• 제목/요약/키워드: wind variation

검색결과 855건 처리시간 0.027초

도시화에 의한 야간 대기 냉각율 변화에 관한 연구 (Study on the Variation of Nighttime Cooling Rate Associated with Urbanization)

  • 이순환;박명희;김해동
    • 한국대기환경학회지
    • /
    • 제24권1호
    • /
    • pp.83-90
    • /
    • 2008
  • In order to clarify the urbanization intensity of Daegu Metropolitan and its characteristics, comparative study on the variation of the cooling rate of two different sites was carried out using observation data for 40 years by Korea Meteorological Adminstration. Daegu Metropolitan and Chupungnyung represent well urbanized and rural areas, respectively. In comparison with Chupungnyung, yearly mean temperature at Daegu Metropolitan increases rapidly and especially the differences of minimum temperature increasing rate during 40 years becomes greater. These differences of regional warming are caused by the different urbanization intensity between two sites. And the impact of anthropogenic heat due to urbanization should be stronger in nighttime than in daytime. Sensible heat advection by regional wind during 6 hours from 18 LST contributes to atmospheric cooling. For this reason wind speed is in proportion to cooling rate of atmosphere. However, wind after 24 LST induces the warm air advection and makes decrease the cooling rate in urban area. Although the cooling rates between Daegu Metropolitan and Chupungnyung are some different, the variation tendencies of cooling rate of two site are almost same. Therefore atmospheric cooling rate in nighttime tends to be associated with the intensity of wind speed.

Simulink에서 영구자석 동기형 풍력발전시스템의 전압변동에 대한 시뮬레이션 (Simulation for Voltage Variation of a Permanent Magnetic Synchronous Generator Wind Turbine Systems on Simulink)

  • 안해준;김현구;김홍우;장길수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.184.2-184.2
    • /
    • 2010
  • This study performs modelling and simulation of permanent magnetic synchronous generator wind turbine by using Matlab & Simulink. In simulation, change of wind velocity, change of load, and voltage decrease of infinite bus are performed. Through such simulation, different with wiring system that there is only existing load, this study can confirm problems and voltage changing characteristics, which can occur in distributed electric power that load and electric power is mixed and operated, especially, in interconnecting with wind power generation.

  • PDF

다리우스 풍력터빈의 부하변동에 따른 속도제어 (Speed Control of Darrieus Wind Turbine for Load-variation)

  • 오철수
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1995년도 추계학술발표회 초록집
    • /
    • pp.110-114
    • /
    • 1995
  • 다리우스 풍력터빈의 속도설정을 터빈이 만드는 토크와 발전기가 요구하는 토크의 Balance를 통해 찾아낼 수 있음을 검토하였다. 풍속에 따른 속도-토크곡선에서 일정v곡선과 일정P곡선이 만나는 점이 터빈의 동작점으로 되며 이는 stable 및 instable이 될 수도 있다. 또한 풍속과 출력이 각각 변할 때 이 동작점이 어떻게 이동되는가 하는 점을 제시하였다.

  • PDF

종관 바람 관측 자료를 이용한 북한 지역의 풍력자원 분석 (An Analysis of Wind Energy Resources using Synoptic Observational Data in North Korea)

  • 윤준희;서은경;박영산;김학성
    • 한국지구과학회지
    • /
    • 제31권3호
    • /
    • pp.225-233
    • /
    • 2010
  • 북한 지역의 27개 기상관측지점의 30년 바람 자료를 이용하여 고도 50 m에서의 풍력밀도를 분석하였다. 27개 지점의 연평균 풍력밀도는 58.6W/$m^2$로 1등급에 해당하는 풍력 자원이었다. 계절에 따른 평균 풍력밀도는 겨울보다 봄에 더 높았으며, 여름에는 봄의 50% 정도의 풍력밀도를 나타냈다. 풍력밀도의 일변화를 보면 거의 모든 관측 지점에서 오후에 비교적 높은 풍력밀도와 오전 3-6시 경에 낮은 풍력밀도를 보였으며, 일변화의 진폭은 봄에 가장 컸다. 특히 내륙 중심부인 개마고원 지역과 함경북도 동북부, 평안도 남부 해안, 황해도 해안 근처에서 비교적 높은 값을 나타냈다. 장진에서의 연평균 풍력밀도는 3등급인 151.2 W/$m^2$를 나타냈으며, 용연은 2등급인 102.4 W/$m^2$의 값을 보였다.

