• Title/Summary/Keyword: width control

Search Result 2,405, Processing Time 0.03 seconds

A New Control Strategy for a Three-Phase PWM Current-Source Rectifier in the Stationary Frame

  • Guo, Qiang;Liu, Heping;Zhang, Yi
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.994-1005
    • /
    • 2015
  • This paper presents a novel power control strategy for PWM current-source rectifiers (CSRs) in the stationary frame based on the instantaneous power theory. In the proposed control strategy, a virtual resistance based on the capacitor voltage feedback is used to realize the active damping. In addition, the proportional resonant (PR) controller under the two-phase stationary coordinate is designed to track the ac reference current and to avoid the strong coupling brought about by the coordinate transformation. The limitations on improving steady-state performance of the PR controller is investigated and mitigated using a cascaded lead-lag compensator. In the z-domain, a straightforward procedure is developed to analyze and design the control-loop with the help of MATLAB/SISO software tools. In addition, robustness against parameter variations is analyzed. Finally, simulation and experimental results verify the proposed control scheme and design method.

The Power Amplifier Control Design of eLoran Transmitter

  • Son, Pyo-Woong;Seo, Kiyeol;Fang, Tae Hyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.3
    • /
    • pp.229-234
    • /
    • 2021
  • In this paper, a study was conducted on the power amplifier control required to design an eLoran transmitter system using a low-height antenna. The eLoran transmitter developed during the eLoran technology development project conducted in Korea used a small 35 m antenna due to the difficulty of securing a site for antenna installation. This antenna height is very low compared to the height of 750 m which is required for eLoran 100 kHz signal transmission without any radiation loss. In the case of using such a small antenna, not only the radiation efficiency of the transmission is lowered, but also the power module control must be performed more precisely in order to transmit the eLoran standard signal. The equivalent RLC circuit of the transmitter system was implemented and transient analysis was conducted to derive the input required voltage for satisfying the output requirement. The voltage waveform was also generated by the RLC circuit analysis to generate the eLoran signal. Furthermore, we suggest power width modulation method to control eLoran power amplifier module more sophisticatedly.

An Evaluation of Various Synthetic Generations and Polycross Progenies in Winter Active Tall Fescue (Festuca arundinacea Schreb) - I. Summer Forage Phase (동기생육형(冬期生育型) 톨페스큐의 합성품종세대(合成品種世代)와 다계교배(多系交配) 후대검정(後代檢定)에 관(關)한 연구(硏究))

