• Title/Summary/Keyword: wind-heat

Search Result 835, Processing Time 0.024 seconds

Experimental Study on Heat Losses from Receiver of Solar Thermal Power (태양열발전용 흡수기 설게 및 열손실 특성실험)

  • Kim, Jong-Kyu;Kang, Yong-Heack;Kim, Jin-Soo;Lee, Sang-Nam;Yu, Chang-Kyun;Yun, Hwan-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.672-675
    • /
    • 2007
  • Experimental data are presented which describe heat losses of cavity type receiver in wind tunnel. Experiments are conducted at various conditions such as the heater temperature in cavity changes from 300, 400, and 500 oC, wind speed in tunnel from 2 to 8 m/s, and four different tilt angle of 30, 50, 70, 90o. The power consumption including temperature, voltage and current for each experimental conditions are measured and stored in data logger at everyone second interval. The experimental results show that heat losses increase with increasing wind speed and with tilt angle. However, heat losses for the tilt angle of 70 and 90o is almost same at each heater temperature. In addition, the effects of natural convection in combined convection heat losses vary in according to the tilt angle.

  • PDF

Numerical Analysis of Convective Heat and Mass Transfer around Human Body under Strong Wind

  • Li, Cong;Ito, Kazuhide
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.2
    • /
    • pp.107-116
    • /
    • 2012
  • The overarching objective of this study is to predict the convective heat transfer around a human body under forced strong airflow conditions assuming a strong wind blowing through high-rise buildings or an air shower system in an enclosed space. In this study, computational fluid dynamics (CFD) analyses of the flow field and temperature distributions around a human body were carried out to estimate the convective heat transfer coefficient for a whole human body assuming adult male geometry under forced convective airflow conditions between 15 m/s and 25 m/s. A total of 45 CFD analyses were analyzed with boundary conditions that included differences in the air velocity, wind direction and turbulence intensity. In the case of approach air velocity $U_{in}=25m/s$ and turbulent intensity TI = 10%, average convective heat transfer coefficient was estimated at approximately $100W/m^2/K$ for the whole body, and strong dependence on air velocity and turbulence intensity was confirmed. Finally, the formula for the mean convective heat transfer coefficient as a function of approaching average velocity and turbulence intensity was approximated by using the concept of equivalent steady wind speed ($U_{eq}$).

Effect of Operating Conditions of a Fan-Coil Unit with an Oval Tube Type Heat Exchanger on Non-Dimensional Performance Coefficient (타원관 열교환기를 적용한 팬코일 유닛의 운전 조건이 무차원 성능계수에 미치는 영향)

  • Yoon, Jaedong;Lee, Younghoon;Sung, Jaeyong
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • In this study, the effect of operating conditions of fan-coil unit with an oval tube type heat exchanger on its non-dimensional performance coefficient has been investigated. Pressure drops and heat transfer rates were measured under heating condition for various water flow rates, inlet temperatures and wind speeds. As a non-dimensional performance coefficient, Colburn j-factor was evaluated. The results show that the most sensitive parameter on heat flux is the inlet temperature, which affects the heat flux 4.7 and 7.2 times more than the wind speed and water flow rate, respectively. On the other hand, the Colburn j-factor as a non-dimensionalized index decreases with the wind speed, and has an maximum when the wind speed is about 1 m/s. the Colburn j-factor increases slowly with the water flow rate and inlet temperature but at a certain range of inlet temperature, the opposite phenomenon is found.

Temporal and Spatial Characteristics of Sea Surface Winds over the Adjacent Seas of Korean Peninsular - Spectral Analysis.

