• Title/Summary/Keyword: wire fixation

Search Result 148, Processing Time 0.02 seconds

Surgical Treatment of the Fifth Metatarsal Base Fracture Using Multiple Kirschner Wires (다발성 Kirschner 강선을 이용한 제 5중족골 기저부 골절의 수술적 치료)

  • Kim, Jihyeung;Kim, Jang Woo;Lee, Jeong Ik;Kim, Sang Kil;Rhee, Seung Hwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.1
    • /
    • pp.24-28
    • /
    • 2014
  • Purpose: The purpose of this study is to evaluate the clinical and radiographic results of internal fixation using multiple Kirschner wires (K-wires) for the fifth metatarsal base fracture. Materials and Methods: We retrospectively reviewed 14 patients with a displaced fifth metatarsal base fracture. We measured the distance of fracture displacement on the foot oblique radiograph pre- and post-operatively. We evaluated the clinical results using the visual analog pain scale at six weeks and three months postoperatively and the American Orthopaedic Foot and Ankle Society (AOFAS) mid-foot score at six months postoperatively. Results: In our series, 10 cases were zone I fracture and four cases were zone II fracture. We achieved anatomical reduction and bony union in all of our cases. The average time to bone union was 43 days. The degree of pain around the fifth metatarsal base was significantly decreased after surgery. The average AOFAS score was 95 at six months postoperatively. Conclusion: Multiple K-wire fixation is a relatively simple fixation method for displaced fifth metatarsal base fractures. If we place a K-wire into the medial cortex of the fifth metatarsal, we could prevent proximal migration of the K-wire.

Arthroscopic Treatment of Fractures of the Intercondylar Eminence of the Tibia Using Pull-Out Wire (견인강선을 이용한 경골극 견열 골절의 관절경적 치료)

  • Kim, Hyun Kon;Kim, Sung Jae;Hahn, Myung Hoon;Kang, Yong Ho;Jung, Hwan Yong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.45-50
    • /
    • 1998
  • Recently, a variety of arthroscopic techniques have been reported for the treatment of the displaced tibial eminence fracture. The purpose of this study was to describe details of arthroscopic technique using pull-out wire and to evaluate the results. Eleven patients with irreducible type II and type III tibial eminence fractures underwent the arthroscopic reduction and internal fixation using double strand pull-out wiring. The anterior cruciate ligament tibial drill guide was utilized for the reduction of fracture and passage of the guide pins. The tibial eminence fracture was firmly fixed with double strand 26-gauge pull-out wire(0.45mm diameter). Fracture union was achieved at 7.2 weeks (range, six to eight weeks) after operation. All cases were united at the last follow-up. Subjectively, nine patients had no pain and no restriction of daily activities. Two patients with combined injuries had limitation of knee motion(10 to 130 degrees, respectively) and one patient showed mild anterior laxity. Early rehabilitation was enabled without loss of reduction and breakage of pull-out wire. The arthroscopic reduction and internal fixation using pull-out wire showed good results including early rehabilitation, early fracture union, minimal morbidity, and no requirement of the second operation for hard ware removal.

  • PDF

Surgical Management of Comminuted Midshaft Clavicle Fractures Using Reconstruction Plate and Circumferential Wiring: Does the Circumferential Wiring Interfere with the Bone Union? (쇄골 간부 복합 골절에서 재건 금속판 및 환 강선을 이용한 수술적 치료: 환 강선이 골 유합을 방해하는가?)

  • Kim, Kyung-Tae;Shin, Chung-Shik;Park, Young-Chul;Kim, Dong-hyun;Kim, Min-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.245-252
    • /
    • 2021
  • Purpose: This study examined the radiological and clinical outcomes of internal fixation using a reconstruction plate and 21G circumferential wire in comminuted midshaft clavicular fractures. Materials and Methods: A retrospective cohort study was performed on 51 patients between 2005 and 2019. Thirty-two patients underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and 19 patients underwent surgery without a wire. The patients were assessed with the radiographic parameters, the University of California at Los Angeles (UCLA) score, and the visual analogue scale (VAS) pain score. Based on this, patients who operated without a circumferential wire were set as the control group, and the differences in bone union between the two groups were compared. Results: Thirty-two patients were followed-up for an average of 65 weeks, and 19 patients in the control group were followed-up for an average of 56 weeks. The radiological evaluation confirmed the anatomical reduction and bone union in all 32 patients. No case of nonunion was present. The UCLA score was 32.38 on average and 33.11 in the control group (p=0.395). The VAS score was 1.00 on average and 0.84 in the control group (p=0.668). A significant difference in the bony union time was observed between the group who underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and the control group (p=0.015). On the other hand, there was no statistical significance when other variables were controlled (p=0.107). Conclusion: For displaced midshaft clavicular fractures, internal fixation using a reconstruction plate and 21G circumferential wire maintained accurate anatomical reduction. The satisfactory clinical and radiological results mean that internal fixation using a reconstruction plate and 21G circumferential wire may be a good option for surgical treatment.

