Medical System, U.S.A) in our hospital. Using Eclipse system(Ver. 13.6 Varian, U.S.A), radiation treatment planning was set up with Jaw-tracking technique(JT) and Non-Jaw-tracking technique(NJT), and was conducted for the patients with T-shaped Planning target volume(PTV), including Supraclavicular lymph nodes(SCL). PTV was classified into whether celiac area was included or not to identify the influence on the radiation field. To compare the treatment plans, Organ at risk(OAR) was defined to bilateral lung, heart, and spinal cord and evaluated for Conformity index(CI) and Homogeneity index(HI). Portal dosimetry was performed to verify a clinical application using Electronic portal imaging device(EPID) and Gamma analysis was performed with establishing thresholds of radiation field as a parameter, with various range of 0 %, 5 %, and 10 %. Results: All treatment plans were established on gamma pass rates of 95 % with 3 mm/3 % criteria. For a threshold of 10 %, both JT and NJT passed with rate of more than 95 % and both gamma passing rate decreased more than 1 % in IMRT as the low dose threshold decreased to 5 % and 0 %. For the case of JT in IMRT on PTV without celiac area, $V_5$ and $V_{10}$ of both lung showed a decrease by respectively 8.5 % and 5.3 % in average and up to 14.7 %. A $D_{mean}$ decreased by $72.3{\pm}51cGy$, while there was an increase in radiation dose reduction in PTV including celiac area. A $D_{mean}$ of heart decreased by $68.9{\pm}38.5cGy$ and that of spinal cord decreased by $39.7{\pm}30cGy$. For the case of JT in VMAT, $V_5$ decreased by 2.5 % in average in lungs, and also a little amount in heart and spinal cord. Radiation dose reduction of JT showed an increase when PTV includes celiac area in VMAT. Conclusion: In the radiation treatment planning for esophageal cancer, IMRT showed a significant decrease in $V_5$, and $V_{10}$ of both lungs when applying JT, and dose reduction was greater when the irradiated area in low-dose field is larger. Therefore, IMRT is more advantageous in applying JT than VMAT for radiation therapy of esophageal cancer and can protect the normal organs from MLC leakage and transmitted doses in low-dose field.

Shopping Value, Shopping Goal and WOM - Focused on Electronic-goods Buyers (쇼핑 가치 추구 성향에 따른 쇼핑 목표와 공유 의도 차이에 관한 연구 - 전자제품 구매고객을 중심으로)