  • Kim, Dal Ung
    • Korean Journal of Agricultural Science
    • /
    • v.2 no.2
    • /
    • pp.341-356
    • /
    • 1975
  • This study was carried out to evaluate three winter active synthetic varieties in a succeeding generations of improvement and polycross progenies of seven genotypes selected at the cool and wet climate of the Western Oregon, in their performance of the polycross progeny test comparing with a control variety, high yielding 'Fawn', at Daejon, Korea. Various plant and leaf characteristics, especially related to photosynthesis, and forage production during the first summer after the establishment were examined. The important conclusions of this study are summarized as follows: 1. The differences of leaf fresh weight among groups and control exhibit genetic differences. The a verage of leaf fresh weight of polycross progeny group was the heaviest and those of winter active synthetic varieties in the succeeding generations of improvement was heavier than variety 'fawn'. Within polycross progeny group the genotypes exhibit genetic differences for leaf dry weight. 2. The leaf area exhibited genetic differences among groups and control. The average of winter active synthetic varieties in a succeeding generation was larger than variety 'Fawn'. Those oi the polycross progeny group was the largest among groups and control. 3. Differences of specific leaf weight(S. L. W.) among and within varieties, genotypes and control were not significant. Further investigation in this respect is necessary through the study of the diurnal change in S. L. W. 4. Differences of leaf width among groups and control exhibited genetic differences. The average leaf width of winter active varieties was larger than those of 'Fawn' variety. And those of polycross progenies of genotypes was the largest. 5. Plant height of 'fawn' variety in the first measurement was higher than those of winter active tall fescue varieties and genotypes. The deviation in plant height among polyeross progenies of seven genotypes gave a great deviation. The regrowth ability of plant height was not different suggesting that this characteristics was about the same among and within groups and control. 6. Plant width, spreading ability, improved through the succeeding generations of the improvement of the winter active synthetic varieties for the first measurement. Differences of plant width at the second measurement among genotypes within polycross progeny group were big enough to show the genetic difference. 7. Tiller number of the winter active synthetic varieties and the average of genotypes in polycross progeny was more than those of the control 'Fawn' in the first measurement. On the second measurement, the differences of tiller number appeared among three synthetic varieties indicating improvement, and there were genetic differences among seven genotypes in polycross progeny test. 8. Forage yield on the first cutting showed a considerble improvement of forage yield in the more advanced generation of synthetic varieties and genetic differences among seven genotypes in the polycross progeny test. The average of polycross progeny group was higher than those of the control or three winter active varieties. It was suggested that we could make a further improvement for the forage yield. 9. The regrowth ability of these winter active varieties and genotypes was about the same capacity at least on the measurement of the regrowth in forage yield and plant height during summer. 10. On the whole, the averages of the polycross progeny group was in the highest value and those of synthetic varieties were higher than the control variety, 'Fawn', for the most characteristics except S. L. W. and the plant height on the first measurement even though the differences were not always significant. And there were genetic differences among seven gentypes in their performance of the polycross progeny. 11. Although it was not always sgnificant, the most advanced winter active variety, '1002', had in the highest value for all plant characteristics and forage yield measurements than the other two varieties, '1001'. 12. The results of the association study among various characteristics were quite agreeable and would be useful in the selection of desirable genotypes for the development of a better variety.

  • PDF

Effect of Temperature, Glasshouse Forcing Date and GA3 on the Growth and Flowering of Hydrangea macrophylla Ser. (온도, 입실시기 및 GA3 처리가 수국의 생육 및 개화에 미치는 영향)

  • Lee, Hee Doo;Kim, Si Dong;Kim, Ju Hyoung;Lee, Jong Won;Kim, Tae Jung;Lee, Cheol Hee
    • FLOWER RESEARCH JOURNAL
    • /
    • v.16 no.4
    • /
    • pp.260-265
    • /
    • 2008
  • Studies were carried out to elucidate the effect of temperature, glasshouse forcing date and $GA_3$ on the growth and flowering of pot Hydrangea macrophylla Ser. The plant height was elongated in the $5^{\circ}C$ treatments as 38 cm compared with $20^{\circ}C$ treatment as 6.7 cm, and stem length showed the similar results. The leaf length and width was broadened in the lower temperature, and stem diameter showed the same tendency. The first flowering date in the $15^{\circ}C$ and $20^{\circ}C$ treatment shortened markedly than $5^{\circ}C$ treatment. Days to flowering date of $5^{\circ}C$ was 161 day, while it shortened as 88 day in the $15^{\circ}C$ treatment. The flowering rate was 75.8~90.7% in the temperature. The plant height was elongated in the late glasshouse forcing date, and the leaf length and width showed the similar tendency. The plant height increased in the higher concentration of $GA_3$ compared to the control, and leaf length and width showed the similar results. The first flowering day was advanced by 7 days in the $GA_3$ $50mg{\cdot}L^{-1}$ treatment which had been transferred to greenhouse on Dec. 30 compared with the control of which first flowering day was March 17, and the days to first flowering was conspicuously shortened in the late glasshouse forcing treatment. The width of flower cluster was increased in the $GA_3$ at Dec. 30 glasshouse forcing treatment. The flowering rate was markedly decreased as 62.3% in the control of Nov. 15 treatment, but was increased as 97.9% of $GA_3$ $50mg{\cdot}L^{-1}$ of Jan. 15 treatment.

