• Title/Summary/Keyword: wire fixation

Search Result 148, Processing Time 0.026 seconds

THE HEALING OF MANDIBULAR FRACTURE WITHOUT INTERMAXILLARY FIXATION IN A LONG-TERM DISABLED BED PATIENT: REPORT OF A CASE (장기간 침대요양 장애환자에서 악간고정술 없이 치유된 하악 골절: 증례보고)

  • Yoo, Jae-Ha;Choi, Byung-Ho;Lee, Chun-Ui;Kim, Jong-Bae
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.7 no.1
    • /
    • pp.38-43
    • /
    • 2011
  • Treatment of the mandibular fracture consists of reduction and fixation. Primary wire & Arch bar are perhaps the ideal method for intermaxillary fixation. But, daily feeding, swallowing, speech, and in some instances, respiration is difficult to maintain during the period of intermaxillary fixation, owing to muscle weakness, emotional disorder and poor oral hygiene in a position of the long-term bed disabled patient with multiple injuries. Therefore, Intermaxillary fixation is not applied in the disabled bed patient, the alternative methods must be obtained. In the case of the mandibular fracture, because of the absence of weight bearing, osseous union may eventually occur even without immobilization if the patient is maintained without wound infection on a controlled soft diet. For the purpose of the prevention of the wound infection, the establishment of an drainage on the oral lacerated wound is necessary for the removal of the hematoma & seroma in the fracture site. This is the report of a case that was managed conservatively without the intermaxillary fixation in the long-term disabled bed patient with a mandibular compound fracture.

Surgical Experience with Posterior Atlantoaxial Transarticular Screw Fixation in Atlantoaxial Instability (환추-축추 불안정성에 있어서 후방 경관절 나사못 고정술에 대한 수술적 경험)

  • Cha, Seung Kyu;You, Chan Jong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.95-100
    • /
    • 2000
  • Objective : Posterior transarticular screw fixation is known to be one of the best surgical method for the atlantoaxial instability. We assessed the complication and operative risk in 15 patients. Patients and Methods : Between January 1997 and April 1998, 15 patients suffering from this condition were admitted to our institution. Atlantoaxial instability was caused by C1 or C2 fractures in 11, rheumatoid arthritis in 2, and os odontoideum in 2. This technique was used in the treatment of 13 patients and 2 patients was used in sublaminar wire fixation only. Bilateral C1-C2 screws were placed in 11 patients ; 2 patients had only one screw placed becauce of an anomalous vertebral artery and axial destruction. Follow-up period ranged from 5 to 20 months. Results : Most screws were positioned satisfactorily. One screw was malpositioned. No patients had neurological complications. Conclusion : Rigidly fixating C1-C2 instability with transarticular screws showed a significantly higher fusion rate than that achieved using wired grafts alone. The risk of screw malpositioning and catastrophic vascular or neural injury is small and can be minimized by assessing the position of the transverse foramen on preoperative computed tomographic scans and by correctly using intraoperative fluoroscopy and surgeon's precaution.

  • PDF

Limitation of Forearm Rotation after Tension Band Fixation in Olecranon Fracture - Case Report - (장력대 강선 고정법을 이용한 주두 골절의 수술적 치료 후 전완부의 회전운동 제한 - 증례보고 -)

  • Roh, Kwon-Jae;Lee, Churl-Woo;Yun, Yeo-Hon;Shin, Sang-Jin
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.4 no.2
    • /
    • pp.133-137
    • /
    • 2005
  • Tension band wiring of olecranon fractures is recognized as an effective method for fixation and union Complications as non-union, limitation of motion and subcutaneous k-wire protrusion are occasionally reported. But, there are no references about limitation of forearm rotation after tension band fixation. We report two cases of limitation of forearm rotation after tension band fixation of olecranon fracture.