Reduction Loss after Extension Block Kirschner Wire Fixation for Treatment of Bony Mallet Finger (골성 추지 신전제한 K 강선 고정술 시행 후 정복소실)

  • Kim, Byungsung;Nho, Jae-Hwi;Jung, Ki Jin;Yun, Keonhee;Park, Eunseok;Park, Sungyong
    • Archives of Hand and Microsurgery
    • /
    • v.23 no.4
    • /
    • pp.239-247
    • /
    • 2018
  • Purpose: We investigated occurrence of reduction loss after extension block (EB) Kirschner wire fixation or additional interfragmentary fixation (AIF) and clinical results including extension lag of the distal interphalangeal joint for treating bony mallet finger. Methods: Forty-six patients were included with a mean follow-up of 28 months (range, 12-54 months). Twenty-seven patients were treated with EB K-wire fixation (Group A) while 19 patients were treated with AIF (Group B). We checked radiologic factors, such as amount of articular involvement, volar subluxation, mallet fragment angle, reduction loss, range of motion including extension lag, and functional outcomes using Crawford's criteria. Results: Reduction loss occurred in eight patients (17%). Differences in mean extension lag, age, preoperative volar subluxation and mallet fragment angle between patients with reduction loss and those with reduction maintaining were significant. However, there were no significant differences in gender, hand dominance, amount of articular involvement, AIF, or further flexion between reduction loss and reduction maintaining. As for patterns of displacement, there was a significant relationship between gap or step-off and extension lag. Using Crawford's evaluation criteria, functional outcomes were excellent in 31, good in 10, fair in 3, and poor in 2 patients. Conclusion: Reduction loss should be careful in older age, smaller mallet fragment angle and preoperative volar subluxation.

Intracardiac a Aortic Foreign Body (심장 및 대동맥내 이물 치험 1례)

  • 방정희;편승환
    • Journal of Chest Surgery
    • /
    • v.30 no.9
    • /
    • pp.932-935
    • /
    • 1997
  • A 50-year-old male patient was admitted due to right ventricular & aortic foreign bodies with ascending aortic pseudoaneurysm. The patient had a history of Kirschner wire fixation of right sternoclavicular joint 3 months ago. Under cardiopulmonary bypass, two K-wires were removed and injured pulmonary valve leaflet and aortic wall were repaired successfully The postoperative course was uneventful and the patient was discharged on the 14th postoperative day.

  • PDF

Removal of Kirschner Wire That Migrated from the Pelvic Bone into the Right Ventricle of the Heart

  • Kim, Ji-Eon;Jung, Sung-Ho;Cho, Won-Chul;Byun, Joung-Hun
    • Journal of Chest Surgery
    • /
    • v.44 no.3
    • /
    • pp.250-252
    • /
    • 2011
  • A sixty-year-old man was admitted due to chest pain. He had a history of pelvic bone fracture fixation with Kirschner wire about 20 years earlier. On examination, we detected a Kirschner wire that had migrated into the right ventricle. Without cardiopulmonary bypass, we removed the migrating Kirschner wire via median sternotomy. The patient recovered without complications and was discharged on the 5th postoperative day.

Internal Fixation of Long Bone Fractures in 6 Calves (송아지에서 발생한 긴뼈골절의 내고정 치료 6례)

  • Park, Jin-Uk;Cho, Ki-Rae;Kim, Joong-Hyun;Choi, Seok-Hwa;Kim, Gon-Hyung
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.658-662
    • /
    • 2007
  • The simple and easy treatment with cast or splint has been applied to stabilize long bone fractures in farm animals. Applying cast or splint is relatively easier than surgical fixation and may temporarily stabilize fracture site. However, the internal fixation provides strong stabilization and early recovery of limb function. In this report, we describe six cases of limb fractures in calves repaired by internal fixation. Fracture sites are various and affected ages are between 1 day and several months old. In some cases, patients were treated with cast or splint before admitting to Veterinary Medical Center. In these patients, regardless of initial treatment fractures were not immobilized. Consequently we decided to treat these patients with open reduction and internal fixation. The fracture repair with implants(bone plate, screw, cerclage wire, and intramedullary pin) were effective and satisfactory in calves which had been failed by application of cast. Although the cost of orthopedic treatment in farm animal is one of the most important considerations from the practical point of view, internal fixation has many benefits in newborn and young calves. And simplicity of postoperative management is also practically significant benefit expected from infernal fixation In conclusion, we suggest that internal fixation will produce better result than external coaptation in calve.