Verification of Control Algorithm for Removing Oil Contaminant Factor from Proportional Pressure Control Valve (전자식 비례 압력제어밸브 내 오일 오염 입자 제거 제어 알고리즘 검증)

  • Cheon, Su Hwan;Park, Jin Kam;Jang, Kyoung Je;Sim, Sung Bo;Jang, Min Ho;Lee, Jin Woong
    • Journal of Drive and Control
    • /
    • v.18 no.4
    • /
    • pp.1-8
    • /
    • 2021
  • An electro proportional pressure control valve is mainly used to control the clutch of an agricultural tractor's automatic transmission. During transmission, the operating, hydraulic oil is mix with many kinds of contaminants. The contaminants can be trapped between the valve body and spool of the proportional pressure control valve leading to abnormal operating conditions and finally critical damage to the transmission hydraulic system. The present study aimed to verify the valve control algorithm as a basic study of developing control logic that removes contaminants between the spool and the body of the proportional pressure control valve. To develop the algorithm, MATLAB/SIMULINK was used. PWM method was used to control the applied solenoid coil current. The effectiveness of the algorithm was verified by comparing the actual pressure of the normal valve with the actual pressure of the abnormal valve. Based on the present study findings, when the algorithm was applied, the response of the valve pressure according to the current became stable and oil contaminated particles were removed. In the future study, the control algorithm will be optimized for the stability of the proportional pressure reducing valve, and it will be verified in consideration with the driving of the clutch.

A Study of the Flow Phenomenon of Water in a Channel with Flat Plate Obstruction Geometry at the Entry

  • Khan, M.M.K.;Kabir, M.A.;Bhuiyan, M.A.
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.879-887
    • /
    • 2003
  • The flow in a parallel walled test channel, when obstructed with a geometry at the entrance, can be forward, reverse and stagnant depending on the position of the obstruction. This interesting flow phenomenon has potential benefit in the control of energy and various flows in the process industry In this experiment, the flat plate obstruction geometry was used as an obstruction at the entry of the test channel. The parameters that influence the flow inside and around the test channel were the gap (g) between the test channel and the obstruction geometry, the length (L) of the test channel and the Reynolds number (Re). The effect of the gap to channel width ratio (g/w) on the magnitude of the velocity ratio (V$\_$i/ / V$\_$o/ : velocity inside/ velocity outside the test channel) was investigated for a range of Reynolds numbers. The maximum reverse flow observed was nearly 20% to 60% of the outside velocity for Reynolds number ranging from 1000 to 9000 at g/w ratio of 1.5. The maximum forward velocity inside the test channel was found 80% of the outside velocity at higher g/w ratio of 8. The effect of the test channel length on the velocity ratio was investigated for different g/w ratios and a fixed Reynolds number of 4000. The influence of the Reynolds number on the velocity ratio is also discussed and presented for different gap to width ratio (g/w). The flow visualisation photographs showing fluid motion inside and around the test channel are also presented and discussed.

Investigation of flowfield characteristics of a square prism having a front triangular prism by PIV (PIV에 의한 정면에 삼각주를 가진 정방형주 주위의 유동장 특성분석)

  • Ro, Ki-Deok;Kim, Jae-Dong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.205-209
    • /
    • 2016
  • The flowfield characteristics of a square prism having a small triangular prism at the upstream side were investigated by visualizing the flow field using PIV. The ratio of the width of the triangular prism to that of the square prism and the gap ratios between the square and triangular prisms were selected as the experimental parameters. The results are summarized as follows. The Strouhal number measured on the wake side of the square prism, which had the same characteristics as the drag reduction rate, increased, and then decreased with the gap ratio for the same width ratio. For a square prism having a small triangular prism, the stagnation regions were represented at the upstream and downstream sides of the square prism. The size of the stagnation region increased with the width ratio at the upstream side of the square prism, and decreased at the downstream side.