  • Lee, Heung-Jae;Na, Jung-Yul;Han, Sang-Kyu
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.20-25
    • /
    • 1995
  • Surface wind field over an ocean plays a very important role not only to generate wind-driven current, but also to control heat exchange between ocean and atmosphere. However, the surface wind-field used for the ocean circulation and heat exchange is usually estimated by indirect methods because of lack of observed wind data and incomplete spatial coverage. (omitted)

  • PDF

Comparative Analysis of Wind Flows in Wind Corridor Based on Spatial and Geomorphological Characteristics to Improve Urban Thermal Environments (도시 열환경개선을 위한 공간지형적 특성에 따른 바람길 유동 비교 분석)

  • SEO, Bo-Yong;JUNG, Eung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.2
    • /
    • pp.75-88
    • /
    • 2017
  • This study analyzed wind flows based on spatial and geomorphological characteristics of Daegu Metropolitan City. A three-stage analysis was performed, starting with a comparison of meteorological relationships between local wind direction (synoptic wind) and local wind flow. In the second stage the study area was subdivided into districts and suburban districts to analyze the relative change of local wind flow. In stage three, the formation of wind corridor for local wind flow, wind flow for the entire urban space, and spatial relationships between flows were verified comparatively using KLAM_21. Three results are notable, the first of which is a low correlation between synoptic wind of a region, and local wind, flow in terms of meteorology. Secondly, observations of local wind flow at five downtown districts and two suburban districts showed that there were diverse wind directions at each measurement point. This indicates that the spatial and geomorphological characteristics of areas neighboring the measurement points could affect the local wind flow. Thirdly, verifying the results analyzed using KLAM_21, compared to Atomatic Weather System(AWS) measurement data, confirmed the reliability of the numerical modelling analysis. It was determined that local wind flow in a city performs a spatial function and role in ameliorating the urban heat island phenomena. This indicates that, when an urban planning project is designed, the urban heat island phenomena could be ameliorated effectively and sustainably if local wind flow caused by immediate spatial and geomorphological characteristics is confirmed systematically and techniques are intentionally applied to connect the flows spatially within areas where urban heat islands occur.

Effect of Flue Gas Heat Recovery on Plume Formation and Dispersion

  • Wu, Shi Chang;Jo, Young Min;Park, Young Koo
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.161-172
    • /
    • 2012
  • Three-dimensional numerical simulation using a computational fluid dynamics (CFD) was carried out in order to investigate the formation and dispersion of the plume discharged from the stack of a thermal power station. The simulation was based on the standard ${\kappa}{\sim}{\varepsilon}$ turbulence model and a finite-volume method. Warm and moist exhaust from a power plant stack forms a visible plume as entering the cold ambient air. In the simulation, moisture content, emission velocity and temperature of the flue gas, air temperature and wind speed were dealt with the main parameters to analyze the properties of the plume composed mainly of water vapor. As a result of the simulation, the plume could be more apparent in cold winter due to a big difference of latent heat capacity. At no wind condition, the white plume rises 120 m upward from the top of the stack, and expands to 40 m around from the stack in cold winter after flue gas heat recovery. The influencing distance of relative humidity will be about 100 m to 400 m downstream from the stack with a cross wind effect. The decrease of flue gas temperature by heat recovery of thermal energy facilitates the formation of the plume and restrains its dispersion. Wind speed with vertical distribution affects the plume dispersion as well as the density.

Seven Cases of Seborrheic Dermatitis Patients Treated with Sihochunggan-tang gagambang (시호청간탕가감방(柴胡淸肝湯加減方)으로 치료한 지루성피부염 치험 7례)

  • Lee, In-Hye;Lee, Hyung-Tak;Kwon, O-Yong
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.28 no.2
    • /
    • pp.130-142
    • /
    • 2015
  • Objective : The purpose of this case study is to report the effectiveness of Sihochunggan-tang gagambang in respect of liver meridian wind-heat or liver-heat on 7 seborrheic dermatitis patients who were in high stress and had unhealthy dietary habit. Methods : VAS (Visual Analogue Scale) score was used to check the prognosis of 7 seborrheic dermatitis patients, who have been treated with Sihochunggan-tang gagambang and acupuncture. Results : VAS score decreased as a result of Sihochunggan-tang gagambang treatment in 7 patients. Conclusion : Sihochunggan-tang gagambang can be effective treatment for the high stress and unhealthy diet related seborrheic dermatitis when diagnosed as liver meridian wind-heat or liver-heat

