• 제목/요약/키워드: wire length.

검색결과 516건 처리시간 0.023초

스프링형상 와이어소재를 이용한 접합동시 파이프 압출성형공정 개발에 관한 연구 (Development of a Process to Simultaneously Weld and Extrude Pipe Using a Spring Type Wire Material)

  • 구경만;김태현;진인태
    • 소성∙가공
    • /
    • 제24권5호
    • /
    • pp.317-322
    • /
    • 2015
  • A process for the concurrent welding and extruding of pipe was designed for continuous production of fin tubes. Unlike a conventional pipe extrusion, the new process is able to extrude a pipe continuously without limit of length by using spring type wire material. The current paper provides the basic research for welding during the extrusion using a spring type wire material. The object of the current study is to investigate the possibility that the spring type wire material could be extrude into a welded pipe. The appropriate extrusion ratio was selected through investigation of loads using computer simulations. As a result, experiments showed that pipe could be welded and simultaneously extruded with spring type wire material of aluminum. The tensile strength of the welded and extruded aluminum pipe can reach 80% of tensile strength of original aluminum feedstock.

항공기용 배선의 자가소화성에 관한 연구 (A Study on the Self-extinguishing for Aircraft Wire)

  • 정덕영;이백준;이종희
    • 항공우주시스템공학회지
    • /
    • 제5권1호
    • /
    • pp.13-16
    • /
    • 2011
  • All components such as structure, engine, electrical equipment, wire etc. should have certified qualities and functions for safe flight. The wire like a blood vessel of man is connected with most components and supply a electrical signal or power to them and only certified wire through a lot of tests such as rating, flame resistance, self-extinguishing, protection of EMI etc. must be used in aircraft. In other words, the wire should observe many certification requirements because it is one of the most important components.

1MW 고온초전도 동기모터의 개념설계 고찰 (Conceptual Design Considerations of 1MW Class HTS Synchronous Motor)

  • 백승규;손명환;이언용;권영길;문태선;박희주;김영춘
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권3호
    • /
    • pp.38-43
    • /
    • 2004
  • 1MW class superconducting synchronous motor is designed considering several conditions such as superconducting wire length, machine efficiency and size. As the machine is larger and larger, the superconducting machine shows the advantages more and more over the conventional machines. Although the advantages at 1MW rating are not so great, the design approach to get an appropriate result would be very helpful for larger superconducting synchronous machine design. Major design concerns are focused on reducing expensive Bi-2223 HTS(High Temperature Superconducting) wire which is used for superconducting field coil carrying the rating current around 30K(-243$^{\circ}C$) while the machine efficiency is higher than conventional motors or generators with the same rating. Furthermore, some iron cored structure is considered to reduce the HTS wire requirement without bad effect on machine performances such as sinusoidal armature voltage waveform, synchronous reactance and so on.

액체질소에 대한 증발 열전달 촉진 및 압력강하 성능 (Performance of Evaporation Heat Transfer Enhancement and Pressure Drop for Liquid Nitrogen)

  • 남상철;이상천;박병덕
    • 대한기계학회논문집B
    • /
    • 제24권3호
    • /
    • pp.363-372
    • /
    • 2000
  • An experiment was carried out to evaluate the heat transfer enhancement and the pressure drop characteristics for liquid nitrogen using wire-coil-insert technique under horizontal two-phase conditions. The tube inner diameters were 8 mm and 15 mm, respectively and the tube length was 4.7 m. The helix angle of the wire coil insert was $50^{\circ}$ and its length was 4.7 m. Heat transfer coefficients for both the plain and the enhanced test tubes were calculated from the measurements of temperatures, flow rates and pressure drops. A correlation in a power-law relationship of the Nusselt number, Reynolds number and Prandtl number for the heat transfer was proposed which can be available for design of cryogenic heat exchangers. The correlation showed that heat transfer coefficients for the wire-coil inserts were much higher than those for plain tubes, increased by more than $1.8{\sim}2.0$ times depending upon the range of the equivalent Reynolds number. The correlation was compared with other various correlations in the turbulent flow conditions.

펄스 플라스마 반응기에 대한 임피던스 및 누설 인덕턴스 분석 (Analysis of Impedance and Stray Inductance for Pulsed Plasma Reactor)

  • 최영욱;이홍식;임근희;김태희;김종화;장길홍;신완호;송영훈
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권4호
    • /
    • pp.253-260
    • /
    • 1999
  • In this paper, the impedance characteristic of wire-plate pulsed plasma reactor was investigated by experiment. The experiment have carried out under the several conditions of voltage, wire length and wire-plate distance. The impedance of reactor wad decreased with increasing voltage and wire length. The nature of discharge in reactor was changed from streamer corona to spark with increasing incident energy, from which we understood the critical energy density between the two discharges. Fromthis experiment, we proposed the method for the impedance matching between pulse generator and pulsed plasma reactor. Additionally, we succeeded in the analysis ofstray inductance of 0.5MW reactor using EMTP (ElectroMagnetic Transients Program). This means that EMTP is also useful for the analysis of inevitable stray inductance of forthcoming a large scale reactor.

