• Title/Summary/Keyword: width in dimension > k

Search Result 235, Processing Time 0.025 seconds

The development of a propulsion system for MAGLEV vehicle (자기부상열차용 추진시스템의 개발)

  • Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.637-641
    • /
    • 1992
  • This paper presents a fundanental method to analyze and design a Single-sided Linear Induction Motor(SLIM) as a propulsion system for magnetic levitation vehicles of DAEJEON EXPO'93 in Korea. The performance characteristics of the designed SLIM are examinated by the thrust force, the normal force, the efficiency and the power factor according to the change of input frequency. The dimension of the SLIM is 1792mm long ${\times}$ 200mm width ${\times}$ 58mm high and the rated thrust is 1300 Newtons at the operating speed of 40 Km/h.

  • PDF

DENTAL CROWDING AND ITS RELATIONSHIP TO TOOTH SIZE AND ARCH DIMENSION IN KOREAN (한국인에서 치아 및 악궁의 크기와 총생의 관계)

  • Lee, Nan-Young;Hong, Sung-Su;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.510-521
    • /
    • 2006
  • This investigation was undertaken to examine the extent to which tooth size and arch dimension each contribute to dental crowding. The sample included 50 subjects with well aligned dentition (25 males, 25 females) and those of 40 subjects with gross dental crowding(20 males, 20 females). Plaster model and digital model made from alginate impression taken at the one visit. Tooth size, arch length, arch perimeter, intercanine width and intermolar width was measured on the plaster and digital models. The findings in this study lead to the following conclusions. 1. In maxilla, the mesiodistal diameters of lateral incisor and premolars of the crowded group were significantly larger than those of the normal occlusion group (P<0.05). 2. In mandible, the mesiodistal diameters of central incisor, canine and premolars of crowded group were significantly larger than those of the normal occlusion group (P<0.05). 3. In maxilla, arch perimeter and intermolar width of crowded group were significantly smaller than normal occlusion group but intercanine width of crowded group were larger than normal occlusion group (P<0.05). There was no significantly difference in arch length (P>0.05). 4. In mandible, arch perimeter of crowded group was smaller than normal occlusion group(P<0.05). There were no difference in arch length intermolar width and intercanine width (P>0.05) 5. In the analysis of correlation coefficients of arch length discrepancy with variables, arch perimeter, intermolar width and mesiodistal width of 2nd premolar showed positive correlations in maxilla. 6. There was a significant difference between tooth width measurements made by the 2 methods, with all the digital model measurement larger than plaster model measurements (P<0.05) : the magnitude of the differences does not appear to be clinically relevant. 7. In the analysis for reproducibility, the plaster model measurement was showed lower degree of correlation between 1st and 2nd measurement than digital model.

  • PDF

The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner - (3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 -)

  • Park, Sun-Mi;Nam, Yun-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.14 no.1
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

A STUDY ON THE MORPHOLOGY OF MANDIBULAR CONDYLE (MRI를 이용한 한국인 하악과두의 형태에 관한 연구)

  • Lee, Doo-Hee;Oh, Soon-Ho;Suh, Chang-Ho;Kim, Joon-Bae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.5
    • /
    • pp.423-427
    • /
    • 2001
  • Objective: This study was prepared to figure out a certain dimension and morphology of the condyle at the central, medial and lateral aspects on MR images of asymptomatic volunteers, which could be comparable with those of the TMD patients' condyle. Materials: Sixty TMJs from 30 asymptomatic volunteers(15 male, 15 female) who had no clinical symptoms and no disc displacement on sagital and coronal view of MRI were served as normal. Method: MR images were taken from the asymptomatic volunteers and the dimension of the anteroposterior length, mediolateral width, height, convexities were measured through the images on the sagittal and coronal sections of mandibular condyle. Then, these data were collected and analyzed. Result: The mean value of anteroposterior length was $8.00{\pm}1.21mm$ at central section and mediolateral length was $21.40{\pm}2.32mm$ on coronal view. The anterior condylar length at medial side was the shortest and the convexity of anterior slop at the lateral side was proved to be the flattest among 3 sections. There were little dimensional and morphological differences at sagittal sections, but the mediolateral width of condyle at coronal section was significantly different between male and female. Conclusion: In sagittal sections, the anterior condyle length was shortest at medial side and the convexity of anterior slop was flattest at lateral side, and there were little dimensional and morphologic differences between male and female. In coronal section, male's condyle was more wider and flatter than female's.

