• Title/Summary/Keyword: winding methods

Search Result 143, Processing Time 0.027 seconds

Study on Surge Voltage Distribution Design for UHV Transformer Windings by Finite Element Method (유한요소법에 의한 초고압변압기권선의 충격파전위분포설계에 관한 연구)

  • 황영문;이일천
    • 전기의세계
    • /
    • v.28 no.11
    • /
    • pp.45-51
    • /
    • 1979
  • Finte element methods are developed for the initial distribution problems which contain the surge potential circuits of high voltage transformer windings. The initial distribution of surge voltages in transformer windings are useful to the work to a practical engineering basis. However, the conventional methods of analyzing them so far are much complicated for practical designs. In this paper, the ability to solve surge potential field problems underlies the development of descreting methods to a lodal capacitive distribution-coefficients for determing the surge voltage relationship among a set of transformer coils. A practical example-the modeling of an antioscillation shield coil winding and hisercap winding is used to illustrate and evaluate these methods.

  • PDF

Electromagnetic Force Calculation of Internet Winding Fault in A Distribution Power Transformer by using A Numerical Program (수치해석을 이용한 배전용 변압기 권선 고장시의 전자력 계산방법 연구)

  • Shin, Pan-Seok;Ha, Jung-Woo;Chung, Hee-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.60-67
    • /
    • 2007
  • In this paper, a simulation method of the internal winding fault is proposed to calculate winding current and electromagnetic force in a distribution power transformer by suing FEM program. The model of the transformer is a single phase, 60[Hz], 1[MVA], 22.9[kV]/220[V], cable-type winding. The short-circuit current and electromagnetic force are calculated by FEM(Finite Element Method) program(Flux2D) and the results we verified with theoretical formula and PSPICE program. The simulation results are fairly good agreement with the other verified methods within 5[%] error rate. The turn-to-turn short-circuit current is 500 times of the rated current and the electromagnetic force is about $20{\sim}200times$. The method presented in this study may serve as one of the useful tools in the electromagnetic force analysis of the transformer winding behavior under the short circuit condition for design of the structure.

A Study on the Magnetic Field Analysis and Leakage Inductance in Current Transformers by 3D Integral Methods (3차원 적분법을 이용한 변류기의 자계해석과 누설 인덕턴스에 대한 연구)

  • 이희갑;박용필
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.9
    • /
    • pp.768-772
    • /
    • 2001
  • This paper presents leakage magnetic field and leakage inductance calculations in current transformer by means of 3-D Integral methods. From the distribution diagram of leakage magnetic flux to be analyzed using program called TRACAL 3, ti confirms a parallel to the winding axis direction of the leakage flux lines in the air gap between the windings. The leakage inductances L$\sub$r1/ and L$\sub$r2/ of the primary and secondary winding were calculated, their values are 4.23 MH and 0.49 mH, respectively. They are also similar to the measured values of he leakage inductances of the experimental verification, 4.06 mH and 0.47 mH.

  • PDF

Electromagnetic Analysis of Transformer windings (변압기용 권선의 전자장 해석)

  • 박찬배;김우석;한송엽;최경달;주형길;홍계원
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.225-228
    • /
    • 2002
  • This paper presents electro-magnetic analysis of IMVA High T$_{c}$ Superconductivity transformer designed conceptually. A winding type of this transformer is a double pancake type, and a transformer of solenoidal winding type is selected to be compared with it. Both transformers have the same sizes and the same turns. Results of the analysis are compared with results of solenoidal winding. And, in this paper, leakage inductances are calculated too. There are a lot of methods to calculate inductance including Neumann Formula, Energy conservation and so on. In this paper, Energy conservation method are selected.d.

  • PDF

Applications of Fiber Bragg Grating Sensor Technology (FBG 센서 기술의 응용 사례)

  • Kang Dong-Hoon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.3-9
    • /
    • 2006
  • Among many fabrication methods of composite materials, filament winding is the most effective method for fabricating axis-symmetric structures such as pressure tanks and pipes. Filament wound pressure tanks are under high internal pressure during the operation and it has the complexity in damage mechanisms and failure modes. Fiber optic sensors, especially FBG sensors can be easily embedded into the composite structures contrary to conventional electric strain gages (ESGs). In addition, many FBG sensors can be multiplexed in single optical fiber using wavelength division multiplexing (WDM) techniques. In this paper, we fabricated several filament wound pressure tanks with embedded FBG sensors and conducted some kinds of experiments such as an impact test, a bending test, and a thermal cycling test. From the experimental results, it was successfully demonstrated that FBG sensors are very appropriate to composite structures fabricated by filament winding process even though they are embedded into composites by multiplexing.