Additional fixation using a metal plate with bioresorbable screws and wires for robinson type 2B clavicle fracture

  • Shin, Woo Jin;Chung, Young Woo;Kim, Seon Do;An, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.4
    • /
    • pp.198-202
    • /
    • 2020
  • Simple clavicle fractures can achieve satisfactory results through conservative treatment, and the less frequency of nonunion. Non-union or malunion can occur in displaced clavicle fractures or comminuted shaft fractures. Treatment of displaced comminuted clavicle shaft fractures is performed by holding together the free fragments with interfragmentary screws or wires and fixing them to the clavicle with a plate. Therefore, we performed interfragmentary fixation using open reduction and internal fixation with bioresorbable screws (Mg-Ca alloy, Resomet bioresorbable bone screw; U&I Corp.) and bioresorbable wires (Mg-Ca alloy, Resomet bioresorbable K-wire and pin, U&I Corp.) for displaced comminuted clavicle fractures (Robinson type 2B) and additionally used a metal plate. We expected decreased irritation and infection due to absorption after surgery. We report four cases that were treated in this way.

Limited internal fixation for the treatment of the Ovadia and Beals type II or III Pilon fracture (Ovadia와 Beals 제2형 또는 3형 경골 천정 골절의 제한적 내고정술을 이용한 치료)

  • Kim, Hyoung-Chun;Kim, Kwang-Yul;Lim, Mun-Sup;Kim, Jin-Hyoung;Kwon, Joon-Hyoung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.2
    • /
    • pp.250-257
    • /
    • 2003
  • Purpose: Pilon fracture is caused by high energy and axial compression forces, and it is often associated with severe comminution and soft tissue injury. Recently, limited internal fixation of this fracture may avoid the soft tissue complications associated with formal open reduction and internal fixation and avoid incongruity of joint margin associated with conservative treatment. We have treated Ovadia and Beals type II or III pilon fracture with limited internal fixation and the results were satisfactory. Materials and Methods: We analyzed 15 cases of Ovadia and Beals type II or III fractures who were treated by limited internal fixation(K-wire or screw fixation) from January 1995 to December 2000. The average follow up period was 20 months(range, 12 to 38 months). According to the Ovadia and Beals classification, seven cases were type II, and eight cases were type III. Radiographic results were assessed by Ovadia and Beals criteria. We also assessed the functional results by Mast and Teipner criteria. Results: Radiographic results showed good in 67% and fair in 33% of cases. Clinical results showed good in 73% and fair in 27% of cases. There were no complications such as wound infection and skin necrosis, but traumatic arthritis were 2 cases. Conclusion: Pilon fractures are high energy injuries with significantly associated soft tissue damage and traumatic arthritis. Limited internal fixation offers good solution to Ovadia and Beals type II or III fracture.

  • PDF

Microplate Fixation without Maxillomandibular Fixation in Double Mandibular Fractures

  • Song, Seung Wook;Burm, Jin Sik;Yang, Won Yong;Kang, Sang Yoon
    • Archives of Craniofacial Surgery
    • /
    • v.15 no.2
    • /
    • pp.53-58
    • /
    • 2014
  • Background: Maxillomandibular fixation (MMF) is usually used to treat double mandibular fractures. However, advancements in reduction and fixation techniques may allow recovery of the premorbid dental arch and occlusion without the use of MMF. We investigated whether anatomical reduction and microplate fixation without MMF could provide secure immobilization and correct occlusion in double mandibular fractures. Methods: Thirty-four patients with double mandibular fractures were treated with open reduction and internal fixation without MMF. Both fracture sites were surgically treated. For bony fixations, we used microplates with or without wire. After reduction, each fracture site was fixed at two or three points to maintain anatomical alignment of the mandible. Interdental wiring was used to reduce the fracture at the superior border and to enhance stability for 6 weeks. Mouth opening was permitted immediately. Results: No major complications were observed, including infection, plate exposure, non-union, or significant malocclusion. Five patients experienced minor complications, among whom the only one patient experienced a persistant but mild malocclusion with no need for additional management. Conclusion: This study showed that double mandibular fractures correction with two-or three-point fixation without MMF simplified the surgical procedure, increased patient comfort, and reduced complications, due to good stability and excellent adaptation.