  • PDF

Fine Structures of Some Major Softwoods and Hardwoods by X-ray Diffraction Methods (X선회절법(線回折法)에 의한 주요(主要) 침·활엽수재의 미세구조(微細構造) 해석(解釋))

  • Lee, Won-Yong;Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.28-37
    • /
    • 1992
  • Fine structures of some Korean woods were investigated by X-ray diffraction methods. Relative crystallinity measured by the Segal's method and by the area method was $53{\pm}6%$ and $43{\pm}8%$ in softwoods, and $54{\pm}5%$ and $45{\pm}5%$ in hardwoods, respectively. The crystallite dimension in width was $3.11{\pm}0.45nm$ in softwoods and $3.22{\pm}0.25nm$ in hardwoods. In the longitudinal direction, the dimension was $12.79{\pm}0.89nm$ in softwoods and $12.60{\pm}0.72nm$ in hardwoods. The d-spacings of (200) in equatorial and (004) in meridional layers were about 0. 397 run and about. 0.260 nm, respectively. As a result, relative crystallinity, crystallite dimensions and d-spacings of (200) did not show any differences between the softwoods and hardwoods. The ratio of integrated intensities of (002) and (004), however, showed some differences between the softwoods and hardwoods. Namely, it was $0.101{\pm}0.027$ in softwoods and $0.138{\pm}0.037$ in hardwoods.

  • PDF

Change of arch dimension using two different expansion modalities in adults-MARPE and continuous archwire: a pilot study (임상가를 위한 특집 4 - 성인에서 미니스크류 보강형 비수술적 구개확장장치와 연속호선에 의한 악궁확장 효과 비교)

  • Koo, Yun-Jin;Choi, Tae-Hyun;Jang, Ji-Sung;Lee, Kee-Joon
    • The Journal of the Korean dental association
    • /
    • v.51 no.6
    • /
    • pp.330-336
    • /
    • 2013
  • Considering the high prevalence, transverse control in adult patients presenting relatively narrow maxillary width is a challenging issue. This study compared the pattern of arch expansion induced by either miniscrew-assisted rapid palatal expander (MARPE) or continuous archwire engaged on self-ligating brackets. Age-matched adults groups(N=15 each) were treated with respective appliance. In both groups, all intercanine, interpremolar, and intermolar widths increased, and significantly greater change was noted in the intermolar region. Buccal tipping was minimal in both groups. Subsequent arch length increase, lingual tipping of incisors and distal tipping of molars were also found in both groups. According to the results, it can be concluded that the MARPE induced generally more arch expansion, particularly in the intermolar width, indicating that the adults showing buccal crossbite of the molars may have to undergo expansion via MARPE prior to arch alignment using continuous archwire.

The Study on the embedded capacitor using thick film lithography (후막 리소그라피 공정을 이용한 내장형 캐패시터 개발에 관한 연구)

  • Yoo, Chan-Sei;Park, Seong-Dae;Park, Jong-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.342-345
    • /
    • 2002
  • As the size of chip components and module decreases, new patteming method for fine line and geometry is needed. So far, in LTCC(Low Temperature Cofired Ceramic) process, screen printing method has been used generally. But screen printing method has some disadvantages as follows. First, the geometry including line, vias, etc. smaller than $100{\mu}m$ can't be evaluated easily. Second, the patterned dimension is different from designed value, which makes distortion in charactersitics of not only chip components but also modules. Thick film lithography has advantages of thick film screen printing process, low cost and thin film process, fine line feasibility. Using this method, the line with $30{\mu}m$ width and the geometry with expected dimension can be evaluated. In this study, the fine line with $35{\mu}m$ line/space is formed and the embedded capacitor with very small tolerance is developed using thick film lithography.