  • PDF

Proximal Symphalangism and Congenital Stapes Fixation (기부지절유합증을 동반한 선천성등골고정증)

  • 이철희;박영원;김종선;노관택
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.41.1-41
    • /
    • 1981
  • The combination of congenital stapes fixation and proximal symphalangism has been described in several kindreds. It exhibits autosomal dominant inheritance. A patient, 11-year-old female, visited department of otolaryngology of SNUH in December, 1980. Her complaint was bilateral hearing loss since birth. Physical examination revealed fusion of proximal interphalangeal joints of both 4th and 5th fingers. Tympanic membrane was normal. Temporal bone X-ray was normal. Pure tone audiogram revealed about 60 dB conductive loss with horizontal curve. On exploratory tympanotomy of right side, bony fixation of stapedial footplate was found. So, stapedectomy with connective tissue wire prosthesis was performed. As a result, marked improvement of hearing was obtained with 5 dB A-B gap on operated side.

  • PDF

THE COMPARATIVE STUDY OF THE EFFECT OF THE SEMI RIGID AND RIGID FIXATIONS OF THE GROWTH OF THE CRANIOFACIAL SKELETON (반강성(半剛性) 및 강성고정(剛性固定)이 두개안면골(頭蓋顔面骨)의 성장(成長)에 미치는 영향(影響)에 관한 연구(硏究))

  • Lee, Sang-Chull;Kim, Yeo-Gab
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.15 no.3
    • /
    • pp.157-170
    • /
    • 1993
  • To prove the effct of semi-rigid fixation which utilize wire and rigid fixation which utilizes miniplate toward cranio-facial growth and development of growing children for teenagers, 28 rabbits-6 weeks, about 1.5kg-were experimented. They were classified three groups the semi-rigid group was 12 rabbits which were fixed with 26 gauge stainless steel wire to cross a fronto-nasal suture, the rigid group was the other 12 rabbits which were fixed with miniplate and screw, the control group was 4 rabbits which were get rid of only periosteum. The sample of fronto-nasal of rabbits which were sacrified after 2 weeks, 4 weeks, 8 weeks, and 12 weeks of the operation were investigated and made a comparative study with the light microscops. 1. At the control group, the central part of bony suture was connected with colagen bundle, the osteoblastic layer was investigated at the bony ending, new bone which covered the inside and outside faces of the bone suture was formed between periosteum. 2. Two weeks later from the experiment, ran slightly irregularly the collagen bundle which connects both bony endings of the rigid group. 3. Four weeks later from the experiment, collagen bundle of bone surface were arranged parally a little and comparing to the semi-rigid group, newly formed woven bone of surface of the adjacent bone was made obviously a little. 4. Eight weeks later from the experiment, collagen bundle which is located between both bony ending become close. Both the semi-rigid group and the rigid group showed significant formation of new bone at the periosteum and the bone surface. 12 weeks later from the experiment, both the semi-rigid group and the rigid group showed the regular running in the collagen bundle and smooth, dense periosteum. Then they assumed a similar aspect of the control group. I think that it does not give the influence to the cranio-facial growth of children or teenager to utilize a rigid fixation for a short period. Because as the time goes on, the surface of the bone suture was recovered and adjacent bone surface of the miniplate fixation showed compensatory growth, although both the semi-rigid group which utilized wire and rigid group which utilized a miniplate brought about the change of the area of the bone suture at the early period.

  • PDF

Development Process of Wire Brush Automatic Transplanter of Plait Fixation Method (엮음고정방식의 와이어 브러시 자동 식모기 개발 프로세스)

  • In-Chul Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.577-584
    • /
    • 2023
  • In this study, among the parts of oil vapor collectors that are already being produced, weaving wire brush automatic transplanters for oil vapor collectors for machine tools of the weaving fixing method, which are not automated due to the specificity of the process and are being produced manually, are developed and reliability is secured through performance evaluation. did Oil vapor collectors play an important role in removing air pollutants and improving air quality, and the coagulation effect of the collection technology is mostly due to brushes. In the experiment, an automatic transplanter was developed to automatically manufacture and produce the wire brush of the oil vapor collector, which is manufactured and used manually. For the experiment of the developed wire brush, an experimental chamber was built, and performance and durability were evaluated through the dust collection efficiency evaluation using the electrostatic precipitator method of contaminants (oil mist). Through this study, we intend to reduce the production time and unit cost of collectors and improve the environment at industrial sites.

