• 제목/요약/키워드: wiring short

검색결과 44건 처리시간 0.023초

저압용 전열수구에서 방전 신호의 발생과 검출에 관한 연구 (Studies on Generation and Detection of Discharge Signals in a Low-voltage Outlet)

  • 길경석;송재용;서황동;문승보;조영진;황돈하
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권11호
    • /
    • pp.498-502
    • /
    • 2005
  • The objectives of this paper are to provide information on the characteristics of the discharge signals in a low-voltage indoor outlet. Most of electrical fires are caused by short circuits, overheating of wires, deterioration and incomplete connection of wiring devices. The last two cases are predictable before the occurrence of fire because of its slow progress. We have simulated the discharge signals caused by the deterioration and incomplete connection of wiring devices using aged outlets. From the experimental data, we could characterize the frequency spectrums of the discharge signals depending on the cases. The higher frequency components of the signal are attenuated by the capacitance and inductance of power lines as the measuring point is getting away from the discharges. Main frequency components of the discharge signal are existent at 600kHz - 1.5MHz in incomplete connections and at 210H7z - 8MHz in deteriorations of the outlet.

전차선로 순환전류 발생원인과 대책에 관한 연구 (A Study on Causes and Measures Against Occurrence of Circulating Current in catenary)

  • 한학수;민경윤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.816-823
    • /
    • 2007
  • Electric car tract plays the role of supply high electric power to the electric car from the substation by using Pantograph of the electric car. It is always exposed to the external atmosphere, which results in quite substantial fluctuations in current and voltage during operation of electric car. This generates possibility of occurrence of accident at all times. Since range of wiring metallic globe installed on the catenary cannot achieve complete electrical contact, accidents are occurring due to circulating current caused by arc caused by incomplete contact due to occurrence of hairline fracture of Pantograph due to pressure or vibration of wiring. Furthermore, rapid increase in the operational current due to increase in the operational frequency of the electric car is causing erosion and short circuit of the metallic globe at the contact points. This study on arc is generated as current transmitted out of the substation courses through power line or wiring metallic globe other than the main circuit as the current is being collected at the electric car through feeder and feeder divergence device. Accordingly, since heat generated by the arc becomes the cause for generation of circulating current due to melting of metal or softening of metal due to increase in temperature accompanying increase in contact resistance, this research shall describe causes and measures against occurrence of circulation current.

  • PDF

다중 분산부하 전압강하산정 프로그램 연구 (A Study of the Voltage drops computation program on multi-distributed random loads)

  • 강차녕;권세혁;조성필
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.37-42
    • /
    • 2006
  • 전선에서 전압강하는 열 손실을 의미한다. 이 열은 절연체의 특성을 변화시켜 절연성능을 저하시키게 되고 나아가 누전, 감전, 정전 및 화재 등의 사고를 일으키는 원인이 되기도 한다. 그러므로 전압강하에 대한 최적화 설계는 전기설비의 안전성과 경제성을 보장하는 중요한 요소가 되고 있다. 이에 저압의 전기설비인 가로등, 빌딩, 지하철역사 등 공공의 안전확보가 요구되는 다중 분산부하계통에서의 전압강하가 전기배선에 미치는 영향을 분석하고, 안전성 및 경제성 확보를 위한 전압강하산정 프로그램 및 최적화 방안을 연구 제시하고자 한다.

  • PDF

자동차 엔진룸 관련 전기 배선의 단락 및 열에 의한 절연피복 용융에 대한 화재사례 연구 (Study of Fire Examples for Electrical Wire Short and Insulated Coating Melting by Heating Including Automotive Engine Room)

  • 이일권;김영규;염광옥
    • 한국가스학회지
    • /
    • 제17권6호
    • /
    • pp.15-19
    • /
    • 2013
  • 이 논문은 자동차 엔진룸에서 전기적인 접촉불량에 의한 단락현상과 엔진의 뜨거운 열에 의해 가연성 물질과 접촉하여 화재가 발생된 원인을 분석하고 연구하는 것이다. 첫째, 배터리에서 시동모터로 연결되어 있는 배터리 전원선이 자동변속기 상단에 배선을 고정시켜 주는 브래킷(Bracket) 볼트 이완으로 차체와의 단락 현상에 의해 화재가 발생된 것을 확인하였다. 둘째, 배터리에서 시동모터까지 가는 배선에 감은 절연테이프가 녹아 단락현상에 의해 화재를 일으킨 것을 확인하였다. 셋째, 냉각 팬 배선이 이완되어 과열된 엔진의 열에 의해 배선이 융착되어 화재가 발생된 것을 확인하였다 따라서, 엔진에 관련된 시스템의 화재는 엔진 및 각 시스템의 손상으로 자동차 탑승객을 위험에 처하게 하며, 화재 후 자동차는 재사용이 어렵게 되므로 시스템의 철저한 관리와 세심한 주의가 요구되어진다.

