• Title/Summary/Keyword: wiring

Search Result 518, Processing Time 0.027 seconds

AS-Interface Protocol Utilization for Smart Ships (스마트선박을 위한 AS-Interface 프로토콜 활용 방안)

  • Ri Gon Kim;Young Hwan Cho;Ki Hwan Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.6
    • /
    • pp.482-490
    • /
    • 2023
  • With the advent of the Fourth Industrial Revolution, many companies are developing Smart Ships to enable autonomous navigation, unmanned operation, and cost-effective shipping. In order to facilitate the operation of these Smart Ships, significant emphasis is being placed on improving external communication capabilities and developing autonomous navigation systems. Moreover, unmanned ship operation necessitates replacing of all visually observed conditions with sensors, leading to an inevitable increase in the number of sensors and actuators compared to traditional methods. However, in South Korea, the communication network for sensors and actuators primarily relies on the conventional 1:1 hardwired wiring, with the use of higher-level communication networks when necessary. Therefore, in this paper, we introduce the AS-Interface protocol, which is used for monitoring and controlling sensors and actuators, with the expectation that it will greatly contribute to the development of future Smart Ships by reducing production time, costs, and maintenance duration.

Industrial Deep Learning-based Mobility Platform Research for Anomaly Wiring Detection (산업용 딥러닝 기반 배선 이상 검출을 위한 모빌리티 플랫폼 연구)

  • Hyeon-Woo No;Ji-Soo Kim;Min-Uk Oh;Sang-Bae Park
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.11a
    • /
    • pp.957-958
    • /
    • 2023
  • 본 연구에서는 공정 내 인체 끼임 사고 및 저출산 고령화 시대 등의 문제들로 인한 인력 감소 문제들을 해결하기 위하여 인공지능 기반의 모빌리티 플랫폼을 개발하였다. 본 플랫폼은 yolo-v4 기반으로 로봇이 공정 내부를 이동하면서 공정 내 불량 와이어를 검출하여 공정 유지보수 관리자에게 알려 주고 실시간으로 공정 내부 상황을 무선으로 모니터링할 수 있는 기술을 연구하였다. 또한, 로봇에는 무선 충전 기능을 갖추고 있어 추가적인 공정 내 인체 끼임 사고 등을 예방할 수 있도록 하였다. 본 연구 결과에서는 불량 와이어 검출 시, 평균 92.1%의 정확도를 보였으며, 공정 제품에 대한 양품, 불량품의 검출은 평균 98%의 정확도를 보였다. 또한, 실시간 무선 영상 모니터링는 24fps로 전송되어 공정 내부를 살피는 것에 유의미한 결과를 보였다.

The Effect of Complex Korean Medical Treatment for Tibia, Fibula and Patellar Fractures in Patient with Sequelae of Poliomyelitis: A Case Report (경비골, 슬개골 동시 골절된 소아마비 후유증 환자에 대한 한방복합치료 1례)

  • Chae-Young Kim;Ji-Su Choi;Hee-Duk An
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.34 no.2
    • /
    • pp.173-180
    • /
    • 2024
  • Objectives The purpose of this study is to report the effects of Korean medicine treatment on tibia, fibula, and patellar fractures with sequelae of poliomyelitis. Methods A 64-year-old male patient was treated with acupuncture, herbal medicine, cupping, moxibustion, and exercise treatment for 59 days after open reduction and internal fixation and tension band wiring surgery. The effects were evaluated using a visual analog scale (VAS), manual muscle testing (MMT), range of motion (ROM), Western Ontario and McMaster Universities (WOMAC), and EuroQol-5 dimension (EQ-5D) index. Results After treatment, VAS decreased from 7 to 2. MMT, ROM, WOMAC, EQ-5D and walking ability were improved. Conclusions This case study suggests that Korean medicine treatment could be effective for tibia, fibula, patellar fractures in patients with sequelae of poliomyelitis.