Using a Kirschner wire as an internal splint at nasal fractures accompanied fracture of frontal process of maxilla or perpendicular plate of ethmoid (상악골 전두돌기 골절 및 사골 수직판 골절을 동반한 비골 골절에서 K 강선을 이용한 내고정)

  • Rho, Kyoung Hwan;Yoon, Eul Sik;Yoon, Byung Min;Dhong, Eun Sang
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.623-628
    • /
    • 2009
  • Purpose: In cases where nasal fractures involve frontal process of maxilla or perpendicular plate of ethmoid, 4 - 5 days of nasal packing may not provide sufficient support for avoiding displacement after packing removal. Therefore a single Kirschner - wire(K - wire) is used as an internal splint when nasal fractures involve the above two areas. Methods: Thirty five patients during the last 3 practical years were treated with a K -wire pinning according to the anatomic locations of nasal fractures. We performed a retrospective study using 13 nasal fractures out of total 35 patients. Among 13 cases, 10 patients involved frontal process of maxilla, and 3 patients were diagnosed as bilateral nasal side wall fractures accompanied with fractures of perpendicular plate of ethmoid. One patient of the last three cases had been augmented with dorsal silicone implant long before the trauma. We analyzed the anteroposterior displacement of key stone area and the width between both lateral walls by comparing immediate postoperative radiographs with 2 month follow - ups. To reduce the errors, the same measurements were taken by two different inspectors, and the mean of each inspector's measurements was compared. Patient satisfaction was analyzed using a questionnaire regarding the esthetic and functional outcomes. Results: Ten patients underwent a longitudinal K - wire fixation in submucoperiosteal plane underneath the frontal process of maxilla. And three patients underwent a transverse K - wire fixation from the one side of lateral wall to the perpendicular plate of ethmoid and to the other side of lateral wall. The mean postoperative anteroposterior displacement of the key stone area measured by two inspectors were 1.84% and 3.06%; mean narrowing of bony pyramid were 1.33% and 1.48%, respectively. Subjective satisfaction scores regarding the esthetic appearance and the maintenance of nasal shape compared with immediate post - operative state with the long term ones were not different (p>0.05). Conclusion: K - wire pinning after closed reduction is a reliable and useful method for the treatment of nasal fractures involving frontal process of maxilla or perpendicular plate of ethmoid. This is because it achieves longer intranasal support after reduction. This method also leaves conspicuous external scar, and minimal soft - tissue injury.

Arthroscopic Pull-out Wire Fixation Using Cannulated Screw of Tibial Eminence Fractures (도관 나사못을 이용한 경골 과간 융기 골절의 관절경적 견인 봉합술)

  • Kim, Jong-Min;Kim, Hyung-Gyu;Park, Byeong-Mun;Song, Kyeong-Seop;Jung, Sung-Hoon;Noh, Haeng-Kee;Yoon, Jong-Joo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.3
    • /
    • pp.254-258
    • /
    • 2009
  • Tibial eminence fracture is caused by distortion, excessive flexion and extension, varus and valgus injury of the knee joint in the form of avulsion fracture. A failure over the exact anatomical reduction of fragment can lead to instability and limitation of joint motion. Recently, a variety of arthroscopic assisted reduction and fixation technique have been used. In the tibial eminence fracture, we created an arthroscopic pull-out wire fixation technique using a cannulated screw that is easy and more convenient than in the conventional technique. So we report this technique with a review of current literatures.

  • PDF

Migration of Early Broken Wire into the Popliteal Fossa through Popliteal Hiatus in Internally fixed Fracture of Patella - A Case Report - (내고정한 슬개골 골절에서 슬와공을 통한 조기 파절된 강선 조각의 슬와부로의 이동 - 증례보고 -)

  • Jeon, Ho-Seung;Jeon, Seung-Ju;Moon, Chan-Sam;Noh, Hang-Gi;Jeong, Hyung-Jun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.170-173
    • /
    • 2009
  • Wiring techniques in the fixation of patellar fracture are commonly used. Rigid fixation is essential for early rehabilitation. Breakages of wires after the fixation of patellar fracture are common with extracapsular migration if not removed for long term. But, we experienced a case of patellar fracture with early breakage of wiring and migration of the broken wire fragment into the popliteal fossa through the popliteal hiatus in 64- year-old man and we successfully treated this case, using both arthroscopic and open procedures. So we report this unusual case with a review of current literatures.

  • PDF