과부하 및 물리적 손상(반단선)에 의한 전선의 열적특성 해석 (Analysis for the Thermal Properties of the Electrical Wire according to Overload and Disconnection)

  • 김성철;김두현
    • 한국안전학회지
    • /
    • 제22권4호
    • /
    • pp.26-31
    • /
    • 2007
  • According to the statistical analysis on the electrical fire of 2005 years, most of electrical fire is generated from short circuit(4,985 cases), overcurrent(755 cases) leakage current(391 cases), poor contact(378 cases), disconnection(36 cases) on the electrical wiring device. The researches for the fire hazard about normal electric wiring have already been progressing in the advanced country such as USA and Japan, but Comparative study of the disconnection has not been conducted. Therefore, in this paper, we have simulated the thermal analysis for electrical wire according to deteriorating time in a normal state and disconnection with electrical wire using the electrical-thermal finite element method(Flux 3D). This paper acquire basis data of electricity fire signal by disconnection and wish to help for electrical fire cause diagnosis business.

전기철도 전차선과 판토그래프 이선에 대한 연구 (A Study on De-wiring at Electric Railway Trolley wire and Pantograph)

  • 신승철;김재철;한성호;이수길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.319-320
    • /
    • 2006
  • At this study, one of the electrical problems, arc characteristics according to loss of contact between a pantograph and a catenary, was analyzed. A characteristic of arc current is disappeared in a short period of time. Nevertheless, it has large current same as a surge, so that it has EMI/EMC problems. In the case of the electrical railway system, there is oscillation and de-wiring. The are current is generated by these problems. The result of this study can be used as a facility design to prevent a surge and needs to prove through actual field data in the main circuit of an electric train for a precise analysis about effect of are.

  • PDF

전계-열계 유한요소해석을 이용한 저압 배선선로의 과부하 및 단락사고 발생시 전선의 온도해석에 관한 연구 (A Study on the Temperature Analysis for Cable in Overload and Short of Low Voltage Wiring using Electro-Thermal FEA)

  • 오홍석
    • 한국산업융합학회 논문집
    • /
    • 제7권1호
    • /
    • pp.91-96
    • /
    • 2004
  • Overloading of electrical equipment results in excessive currents. As the heat developed in the cables is proportional to square of the current, they get overheated. The insulation on cables is generally made of materials which are damaged easily by excessive temperature. They may therefore lose their insulating properties and lead to short circuits. Since many insulating materials are combustible, they may even catch fire if the temperature rises to their ignition temperature. In this paper, we have simulated the thermal analysis for cable according to the value of current in a overload and a short with the cable of the L's company product(600 V, VV : Four Core) using the electro-thermal finite element method(Flux2D).

  • PDF

열화된 저압용 콘센트에서 방전신호의 발생과 검출 (Generation and Detection of Discharge Signals in Deteriorated)

  • 송재용;서황동;문승보;길경석;조영진
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.200-203
    • /
    • 2005
  • Most of electrical fires are caused by short circuits, overheating of wires, deterioration and incomplete connection of wiring devices. The last two cases are predictable before the occurrence of fire because of its slow progress. In this paper, we have simulated the discharge signals caused by the deterioration and incomplete connection of wiring devices using an aged concent to provide information on the characteristics of discharge signals. From the experimental data, we could characterize the frequency spectrums of the discharge signals depending on the cases. The higher frequency components of the signal are attenuated by the capacitance and inductance of power lines as the measuring point is getting away from the discharges. Main frequency components of the discharge signal are existent at 600 kHz - 1.5 MHz in incomplete connections and at 210 kHz - 8 Mhz in deteriorations of the concent.

  • PDF

승용자동차 전자제어 에어컨 장치의 다이오드, 써모센서와 배선단락에 대한 고장사례 고찰 (A Study for Faliure Examples Involved Diode, Thermo Sensor and Wiring Short of Electronic Control A/C System in a Vehicle)

  • 이일권;국창호;함성훈;이정호;문학훈;유창배;황한섭;임춘무;정동화;나윤환
    • 한국가스학회지
    • /
    • 제21권5호
    • /
    • pp.83-88
    • /
    • 2017
  • 이 논문은 자동차의 전자제어 에어컨에서 발생하는 고장사례에 대한 논문이다. 첫 번째 사례에서, 원인은 에어컨 릴레이 내부에 서지 전압 역류 방지용으로 사용된 다이오드가 에어컨이 OFF 되었을 때 다이오드의 단락으로 인해, 서지 전압을 흡수하지 못해 퓨즈가 반복적으로 끊어진 것을 확인하였다. 두 번째 사례에서, 원인은 핀 써모센서 내부의 단선으로 인해 에어컨을 제어하지 못함으로써 이베퍼레이터의 동결현상이 발생한 것을 확인하였다. 세 번째 사례에서, 원인은 운전석 앞쪽의 크래쉬 패드 하단에 있는 와이어링의 에어컨 핀센서 핀과 연결되는 배선이 차체와의 간섭으로 인해, 피복이 벗져져 단락(short)현상에 의해 에어컨 스위치와 핀센서가 소손되어 에어컨이 작동하지 않는 것을 확인하였다. 따라서, 이러한 고장 현상을 철저하게 확인하고 개선하여 최적의 시스템을 유지할 수 있도록 하여야 한다.