  • PDF

A Study of The Deterioration Characteristics due to Heat Cycle of Generator Stator Windings (발전기 고정자권선의 히트사이클에 의한 열화특성에 관한 연구)

  • Kim, H.G.;Kim, T.S.;Park, M.S.;Park, C.H.;Song, U.C.;Park, Y.G.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.379-381
    • /
    • 1995
  • Many generating stations in korea are 25 years or more old, and are nearing the end of their planned life. Financial conditions and Site, Environment problems have made approval for construction of new stations increasingly difficult, and extending the life of an existing older plant may be a palatable alternative. Therefore, To determine whether generator rewinds are necessary to achieve an extended life, and Methods are required to estimate the proable remaining life of existing winding, here, We are going to estimate insolation condition through Nondestructive diagonostic test and Aging history tests of generator Stator winding and winding conditions through deterioration characteristics due to Heat cycle.

  • PDF

Calculation of Distributed Magnetic Flux Density under the Stator-Turn Fault Condition

  • Kim, Kyung-Tae;Hur, Jin;Kim, Byeong-Woo
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.552-557
    • /
    • 2013
  • This paper proposed an analytical model for the distributed magnetic field analysis of interior permanent magnet-type blush-less direct current motors under the stator-turn fault condition using the winding function theory. Stator-turn faults cause significant changes in electric and magnetic characteristic. Therefore, many studies on stator-turn faults have been performed by simulation of the finite element method because of its non-linear characteristic. However, this is difficult to apply to on-line fault detection systems because the processing time of the finite element method is very long. Fault-tolerant control systems require diagnostic methods that have simple processing systems and can produce accurate information. Thus analytical modeling of a stator-turn fault has been performed using the winding function theory, and the distributed magnetic characteristics have been analyzed under the fault condition. The proposed analytical model was verified using the finite element method.

Design of Traverse earn for Yarn Winding on Twisting Machine

  • Kim Jong-Soo;Yoon Ho-Eop;Kim Dae-Won
    • Fibers and Polymers
    • /
    • v.6 no.2
    • /
    • pp.151-155
    • /
    • 2005
  • A twisting machine is to twist yarns for improving yam strength. After twisting yams, the twisting machine winds yams into a bobbin. The traverse mechanism is very important part of winding mechanism. Because it performs uniform winding onto the bobbin. the traverse cam is the main part of the traverse mechanism. This paper proposes design method of the traverse cam using the relative velocity method [4,5]. The relative velocity method is used to calculate the relative velocity of the follower versus the cam at the center of roller, and then to determine the contact point using the geometric relationship and kinematical constraints. Finally, we present examples verifying the accuracy of the proposed methods.

Study of Winding Method to Reduce Stray Loss and Stator Core Vibration of Synchronous Machine

  • Hiramatsu, Daisuke;Sutrisna, Kadek Fendy;Ishizuka, Hiroaki;Okubo, Masashi;Tsujikawa, Kazuma;Ueda, Takashi;Hachiya, Hideyuki;Mori, Junji;Aso, Toshiyuki;Otaka, Toru
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.3
    • /
    • pp.313-320
    • /
    • 2013
  • The fractional slot windings are widely used in rotating machine in order to increase the flexibility of design and improve the voltage waveform. However, the MMF wave of fractional-slot windings are found to contain unique harmonic component, which are designated as even order space flux harmonics, fractional number flux harmonics, or both. They may cause stray loss and stator core vibration. This paper proposes new winding methods "novel interspersed windings" and "expanded group windings" to reduce these harmonics. The advantages of two proposed windings are verified by using numerical analysis and measurement test of winding model.

A New PWM DC/DC Converter with Isolated Dual Output Using Single Power Stage

  • Lee, Dong-Yun;Hyun, Dong-Seok;Ick Choy
    • Journal of Power Electronics
    • /
    • v.2 no.4
    • /
    • pp.312-324
    • /
    • 2002
  • This paper presents a new PWM DC/DC converter with dual output power using single power stage, which has the isolation characteristics between each dual output. The proposed converter topology consists of two switches ($S_B$ and $S_F$) and only single secondary winding. Therefore, the proposed converter has better advantages of not only low cost and small size but also high power density because of using minimum components and devices compared with conventional methods which use multi winding transformers or several converters. The operating principle of the proposed converter topology, which includes the conventional auxiliary ZVT (Zero-Voltage-Transition) circuit to implement soft switching of the main switch, is illustrated in detail and the validity of the proposed converter is verified through several simulated and experimental results.