  • PDF

A COMPARATIVE STUDY ON DENTAL ARCH DIMENSION OF HIGH SCHOOL FEMALES ACCORDING TO THE REGION OF RESIDENCE AND FACIAL TYPE (지역 및 안모형태에 따른 여고생의 치열궁 크기에 대한 비교)

  • Jang, Jae-Hong;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.24 no.4 s.47
    • /
    • pp.885-895
    • /
    • 1994
  • This study was performed to compare the dental arch dimensions of urban and rural high school females according to the region of residence and facial type. A model and cephalometric analysis was made from 48 urban and 48 rural high school females. The results of this study were obtained as follows : 1. Arch width in the urban group were similar to the rural group. 2. Lingual arch length at upper 1st premolar level in the urban group was larger than the rural group and lingual arch length at lower canine level in rural group was larger than the urban group. 3. Palatal height at canine level in the rural group was higher than the urban group. 4. Palatal heights at 2nd premolar and 1st molar level had correlation with the VERT index. In comparison of lingual arch dimensions according to Rickett's facial group, palatal heights at 2nd premolar and 1st molar level in dolichofacial group were lower than other groups.

  • PDF

Mandibular arch orthodontic treatment stability using passive self-ligating and conventional systems in adults: A randomized controlled trial

  • Rahman, Norma Ab;Wey, Mang Chek;Othman, Siti Adibah
    • The korean journal of orthodontics
    • /
    • v.47 no.1
    • /
    • pp.11-20
    • /
    • 2017
  • Objective: This randomized controlled trial aimed to compare the stability of mandibular arch orthodontic treatment outcomes between passive self-ligating and conventional systems during 6 months of retention. Methods: Forty-seven orthodontic patients with mild to moderate crowding malocclusions not requiring extraction were recruited based on inclusion criteria. Patients (mean age $21.58{\pm}2.94years$) were randomized into two groups to receive either passive self-ligating ($Damon^{(R)}$ 3MX, n = 23) or conventional system (Gemini MBT, n = 24) orthodontic treatment. Direct measurements of the final sample comprising 20 study models per group were performed using a digital caliper at the debonding stage, and 1 month, 3 months, and 6 months after debonding. Paired t-test, independent t-test, and non-parametric test were used for statistical analysis. Results: A significant increase (p < 0.01) in incisor irregularity was observed in both self-ligating and conventional system groups. A significant reduction (p < 0.01) in second interpremolar width was observed in both groups. Mandibular arch length decreased significantly (p = 0.001) in the conventional system group but not in the self-ligating system group. A similar pattern of stability was observed for intercanine width, first interpremolar width, intermolar width, and arch depth throughout the 6-month retention period after debonding. Comparison of incisor irregularity and arch dimension changes between self-ligating system and conventional system groups during the 6 months were non-significant. Conclusions: The stability of treatment outcomes for mild to moderate crowding malocclusions was similar between the self-ligating system and conventional system during the first 6 months of retention.

Dynamics of Transverse Magnetic Domain Walls in Rectangular-shape Thin-film Nanowires Studied by Micromagnetic Simulations

  • Lee, Jun-Young;Choi, Sang-Kook;Kim, Sang-Koog
    • Journal of Magnetics
    • /
    • v.11 no.2
    • /
    • pp.74-76
    • /
    • 2006
  • Dynamic behaviors of transverse domain walls (TDWs) in rectangular shaped thin-film magnetic nanowires with different widths under applied magnetic fields less than the Walker field were studied by micromagnetic simulations. It was found that the velocity of stable TDWs in the viscous region increases from 147 to 419 m/s and their mass decreases from $6.24{\times}10^{-23}\;to\;2.70{\times}10^{-23}kg$ with increasing strength of the applied magnetic field ranging from 5 to 20 Oe for the nanowire with a dimension of 10 nm in thickness and $5{\mu}m$ in length, and 50 nm in width. With increasing the width of nanowires from 50 to 125 nm at a specific field strength of 5 Oe, the TDW's velocity also increases from 147 to 246 m/s and its mass decreases from $6.24{\times}10^{-23}\;to\;5.91{\times}10^{-23}kg$.