  • PDF

Optimization of wire construction from several 2G HTS tapes

  • Kumarov, D.R.;Sotnikov, D.;Scherbakov, V.I.;Mankevich, A.;Molodyk, A.;Sim, Kideok;Hwang, Soon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권4호
    • /
    • pp.24-28
    • /
    • 2019
  • Despite the second generation HTS tapes (2G HTS tape) have limits in critical current value, scientific and electric devices require more current density day after day. These requirements are realized by using different superconducting wires that consist of 2G HTS tapes designed in various combinations. Authors of this paper have developed the numerical model for estimation of total critical current in the superconducting wire and critical current in each 2G HTS tape placed in this superconducting wire. The current drop in six 2G HTS tapes having different constructions was analyzed. The result of this research is the decrease of critical current up to 25 % for the stack of tapes and up to 5 % for the parallel tapes in the same plane. In addition, what was also made is the estimation of the current distribution by length for six 25 m 2G HTS tapes in different constructions and determination of current deviation by length of the wire.

팔 동작 움직임을 모사하는 와이어 구동 유연 로봇의 설계 및 제어 (Design and Control of Wire-driven Flexible Robot Following Human Arm Gestures)

  • 김상현;김민효;강준기;손승제;김동환
    • 로봇학회논문지
    • /
    • 제14권1호
    • /
    • pp.50-57
    • /
    • 2019
  • This work presents a design and control method for a flexible robot arm operated by a wire drive that follows human gestures. When moving the robot arm to a desired position, the necessary wire moving length is calculated and the motors are rotated accordingly to the length. A robotic arm is composed of a total of two module-formed mechanism similar to real human motion. Two wires are used as a closed loop in one module, and universal joints are attached to each disk to create up, down, left, and right movements. In order to control the motor, the anti-windup PID was applied to limit the sudden change usually caused by accumulated error in the integral control term. In addition, master/slave communication protocol and operation program for linking 6 motors to MYO sensor and IMU sensor output were developed at the same time. This makes it possible to receive the image information of the camera attached to the robot arm and simultaneously send the control command to the robot at high speed.

Transfer length of 2400 MPa seven-wire 15.2 mm steel strands in high-strength pretensioned prestressed concrete beam

  • Yang, Jun-Mo;Yim, Hong-Jae;Kim, Jin-Kook
    • Smart Structures and Systems
    • /
    • 제17권4호
    • /
    • pp.577-591
    • /
    • 2016
  • In this study, the transfer length of 2400 MPa, seven-wire high-strength steel strands with a 15.2 mm diameter in pretensioned prestressed concrete (PSC) beams utilizing high strength concrete over 58 MPa at prestress release was evaluated experimentally. 32 specimens, which have the variables of concrete compressive strength, concrete cover depth, and the number of PS strands, were fabricated and corresponding transfer lengths were measured. The strands were released gradually by slowly reducing the pressure in the hydraulic stressing rams. The measured results of transfer length showed that the transfer length decreased as the concrete compressive strength and concrete cover depth increased. The number of strands had a very small effect, and the effect varied with both the concrete cover depth and concrete strength. The results were compared to current design codes and transfer lengths predicted by other researchers. The comparison results showed that the current transfer length prediction models in design codes may be conservatively used for 2400 MPa high-strength strands in high-strength concrete beams exceeding 58 MPa at prestress release.

강연선의 국부적 손상에 따른 응력 회복길이 분석 연구 (Study on Stress Recovery Length of 7-Wire Strand due to Local Damage)

  • 서동우;김병철;정규산;나원기;박기태
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.150-156
    • /
    • 2017
  • 본 연구는 PSC(Post Tensioned Concrete) 교량 및 사장교(Cable Stayed Bridge) 등에 많이 적용되는 강연선의 국부적 손상에 따른 응력 회복길이를 분석하였다. 강연선은 PC 강선(Prestressing Strand)을 여러 줄을 꼬은 강재이며, 재료의 특성상 준공후 지속적으로 손상이 발생하며 부식 등이 주요 손상원인이다. 이에 따른 손상에 따른 성능저하가 발생하지만, 구조적인 특성상 케이블 내부의 손상 정도 및 응력 변화 패턴을 파악하기 어렵다. 교량에 적용된 케이블의 경우 설치 형상에 따라 채수 등에 따라 부식에 취약한 부분이 발생하며, 이로 인해 국부적인 손상이 발생할 수 있다. 본 연구는 교량 Post-Tensioning 또는 케이블 사장재에 주로 적용되는 강연선(7-Wire Strand)의 국부적 손상에 따른 성능저하 경향 및 응력 회복길이를 FEA 해석을 통하여 분석하였다. 향후 본 연구에서 구축하고자 하는 해석모델을 활용하여 PSC 교량 및 사장교 케이블 등의 안전성 평가 및 잔존수명 예측에 활용될 수 있을 것으로 사료된다.

고온초전도 혼합적층선재의 외부자장 변화에 따른 손실 특설 (Characteristics of AC loss of Hybrid Multi-Stacking with HTS Wires in External Magnetic Field)

  • 임형우;이동민;윤기현;차귀수;이희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.71-73
    • /
    • 2006
  • AC loss on variation of external magnetic field is a very important factor in development of power applications. In this paper, we measured and compared AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires and uniform-multi-stacked wire made of one type of wires, 1G wires or 2G wires. Measurement was performed using by the linked-picked coil method. As results, as the number of wires increase, AC loss per unit volume of both stacked wires in low external magnetic field is reduced. Also AC loss of 2G slacked wire is higher than that of 1G wire. AC loss per unit length of 2G stacked wire is less than that of 1G stacked wire. And AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires was between uniform-multi-stacked wire made of 1G wires and 2G wires.

  • PDF