Characteristics of Insulation Resistance of Cable according to Temperature Rise and Over-Current for Process of the Melting Furnace (용해로의 공정상 온도상승 및 과전류에 따른 케이블의 절연저항 특성)

  • Suk Bong Ko;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.2
    • /
    • pp.22-27
    • /
    • 2024
  • The purpose of this study is to explore the trend in insulation resistance values according to temperature and overcurrent by conducting an investigation on the actual condition and experiments on the electrical wiring during the melting furnace process. In addition, the Arrhenius equation is used to determine whether temperatures in the furnace operating process can be applied to the actual field. In the investigation of the actual condition, the insulation resistance started to decrease seven years after replacement, even though cables in oil pump A were replaced in 2010. Both the experimental and theoretical values of the insulation resistance obtained using the Arrhenius equation decreased with an increase in temperature. Errors in insulation resistance (MΩ) values between tests and the Arrhenius equation ranged from ±2 to ±10, demonstrating a high similarity. Results revealed that when the insulation resistance cannot be measured in a manufacturing workplace (quarterly analysis), it can be estimated by partially applying the Arrhenius equation.

Risk Priority Analysis for Preventing Electrical Fires in Food Manufacturing Electrical Facilities (식료품제조업 전기설비의 전기화재방지를 위한 위험우선순위 분석)

  • Seung Ku Lee;Doo Hyun Kim;Sung Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.1
    • /
    • pp.16-26
    • /
    • 2024
  • This study aims to introduce a method for risk assessment analysis aimed at preventing electrical fires within the manufacturing industry. Initially, we provided a functional block diagram illustrating the electrical equipment employed in various processes within a food manufacturing company in Chungcheongbuk-do. Subsequently, we categorized the components of each machine outlined in the functional block diagram and determined the priority of failure for each classified component. Upon implementing the model in the frying process of the food manufacturing company, specific components, including MC, motor, mixer heater, electric wiring, and terminal block, exhibit a risk priority number (RPN) of 40 or higher. This identified an electrical issue within the manufacturing process and environment. Consequently, we propose a methodology to identify latent failure modes that could escalate into fires or systemic issues if not promptly addressed. It is essential to note that while the FMEA presented in this study may not immediately impact food manufacturing, its applicability extends to various workplaces.

An Experimental Study on the Ultimate Strength and Deformation Capacity of Composite Beams with Eccentric Web Openings (편심유공합성보의 종국내력 및 변형능력에 관한 실험적 연구)

  • Choi, San Ho;Seo, Seong Yeon
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.595-604
    • /
    • 2000
  • Web openings of large beams provide space for wiring, piping, and duct work to provide for proper drainage, pipes and duct must be slightly sloped with the attendant result that all web openings can not be centered on the centroidal axes of the beams. Test specimens are made for opening-depth to beam-depth ratio of 0.5 and for eccentricities of the opening center line of 10% from middepth of the beam because of the proximity of the opening edge to the flange. In this paper, available test results and theories relating to the strength of composite beams having eccentric rectangular openings are surveyed and experiments were carried out to examine the structural behaviors. In all the tests in this paper good agreement is demonstrated with maximum loads measured in tests, and observed failure modes Furthermore, compared with analytical values and experimental values of interaction diagram between moment and shear capacity were safed as it is scattered with outer part of the analytical values.

  • PDF

Analysis on the Voltage, Current and Temperature Signals for Free and Locked Operation of Three Speed Electric Fan (3단 스피드 선풍기 모터의 정상 및 고정 운전에 대한 전압, 전류 및 온도 신호 분석)

  • Kim, Yoon Bok;Kim, Doo Hyun
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.87-91
    • /
    • 2014
  • This paper is aimed to find electrical fire danger for analyzing the characteristics of temperature, current and voltage signals for motor on electric fan. In order to attain this purpose, detected were the temperature, current and voltage signals on electric wire with free (normal state) and locked (abnormal state) motor. For voltage and current signals, voltage signal is no big difference with normal and abnormal states and current signal is higher in abnormal state (highest 309 mA) than the normal state (highest 203 mA). In the case of Temperature signal, the temperature distribution of the motor as a whole is different. It is difference in the case of the normal state $4^{\circ}C$ and the abnormal state $18^{\circ}C$. In particular, most of the electric wiring to the motor of the fan is attached to the fixture of motor back. Considering at allowable temperature ($60^{\circ}C$) of the electric wire could be accelerated to insulation deterioration. The results of this study will be effectively used in analyzing for electric fire and developing the preventive devices of electric fan.