농형유도 풍력발전기의 성능개선을 위한 에너지저장장치의 동작특성 분석 (Operational Analysis of Energy Storage System to Improve Performance of Wind Power System with Induction Generator)

  • 이지헌;심명보;이혜연;한병문;양승철
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1138-1145
    • /
    • 2009
  • This paper presents an active and reactive power compensator for the wind power system with squirrel-cage induction generator. The output power of a wind power system changes irregularly according to the variation of wind speed. The developed system is able to continuously compensate the active and reactive power. The 3-phase inverter operates for the compensation of reactive power, while the DC/DC converter with super-capacitors operates for the compensation of active power. The operational feasibility of the proposed model was verified by simulations with PSCAD/EMTDC and the feasibility of hardware implementation was confirmed by experimental works with a scaled hardware model. The proposed compensator can be expected that developed system may be used to compensated the abrupt power variation due to sudden change of wind speed or sudden power-drop by tower effect. It can be also applied for the distributed generation and the Micro-Grid.

THERMOSPHERIC NEUTRAL WINDS WITHIN THE POLAR CAP IN RELATION TO SOLAR ACTIVITY

  • Won, Young-In;Killeen, T.L.;Niciejewski, R.J.
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제23권1호
    • /
    • pp.1-11
    • /
    • 1995
  • Thermospheric neutral winds and temperatures have been collected from the ground-based Fabry-Perot interferometer (FPI) at Thule Air Base ($76.5^{\circ}N{\;}69.0^{\circ}W$), Greenland since 1985. The thermospheric observations are obtained by determining the Doppler characteristics f the [OI] 6300 ${\AA}$ emissions of atomic oxygen. The FPI operates routinely during the winter season, with a limitation in the observation by the existence of clouds. For this study, data acquired from 1985 to 1991 were analyzed. The neutral wind measurements from these long-term measurements are used to investigate the influence of solar cycle variation on the high-latitude thermospheric dynamics. These data provide experimental results of the geomagnetic polar cap are also compared with the predictions of two semiempirical models : the vector spherical harmonics (VSH) model of Killeen et al. (1987) and the horizontal wind model (HWM) of Hedin et al. (1991). The experimental results show a good positive correlation between solar activity and thermospheric wind speed over the geomagnetic polar cap. The calculated correlation coefficient indicates that an increase of 100 in F10.7 index corresponds to an increase in wind speed of about 100 m/s. The model predictions reveal similar trends of wind speed variation as a function of solar activity, with the VSH and HWM models tending to overestimate and underestimate the wind speed, respectively.

  • PDF

Wind direction field under the influence of topography: part II: CFD investigations

  • Li, S.W.;Hu, Z.Z.;Tse, K.T.;Weerasuriya, A.U.
    • Wind and Structures
    • /
    • 제22권4호
    • /
    • pp.477-501
    • /
    • 2016
  • Though hilly topography influences both wind speeds and directions aloft, only the influence on wind speeds, i.e. the speed-up effect, has been thoroughly investigated. Due to the importance of a model showing the spatial variations of wind directions above hilly terrains, it is worthwhile to systematically assess the applicability and limitations of the model describing the influence of hilly topographies on wind directions. Based on wind-tunnel test results, a model, which describes the horizontal and vertical variations of the wind directions separately, has been proposed in a companion paper. CFD (Computational Fluid Dynamics) techniques were employed in the present paper to evaluate the applicability of the proposed model. From the investigation, it has been found that the model is acceptable for describing the vertical variation of wind directions by a shallow hill whose primary-to-secondary axis ratio (aspect ratio) is larger than 1. When the overall hill slope exceeds $20^{\circ}$, the proposed model should be used with caution. When the aspect ratio is less than 1, the proposed model is less accurate in predicting the spatial variation of wind directions in the wake zone in a separated flow. In addition, it has been found that local slope of a hill has significant impact on the applicability of the proposed model. Specifically, the proposed model is only applicable when local slope of a hill varies gradually from 0 (at the hill foot) to the maximum value (at the mid-slope point) and then to 0 (at the hill top).