Analysis of Kinematics and Kinetics According to Skill Level and Sex in Double-under Jump Rope Technique

  • Kim, Dae Young;Jang, Kyeong Hui;Lee, Myeoung Gon;Son, Min Ji;Kim, You Kyung;Kim, Jin Hee;Youm, Chang Hong
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.3
    • /
    • pp.171-179
    • /
    • 2017
  • Objective: The purpose of this study was to perform a kinematic and kinetic analysis of double-under jump rope technique according to skill level and sex. Method: Participants comprised a skilled group of 16 (9 males, 7 females), and an unskilled group of 16 with 6 months or less of experience (9 males, 7 females). Five consecutive double-under successes were regarded as 1 trial, and all participants were asked to complete 3 successful trials. The data for these 3 trials were averaged and analyzed after collecting the stable third jump in each trial. The variables used in the analysis included phase duration, total duration, flight time, vertical toe height, stance width, vertical center of mass displacement, and right lower limb ankle, knee, and hip joint angles in the sagittal plane during all events. Results: The skilled group had a shorter phase and total duration and a shorter flight time than the unskilled group. The vertical center of mass displacement and ankle dorsiflexion angle were significantly smaller in the skilled group. The male group had a shorter phase duration than the female group. The vertical toe height was greater, the stance width was smaller, and the ankle and hip flexion angles were smaller in the male group. Conclusion: Variables that can be used to distinguish between skill levels are phase and total duration, flight time, vertical center of mass displacement, and ankle dorsiflexion angle. Differences between sexes in double-under jump rope technique may be related to lower limb flexion angle control.

Morphological Responses of Korean Native Plant Hosta longipes to Heavy Metals Cd, Pb, and Zn (중금속(카드늄, 납, 아연)처리에 따른 자생 비비추(Hosta longipes)의 형태적 반응)

  • Kang, Kwang-Cheol;Ju, Jin-Hee
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1583-1590
    • /
    • 2015
  • The aim of this study was to examine the morphological responses of Hosta longipes, an ornamental plants for heavy metal contaminated soils in urban landscaping, to heavy metals Cd, Pb, and Zn. Plants were grown in artificial soil amended with Cd, Pb, and Zn at concentation of 0, 100, 250, and 500 mg/kg. Plant height, leaf length, leaf width, total leaf number, deaf leaf number, new leaf number, chlorophyll contents, and ornamental value were monitored from May to August. At 4 months after planting, the survival and morphological responses of H. longipes grown in soil amended with Cd at concentrations ${\geq}100mg/kg$ were severely affected compared to those grown in the control soil. Relative leaf length rate and relative leaf width rate were significantly decreased when the concentration of Pb was increased. Total leaf number, chlorophyll contents, and ornamental value were the lowest value in plants grown in soil amended with Pb at level of 500 mg/kg. Relative leaf length rate and relative leaf width rate, total leaf number, dead leaf number, new leaf number, and ornamental values had a tendency of decrease when plants were grown in soils amended with Zn. However, no significant difference was found among treatments except for plants were grown in soils amended with 500 mg/kg Zn. Therefore, Hosta longipes might be useful for phytoremediation of Zn contaminated sites as herbaceous ornamental plants.

Experimental study on transmission and stability of submerged breakwater (잠제의 전달율과 안정성에 관한 실험적 연구)

  • Kim, Yong-Woo;Yoon, Han-Sam;Kim, Hong-Jin;Ryu, Cheong-Ro;Sohn, Byung-Kyu
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.213-219
    • /
    • 2003
  • As the 2-D hydraulic experimental results for the submerged rubble-mound structure, we have concerned with their stability/function characteristics of structures by the effects of wave force, scour/deposition at the toe and wave transmission ratio at the lee-side sea. And as to investigate the variation characteristics of wave transmission ratio which depended to a geometrical structure of the submerged breakwater profiles, the critical conditions for the depth of submergence and crest width obviously presented. In summary, there results lead us to the conclusions that the wave control capabilities of submerged breakwaters by the variation of the submergence depth is high about 4 time degrees at the efficiency than the that of crest width. The destruction of covering block at the crest generated at the region which located between maximum damage curve, it maximum damage/failure station from the toe of the structure were 0.2L. As the wave transmission coefficient and the slope of the structure increase, the damage/failure ratio and the maximum scour depth at the toe was extended, respectively. When maximum scour depth happened. The destruction of covering block which located at the toe generated at the front slope destruction. Finally, it was found from the results that the optimization of structure may be obtained by the efficiently decision of the submergence depth and crest width in the permissible range of wave transmission ratio.

  • PDF