A Research on the Deliria speech of "Sanghanmyeonglisoglon(傷寒明理續論)" ("상한명리속론(傷寒明理續論)" 중 섬어외 8증(證)에 대한 연구(硏究))

  • Choi, Dong-Su;Sheen, Yeong-Il
    • Journal of Korean Medical classics
    • /
    • v.19 no.4
    • /
    • pp.241-256
    • /
    • 2006
  • Aversion to wind is a feeling of cold when exposed to wind; aversion to cold is a feeling of cold. The distinction between aversion to wind and aversion to cold is ambiguous because in greater yang disease the two terms seem to be used indiscriminately. It is, however, worth noting that "aversion to wind" does not occur in the lines presenting disease of the three yin. In this text, we render as "heat effusion" rather than "fever," since the Chinese term is somewhat wider in meaning than familiar English term, Heat effusion is associated with many conditions and occurs both in externally contracted disease and miscellaneous disease (雜病), disease due to causes other than external evils). In externally contracted disease of the three yang channels, heat effusion is a manifestation of the struggle between right qi and evil qi; it does not necessarily indicate the presence of evil heat. In diseases of the three yin, right qi is not strong enough to counter evil qi; hence heat effusion is absent, and instead only aversion to cold is present. Sweating occurs in a variety of patterns. A distinction is made between spontaneous and night sweating(自汗). Spontaneous sweating is so called because it occurs spontaneously without exertion. it has numerous causes. Night sweating(盜汗) is sweating during sleep that ceases on awakening.

  • PDF

A Study on the Micro-climate of the City to Construct Wind Ways (바람길 조성을 위한 도시미기후 측정 분석)

  • Jeon, Ji-Hyeon;Park, Seok-Bong
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.111-118
    • /
    • 2005
  • The purpose of this study is to address the progress of the heat island phenomenon and the scheme to decrease in heat island phenomenon through analysis of micro-climates according to land use and make a plan to construct wind ways. The result is: 1) Analysis of temperature and humidity at 6 spots for 24 hours showed that heat island phenomenon was considerably intense around center road of Gwangju and can be mild through making lakes and green zones. 2) Analysis of the direction and velocity of the wind at 2 spots for 24 hours showed that the direction of the wind at the center of Gwangju was SSW(South-South-West) and average velocity of the it was $1.2{\sim}1.5\;m/s$. To make the inflow of the low-temperature air current from Mt. Mudeung into the city through Gwangju river, efficient management of Gwangju riverside parks should be considered for Gwangju river itself to be wind way. 3) Analysis of mobile temperature measurement on 3 courses for 24 hours showed that the low-temperature air current of Mt. Mudeung and a micro-climate of Gwangju river can lighten thermal storage phenomena of the city in that the temperature was lowest at Gwangju riverside. These outcome is from a day term measurement. So, to figure out accurate condition of heat island phenomenon in Gwangju City, it is needed to have long term measurements and accumulation of those information.

Particulate Two-Phase Flow Analysis for Fouling Prediction(I)-Design of Hot Wind Tunnel and Its Performance Experiment- (파울링 예측을 위한 가스-입자 이상 유동 해석(1)-고온 풍동 설계 및 성능실험-)

  • Ha, Man-Yeong;Lee, Dae-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.11
    • /
    • pp.3695-3705
    • /
    • 1996
  • We designed the hot wind tunnel to reproduce the conditions of utility boiler and carried out its performance test, in order to investigate the particulate two-phase flow behaviour, the fouling and heat transfer characteristics to the heat exchanger. The hot wind tunnel introduces the control system to control the temperature in the test section. The particle is injected into the hot gas stream. The fouling probe (cylindrical tube) is positioned normal to the particulate gas-particle two-phase flow and cooled by the air. The temperature of gas and cooling air, and temperature in the fouling probe are measured as a function of time, giving the local and averaged heat transfer and fouling factor. The shape of particulate deposition adhered to the fouling probe is also observed.