A STUDY OF SKELETAL AND DENTAL CHANGES AFTER SURGICALLYASSISTED RAPID MAXILLARY EXPANSION (외과적 급속상악확장술 후 악골 및 치아의 위치 변화에 대한 연구)

  • Han, Chang-Hun;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.5
    • /
    • pp.390-398
    • /
    • 2005
  • Purpose: The aim of this study was to evaluate the skeletal and dentoalveolar dimensional changes following surgically-assisted rapid maxillary expansion (SARME). Patients & methods: Thirteen adults who had been treated by SARME for transverse maxillary deficiency from May 2000 to December 2003 were evaluated. The SARME procedure was the subtotal Le Fort I osteotomy combined with pterygomaxillary separation and anterior midpalatal osteotomy. Dental study casts and posteroanterior cephalometric radiographs were taken before operation, after removal of expansion device, and follow up period. Nasal cavity width, skeletal and dentoalveolar parameters were measured pre- and post-operatively. Results: 1. Mean nasal cavity width was increased 12%$(0{\sim}21%)$ of total expansion after retention. 2. Mean maxillary interdental width was increased 70%$(47{\sim}99%)$, 95%$(84{\sim}115%)$, and 77%$(57{\sim}94%)$ of total expansion in the canine, the first premolar, and the first molar region, respectively after retention. 3. Mean maxillary alveolar bone width was increased 66%$(42{\sim}84%)$, 74%$(42{\sim}94%)$, and 57%$(31{\sim}78%)$ of total expansion in the canine, the first premolar, and the first molar region, respectively after retention. 4. Mean palatal vault depth was decreased 1.3 mm ($0.5{\sim}2.0$ mm) after retention. 5. Mean interdental and alveolar bone width of the mandibular canine and intermolar width of mandible were slight increased as maxilla was expanded after retention. 6. There were statistical differences between preoperative and postoperative values of nasal cavity, all maxillary interdental and interalveolar widths, palatal vault depth, mandibular interdental and interalveolar width of canine(paired t-test, p<0.05). 7. The maxillary interdental and alveolar bone width were decreased approximately 25% of total expansion by relapse at follow up period. Conclusion: In conclusion, most amounts of maxillary interdental expansions were acquired with the expansion of the maxilla by SARME. For preventing the relapse, approximately 25% of the overexpansion was needed.

InGaAsP/InP Buried-Ridge Waveguide Laser with Improved Lateral Single-Mode Property

  • Oh, Su-Hwan;Kim, Ki-Soo;Kwon, Oh-Kee;Oh, Kwang-Ryong
    • ETRI Journal
    • /
    • v.30 no.3
    • /
    • pp.480-482
    • /
    • 2008
  • A novel InGaAsP/InP buried-ridge waveguide laser diode structure is proposed and demonstrated for use as a single-mode laser. The lateral mode of the proposed device can be controlled by adjusting the composition and thickness of the InGaAsP layer grown over the active region. Stable single-mode operation without kinks or beam-steering is achieved successfully with lateral and transverse in the junction plane even for the device with the ridge width of 9 ${\mu}m$ up to an injection current of 500 mA.

  • PDF

Variations of the hole injection efficiency with IGBT's collector structure (IGBT의 콜렉터 구조에 따른 홀 주입효율의 변화)

  • Choi, Byung-Sung;Chung, Sang-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1956-1958
    • /
    • 1999
  • The analysis of hole injection efficiency at the p+/n-drift layer junction in non-punchthrough IGBT structure is presented. This analysis takes into account carrier concentration variations by conductivity modulation. Good agreement between this analysis and simulation is found over a wide range of carrier lifetime and current density. The proposed analytical model of the hole injection efficiency as a function of collector width, collector concentration has been verified by device simulator, ATLAS.

  • PDF

Linewidth characterics of the PQR Lasers (광양자테 레이저의 선폭 특성)

  • 김종삼;김준연;반노익;임권섭;류유신;배중우;권오대
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.08a
    • /
    • pp.256-257
    • /
    • 2001
  • We measured the linewidth (FWHM) changes of the PQR laser against the diameter of the devices and the injection currents. We report the linewidth narrowing with increasing the PQR currents. A rough estimate of the line width behavior shows an inverse proportionality to the cavity length. The spectrum of $\frac{3}{4}$ circle cavity PQR laser is reported for the first time as well. The spectrum looks slightly different from that of the full circle device due to the structural distortion.

  • PDF

A White-LED Driver IC for Mobile Applications (모바일용 White-LED Driver IC)

  • Ko, Young-Seok;Park, Shi-Hong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.04b
    • /
    • pp.39-40
    • /
    • 2009
  • This paper presents a white-LED driver IC for a mobile application. It uses a high efficiency current mode boost converter method for a low voltage application. For a LED drive, it provides a PWM(Pulse Width Modulation) and analog dimming function. The device was designed and fabricated using 0.35um BCD process. The evaluated waveforms for an implemented IC show promising results.