  • Park, Kyoung-Won;Park, Ju-Young
    • Journal of Global Scholars of Marketing Science
    • /
    • v.19 no.2
    • /
    • pp.68-79
    • /
    • 2009
  • The interplay between hedonic and utilitarian attributes has assumed special significance in recent years; it has been proposed that consumption offerings should be viewed as experiences that stimulate both cognitions and feelings rather than as mere products or services. This research builds on previous work on hedonic versus utilitarian benefits, regulatory focus theory, customer satisfaction to address two question: (1) Is the shopping goal at the point of purchase different from the shopping value? and (2) Is the customer loyalty after the use different from the shopping value and shopping goal? We surveyed 345 peoples those who have bought the electronic-goods within 6 months. This research dealt with the shopping value which is consisted of 2 types, hedonic and utilitarian. Those who pursue the hedonic shopping value may prefer the pleasure of purchasing experience to the product itself. They tend to prefer atmosphere, arousal of the shopping experience. Consistent with previous research, we use the term "hedonic" to refer to their aesthetic, experiential and enjoyment-related value. On the contrary, Those who pursue the utilitarian shopping value may prefer the reasonable buying. It may be more functional. Consistent with previous research, we use the term "utilitarian" to refer to the functional, instrumental, and practical value of consumption offerings. Holbrook(1999) notes that consumer value is an experience that results from the consumption of such benefits. In the context of cell phones for example, the phone's battery life and sound volume are utilitarian benefits, whereas aesthetic appeal from its shape and color are hedonic benefits. Likewise, in the case of a car, fuel economics and safety are utilitarian benefits whereas the sunroof and the luxurious interior are hedonic benefits. The shopping goals are consisted of the promotion focus goal and the prevention focus goal, based on the self-regulatory focus theory. The promotion focus is characterized into focusing ideal self because they are oriented to wishes and vision. The promotion focused individuals are tend to be more risk taking. They are more sensitive to hope and achievement. On the contrary, the prevention focused individuals are characterized into focusing the responsibilities because they are oriented to safety. The prevention focused individuals are tend to be more risk avoiding. We wanted to test the relation among the shopping value, shopping goal and customer loyalty. Customers show the positive or negative feelings comparing with the expectation level which customers have at the point of the purchase. If the result were bigger than the expectation, customers may feel positive feeling such as delight or satisfaction and they would want to share their feelings with other people. And they want to buy those products again in the future time. There is converging evidence that the types of goals consumers expect to be fulfilled by the utilitarian dimension of a product are different from those they seek from the hedonic dimension (Chernev 2004). Specifically, whereas consumers expect the fulfillment of product prevention goals on the utilitarian dimension, they expect the fulfillment of promotion goals on the hedonic dimension (Chernev 2004; Chitturi, Raghunathan, and Majahan 2007; Higgins 1997, 2001) According to the regulatory focus theory, prevention goals are those that ought to be met. Fulfillment of prevention goals in the context of product consumption eliminates or significantly reduces the probability of a painful experience, thus making consumers experience emotions that result from fulfillment of prevention goals such as confidence and securities. On the contrary, fulfillment of promotion goals are those that a person aspires to meet, such as "looking cool" or "being sophisticated." Fulfillment of promotion goals in the context of product consumption significantly increases the probability of a pleasurable experience, thus enabling consumers to experience emotions that result from the fulfillment of promotion goals. The proposed conceptual framework captures that the relationships among hedonic versus utilitarian shopping values and promotion versus prevention shopping goals respectively. An analysis of the consequence of the fulfillment and frustration of utilitarian and hedonic value is theoretically worthwhile. It is also substantively relevant because it helps predict post-consumption behavior such as the promotion versus prevention shopping goals orientation. Because our primary goal is to understand how the post consumption feelings influence the variable customer loyalty: word of mouth (Jacoby and Chestnut 1978). This research result is that the utilitarian shopping value gives the positive influence to both of the promotion and prevention goal. However the influence to the prevention goal is stronger. On the contrary, hedonic shopping value gives influence to the promotion focus goal only. Additionally, both of the promotion and prevention goal show the positive relation with customer loyalty. However, the positive relation with promotion goal and customer loyalty is much stronger. The promotion focus goal gives the influence to the customer loyalty. On the contrary, the prevention focus goal relates at the low level of relation with customer loyalty than that of the promotion goal. It could be explained that it is apt to get framed the compliment of people into 'gain-non gain' situation. As the result, for those who have the promotion focus are motivated to deliver their own feeling to other people eagerly. Conversely the prevention focused individual are more sensitive to the 'loss-non loss' situation. The research result is consistent with pre-existent researches. There is a conceptual parallel between necessities-needs-utilitarian benefits and luxuries-wants-hedonic benefits (Chernev 2004; Chitturi, Raghunathan and Majaha 2007; Higginns 1997; Kivetz and Simonson 2002b). In addition, Maslow's hierarchy of needs and the precedence principle contends luxuries-wants-hedonic benefits higher than necessities-needs-utilitarian benefits. Chitturi, Raghunathan and Majaha (2007) show that consumers are focused more on the utilitarian benefits than on the hedonic benefits of a product until their minimum expectation of fulfilling prevention goals are met. Furthermore, a utilitarian benefit is a promise of a certain level of functionality by the manufacturer or the retailer. When the promise is not fulfilled, customers blame the retailer and/or the manufacturer. When negative feelings are attributable to an entity, customers feel angry. However in the case of hedonic benefit, the customer, not the manufacturer, determines at the time of purchase whether the product is stylish and attractive. Under such circumstances, customers are more likely to blame themselves than the manufacturer if their friends do not find the product stylish and attractive. Therefore, not meeting minimum utilitarian expectations of functionality generates a much more intense negative feelings, such as anger than a less intense feeling such as disappointment or dissatisfactions. The additional multi group analysis of this research shows the same result. Those who are unsatisfactory customers who have the prevention focused goal shows higher relation with WOM, comparing with satisfactory customers. The research findings in this article could have significant implication for the personal selling fields to increase the effectiveness and the efficiency of the sales such that they can develop the sales presentation strategy for the customers. For those who are the hedonic customers may be apt to show more interest to the promotion goal. Therefore it may work to strengthen the design, style or new technology of the products to the hedonic customers. On the contrary for the utilitarian customers, it may work to strengthen the price competitiveness. On the basis of the result from our studies, we demonstrated a correspondence among hedonic versus utilitarian and promotion versus prevention goal, WOM. Similarly, we also found evidence of the moderator effects of satisfaction after use, between the prevention goal and WOM. Even though the prevention goal has the low level of relation to WOM, those who are not satisfied show higher relation to WOM. The relation between the prevention goal and WOM is significantly different according to the satisfaction versus unsatisfaction. In addition, improving the promotion emotions of cheerfulness and excitement and the prevention emotion of confidence and security will further improve customer loyalty. A related potential further research could be to examine whether hedonic versus utilitarian, promotion versus prevention goals improve customer loyalty for services as well. Under the budget and time constraints, designers and managers are often compelling to choose among various attributes. If there is no budget or time constraints, perhaps the best solution is to maximize both hedonic and utilitarian dimension of benefits. However, they have to make trad-off process between various attributes. For the designers and managers have to keep in mind that without hedonic benefit satisfaction of the product it may hard to lead the customers to the customer loyalty.