Study on the Emergency Broadcasting System Using Ultrasonic Waves (초음파를 이용한 비상방송시스템에 관한 연구)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.186-189
    • /
    • 2019
  • NFSC 202 stipulates that if a loudspeaker or wiring on one floor of a building is shorted because of fire, it should not interfere with the fire notification on the other floors. To address this problem, this study proposes an ultrasonic transmitter/receiver consisting of an ADC, HPF, and LPF in an emergency broadcasting system that can operate regardless of the volume level of the amplifier output loudspeaker capacity. After transmitting the transmission frequency at -12 dB (110 kHz), it is received at -18 dB by transmitting -12 dB in case of short circuit depending on the frequency characteristics. Typically, depending on the loudspeaker capacity, it is received from -24 dB to -66 dB. In case of disconnection, it exceeds -66 dB and no data are received. It is also possible to check the track status during fire or general broadcasting. Thus, it was confirmed that the system is suitable for NFSC 202 regulations. Furthermore, as the current system is replaced, the inspection or test criteria should be amended or revised.

The Design and Implementation of a Network-based Stand-alone Motion System

  • Cho, Myoung-Chol;Jeon, Jae-Wook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.865-870
    • /
    • 2003
  • A motion controller has been used variously in industry such as semiconductor manufacture equipment, industrial robot, assembly/conveyor line applications and CNC equipment. There are several types of controller in motion control. One of these is a PC-based motion controller such as PCI or ISA, and another is stand-alone motion controller. The PC bus-based motion controller is popular because of improving bus architectures and GUI (Graphic User Interface) that offer convenience of use to user. There are some problems in this. The PC bus-based solution allows for only one of the form factors, so it has a poor flexibility. The overall system package size is bigger than other motion control system. And also, additional axes of control require additional slot, however the number of slots is limited. Furthermore, unwieldy and many wirings come to connect plants or I/O. The stand-alone motion controller has also this limit of axes of control and wiring problems. To resolve these problems, controller must have capability of operating as stand-alone devices that resides outside the computer and it needs network capability to communicate to each motion device. In this paper, a network-based stand-alone motion system is proposed. This system integrates PC and motion controller into one stand-alone motion system, and uses CAN (Controller Area Network) as network protocol. Single board computer that is type of 3.5" FDD form factor is used to reduce the system size and cost. It works with Windows XP Embedded as operating system. This motion system operates by itself or serves as master motion controller that communicates to slave motion controller. The Slave motion controllers can easily connect to master motion system through CAN-network.

  • PDF

A Placement Prablem with Wire Congestion in LSI Layout CAD (LSI의 Layout CAD에 있어서의 배선 혼잡도를 고려한 배치 문제)

  • Im, In-Chil;Jeong, Jeong-Hwa;Lee, Byeong-Ho
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.3
    • /
    • pp.19-27
    • /
    • 1982
  • Minimization of total routing and number of cuts has been adopted for the placement problem in LSI and printed wire board as the object function, recently. Although it is considered that in the general situation this object function reflects the final goal which is wiring of 100% of layout, it often seems to be insufficient because it does not exhibit partial wire congestion. This paper introduces a new concept called the wire congestion of segestion to get the partial wire congestion and proposes the object function to minimize the wire congestion of segmests. In order to optimize this object function, an effective heuristic algorithm is also suggestsl Experimental results show that this algorithm sustains its efficiency. The experimental consequences point out that if the total routing length is short, maximum wire congestion of segment is small and vice versa. Therefore control parameter, that is, congestion parameter, which mintnizes total length and concurrently reduces maximal wire congestion of segment, is obtained by experiment.

  • PDF