선박간 이격거리에 따른 WIND SHIELDING EFFECT 검토 (The Study on Wind Shielding Effects According to Distance Between Two Ships)

  • 구명준;하문근;최재웅;배준홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1413-1417
    • /
    • 2004
  • The environmental elements which naturally occur can result in structural damages and operating faults of vessels under the navigation and mooring. These primary factors are considered as wind, waves and tide. In order to investigate wind shielding effects with respect to wind load conditions between two ships which face the wind directly or slantingly to the wind direction, this numerical simulation was preferred in terms of the variation of wind loads according to different distances, wind velocities and wind directions between two ships. The results were proved to be quite reasonable, comparing with experimental data from Danish Maritime Institute, and the report, "Environmental Conditions And Environmental Loads" published by Det Norske Veritas.

  • PDF

연계형 풍력발전설비(225[kV], AC 링크방식)가 전력계통의 전원 품질에 미치는 영향에 관한 연구 분석 (Research on the Effect of Interconnected Distributed Wind Power Generation(225[kV], AC Link Method) on Power Quality in System)

  • 나채동;박중신
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.147-153
    • /
    • 2010
  • 소규모 풍력 및 태양광설비가 기존의 배전계통에 연계되어 전압변동, 역률, 주파수, 고조파, 플리커 등의 전원품질 요소에 영향을 줄 것으로 우려하고 있다. 따라서 본 연구에서는 풍력발전설비(AC 링크방식)가 연계된 배전계통의 전력품질에 어떠한 영향을 줄 수 있는지에 대한 조사를 위하여 현재 운영 중에 있는 풍력발전설비의 전력변환장치 앞과 배전선로측 수용가 전원설비 2차측에 각각 전력품질 분석 장치를 설치하여 실측하고 풍력발전기가 가동과 정지 상태에서 배전선로측에 어떠한 영향을 주는지에 대하여 분석하였다. 분석결과 발전기가 가동 및 정지 시 전압변동이 0.34[%] 상승, 전류파형파고율 0.145 정도 상승, 위상차가 가동 중일 때 0.6[$^{\circ}$] 정도의 편차를 발생시켰다.

유체 역학 기반 도시 기류장 예측을 위한 입력 경계 바람장 특성 연구 (A Study of the Characteristics of Input Boundary Conditions for the Prediction of Urban Air Flow based on Fluid Dynamics)

  • 이태진;이순환;이화운
    • 한국환경과학회지
    • /
    • 제25권7호
    • /
    • pp.1017-1028
    • /
    • 2016
  • Wind information is one of the major inputs for the prediction of urban air flow using computational fluid dynamic (CFD) models. Therefore, the numerical characteristics of the wind data formed at their mother domains should be clarified to predict the urban air flow more precisely. In this study, the formation characteristics of the wind data in the Seoul region were used as the inlet wind information for a CFD based simulation and were analyzed using numerical weather prediction models for weather research and forecasting (WRF). Because air flow over the central part of the Korean peninsula is often controlled not only by synoptic scale westerly winds but also by the westerly sea breeze induced from the Yellow Sea, the westerly wind often dominates the entire Seoul region. Although simulations of wind speed and air temperature gave results that were slightly high and low, respectively, their temporal variation patterns agreed well with the observations. In the analysis of the vertical cross section, the variation of wind speed along the western boundary of Seoul is simpler in a large domain with the highest horizontal resolution as compared to a small domain with the same resolution. A strong convergence of the sea breeze due to precise topography leads to the simplification of the wind pattern. The same tendency was shown in the average vertical profiles of the wind speed. The difference in the simulated wind pattern of two different domains is greater during the night than in the daytime because of atmospheric stability and topographically induced mesoscale forcing.