  • PDF

The Process of Establishing a Japanese-style Garden and Embodying Identity in Modern Japan (일본 근대 시기 일본풍 정원의 확립과정과 정체성 구현)

  • An, Joon-Young;Jun, Da-Seul
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.41 no.3
    • /
    • pp.59-66
    • /
    • 2023
  • This study attempts to examine the process of establishing a Japanese-style garden in the modern period through the perspectives of garden designers, spatial composition, spatial components, and materials used in their works, and to use it as data for embodying the identity of Korean garden. The results are as follows: First, by incorporating elements associated with Koreanness into the modern garden culture, there are differences in location, presence, and subjectivity when compared to Japan. This reflects Japan's relatively seamless cultural continuity compared to Korea's cultural disconnection during the modern period. Second, prior to the modern period, Japan's garden culture spread and continued to develop throughout the country without significant interruptions. However, during the modern period, the Meiji government promoted the policy of 'civilization and enlightenment (Bunmei-kaika, 文明開化)' and introduced advanced European and American civilizations, leading to the popularity of Western-style architectural techniques. Unfortunately, the rapid introduction of Western culture caused the traditional Japanese culture to be overshadowed. In 1879, British architect Josiah Condor guided Japanese architects and introduced atelier and traditional designs of Japanese gardens into the design. The garden style of Ogawa Jihei VII, a garden designer in Kyoto during the Meiji and Taisho periods, was accepted by influential political and business leaders who sought to preserve Japan's traditional culture. And a protection system of garden was established through the preparation of various laws and regulations. Third, as a comprehensive analysis of Japanese modern gardens, the examination of garden designers, Japanese components, materials, elements, and the Japanese-style showed that Yamagata Aritomo, Ogawa Jihei VII, and Mirei Shigemori were representative garden designers who preserved the Japanese-style in their gardens. They introduced features such as the creation of a Daejicheon(大池泉) garden, which involves a large pond on a spacious land, as well as the naturalistic borrowed scenery method and water flow. Key components of Japanese-style gardens include the use of turf, winding garden paths, and the variation of plant species. Fourth, an analysis of the Japanese-style elements in the target sites revealed that the use of flowing water had the highest occurrence at 47.06% among the individual elements of spatial composition. Daejicheon and naturalistic borrowed scenery were also shown. The use of turf and winding paths were at 65.88% and 78.82%, respectively. The alteration of tree species was relatively less common at 28.24% compared to the application of turf or winding paths. Fifth, it is essential to discover more gardens from the modern period and meticulously document the creators or owners of the gardens, the spatial composition, spatial components, and materials used. This information will be invaluable in uncovering the identity of our own gardens. This study was conducted based on the analysis of the process of establishing the Japanese-style during Japan's modern period, utilizing examples of garden designers and gardens. While this study has limitations, such as the absence of in-depth research and more case studies or specific techniques, it sets the stage for future exploration.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Clinical Analysis of Infective Endocarditis (감염성 심내막염의 임상적 고찰)

  • Kim, Hyuck;Kim, Young-Hak;Chung, Won-Sang;Shin, Kyung-Wook;Kim, Ji-Hoon
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.619-626
    • /
    • 2010
  • Background: The indications and the optimal time of surgery of infective endocarditis are controversial. We report the surgical results of our hospital during the last 10 years with literature review. Material and Method: Between January 2000 and December 2009, we enrolled 23 infective endocarditis patients who underwent surgery, and analyzed retrospectively. In the preoperative blood culture, 8 cases (34.8%) were positive. The average preoperative antibiotics treatment period was $20.78{\pm}16.00$ days. There were 12 (52.2%) urgent operations. The average follow up period was $49.26{\pm}33.21$ months. Result: 20 mechanical valve replacements were performed, 9 in aortic position, 8 in mitral position and 3 in the both positions. The other procedures were one mitral valvuloplasty, one infected myxoma extirpation, and one infected pacemaker lead removal with debridement. The average period of postoperative intravenous antibiotic treatment was $24.39{\pm}15.98$ days. There were 5 complications, including 2 cases of postoperative bleeding, one postcardiotomy syndrome, one cerebral ischemia, and a low cardiac output syndrome. There were statistically significant postoperative improvement in NYHA class, left ventricle end diastolic/end systolic volume, and left atrium size (p-value < 0.05). Conclusion: We could obtain the satisfactory results without any moftalities by using sufficient preoperative antibiotics in hemodynamically stable patients, and by prompt surgery in unstable patients.