  • PDF

Enhancement of the Magnetic Flux in Metglas/PZT-Magnetoelectric Integrated 2D Geomagnetic Device

  • Huong Giang, D.T.;Duc, P.A.;Ngoc, N.T.;Hien, N.T.;Duc, N.H.
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.308-315
    • /
    • 2012
  • Experimental investigations of the magnetization, magnetostriction and magnetoelectric (ME) effects were performed on sandwich - type Metglas/PZT/Metglas laminate composites. The results have been analyzed by taking into account the demagnetization contribution. The study has pointed out that the magnetic flux concentration is strongly improved in piezomagnetic laminates with a narrower width leading to a significant enhancement of the ME effects. The piezomagnetic laminates with the optimal area dimension were integrated to form a 2-D geomagnetic device, which simultaneously can precisely detect the strength as well as inclination of the earth's magnetic field. In this case, a magnetic field resolution of better than $10^{-4}$ Oe and an angle precision of ${\pm}0.1^{\circ}$ were determined. This simple and low-cost geomagnetic-field device is promising for various applications.

Adaptability test of the existing seeder in Foxtail millet & Sorghum (인력식 곡류 파종기를 활용한 조,수수 파종 적응성 구명)

  • Choi, Il-Su;Chung, Sun-Ok;Jun, Hyeon-Jong;Choi, Yong;Choi, Duck-Kyu;Kang, Tae-Gyoung;Hyun, Chang-Sik;Lee, Choung-Keun
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.4
    • /
    • pp.259-264
    • /
    • 2014
  • This research was conducted to find design factors of seed metering device for developing seeder. It can be sowed precisely 1~3 seeds of Foxtail millet & Sorghum. To obtain fundamental information for designing seed metering device, we conducted adaptability test of the existing seeder in Foxtail millet & Sorghum. Major findings were as followings. Except of Model-A which was adapted sorghum(by seeding metering cup of width 3.9mm and length 4.5mm), seeders which were used in experiment showed that high value of miss-planted rates and more than four-planted rates. So to enhance precision of seeding in Foxtail millet & Sorghum, existing seeders were considered necessary by some supplementation.

Experimental study on multi-level overtopping wave energy convertor under regular wave conditions

  • Liu, Zhen;Han, Zhi;Shi, Hongda;Yang, Wanchang
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.5
    • /
    • pp.651-659
    • /
    • 2018
  • A multi-level overtopping wave energy converter was designed according to the large tidal range and small wave heights in China. It consists of two reservoirs with sloping walls at different levels. The reservoirs share a common outflow duct and a low-head axial turbine. The experimental study was carried out in a laboratory wave-flume to investigate the overtopping performance of the device. The depth-gauges were used to measure the variation of the water level in the reservoirs. The data was processed to derive the time-averaged overtopping discharges. It was found that the lower reservoir can store wave waters at the low water level and break the waves which try to climb up to the upper reservoir. The upper sloping angle and the opening width of the lower reservoir both have significant effects on the overtopping discharges, which can provide more information to the design and optimization of this type of device.

Spectral-shape-controllable Chirped Fiber Bragg Grating with a Photomechanical Microactuator: Simulation and Experiment

  • Moon, Jong-Ju;Ko, Youngmin;Park, Su-Jeong;Ahn, Tae-Jung
    • Current Optics and Photonics
    • /
    • v.4 no.6
    • /
    • pp.477-482
    • /
    • 2020
  • Recently, one of the authors has been reported an optically tunable fiber Bragg grating (FBG) with a photomechanical polymer. It was based on a typical FBG with a downsized diameter of 60 ㎛, coated with azobenzene-containing polymer material. Azobenzene is a well-known reversibly photomechanical stretchable material under ultraviolet (UV) light. The small part of the functional-coating region on the FBG absorbed UV light, which pulled the UV-exposed part of the grating. It was selectable as tunable FBG or tunable chirped FBG, by adjusting the position of UV exposure on the grating. As proof of concept for the tunable FBG device, the characteristics just including UV-induced center-wavelength shift and spectral-width changes of the device were reported. In this paper, we report for the first time that the microactuator makes it possible to control the spectral shape of the FBG reflection, according to the specifications (shape and intensity) of the UV beam that reaches the FBG coated with the azobenzene polymer. In addition, we provide the group-delay profiles for the chirped FBG, so that the sign of its dispersion (normal or anomalous) can be tailored by simply selecting the moving direction of the UV light's displacement in the experiment.