• 제목/요약/키워드: width control

Search Result 2,405, Processing Time 0.033 seconds

Optimal Design of VCO Using Spiral Inductor (나선형 인덕터를 이용한 VCO 최적설계)

  • Kim, Yeong-Seok;Park, Jong-Uk;Kim, Chi-Won;Bae, Gi-Seong;Kim, Nam-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.5
    • /
    • pp.8-15
    • /
    • 2002
  • We optimally designed the VCO(voltage-controlled oscillator) with spiral inductor using the MOSIS HP 0.5${\mu}{\textrm}{m}$ CMOS process. With the developed SPICE model of spiral inductor, the quality factor of spiral inductor was maximized at the operating frequency by varying the layout parameters, e.g., metal width, number of turns, radius, space of the metal lines. For the operation frequency of 2㎓, the inductance of about 3nH, and the MOSIS HP 0.5 CMOS process with the metal thickness of 0.8${\mu}{\textrm}{m}$, oxide thickness of 3${\mu}{\textrm}{m}$, the optimal width of metal lines is about 20${\mu}{\textrm}{m}$ for the maximum Quality factor. With the optimized spiral inductor, the VCO with LC tuning tank was designed, fabricated and measured. The measurements were peformed on-wafer using the HP8593E spectrum analyzer. The oscillation frequency was about 1.610Hz, the frequency variation of 250MHz(15%) with control voltage of 0V - 2V, and the phase noise of -108.4㏈c(@600KHz) from output spectrum.

Effects of [D-$Pen^2$, D-$Pen^5$]-enkephalin on the Neuronal Activity of Medial Vestibular Nuclear Neurons

  • Jang, Su-Jeong;Jeong, Han-Seong;Park, Jong-Seong
    • Biomedical Science Letters
    • /
    • v.15 no.3
    • /
    • pp.199-205
    • /
    • 2009
  • This study was designed to investigate direct effects of [D-$Pen^2$, D-$Pen^5$]-enkephalin, a $\delta$-opioid receptor agonist on the neuronal activity of medial vestibular nuclear (MVN) neurons by whole-cell configuration patch clamp experiments. The spike frequency of MVN neuron was increased to $9.50{\pm}0.55$ (P<0.05) and $10.56{\pm}0.66$ (P<0.05) by 5 and $10{\mu}M$ [D-$Pen^2$, D-$Pen^5$]-enkephalin from the control level of $8.05{\pm}0.55$ spikes/sec, respectively (n=18). The resting membrane potential of the neurons was increased to $-37.86{\pm}0.92$ and $-36.97{\pm}0.97$ (P<0.05) from $-38.74{\pm}1.13\;mV$ by 5 and $10{\mu}M$ [D-$Pen^2$, D-$Pen^5$]-enkephalin, respectively. The amplitude of afterhyperpolarization was decreased to $23.78{\pm}0.65$ and $21.67{\pm}0.89$ (P<0.05) from $23.73{\pm}0.53\;mV$ by 5 and $10{\mu}M$ [D-$Pen^2$, D-$Pen^5$]-enkephalin, respectively. The spike width was changed to $2.22{\pm}0.08$ and $2.24{\pm}0.07$ from $2.20{\pm}0.08\;mV$ by 5 and $10{\mu}M$ [D-$Pen^2$, D-$Pen^5$]-enkephalin, respectively. After pretreatment of naltrindole, a highly selective 8-opioid receptor antagonist, [D-$Pen^2$, D-$Pen^5$]-enkephalin did not change firing rate, resting membrane potential, afterhyperpolarization amplitude, and spike width of MVN neurons. The above experimental results suggest that [D-$Pen^2$, D-$Pen^5$]-enkephalin increases the neuronal activity of MVN neurons via inhibition of calcium-dependent potassium currents underlying the afterhyperpolarization.

  • PDF

The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom (N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과)

  • Kim, Yon-Min;Shim, Jae-Goo;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.221-225
    • /
    • 2017
  • To evaluate the performance of ultrasound imaging system, we investigated the change of spatial resolution according to changing sonic velocity change parameter provided by ultrasound equipment. Ultrasound phantom images were obtained using a 3.0 ~ 5.0 MHz convex transducer in an ultrasound diagnostic device used at a medical institution located at Iksan. N-365 multi-purpose ultrasound phantom was used to measure longitudinal distance measurement accuracy and longitudinal and transverse resolution. In the same manner, the sonic velocity of the ultrasound equipment was changed from 1580 m/sec to 1400 m/sec in six steps, and the full width at half maximum(FWHM) was measured using the image J program to determine whether the measured values were different. As a result, lateral resolution was measured from 1.91 mm to 5.3 mm according to the speed change, and the smallest FWHM was 1.91 mm at 1420 m/sec. The axial resolution was measured from 1.03 mm to 1.14 mm according to the speed change, and the smallest FWHM was 1.03 mm at 1400 m/sec. The slower the sound velocity of the ultrasound equipment, the shorter the length of longitudinal measurement.

Hidden Object Detection System using Parametric Array (파라메트릭 배열을 이용한 은폐 물체 탐지 시스템)

  • Lee, Kibae;Lee, Jaeil;Bae, Jinho;Lee, Chong Hyun;Cho, Jung Hong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.3
    • /
    • pp.78-86
    • /
    • 2017
  • In this paper, we propose hidden object detection system using parametric array based on acoustic signal that is harmless to human body. A transmit signal of the proposed detection system uses a high directive chirp signal generated from parametric array phenomenon, which uses technique to improve a signal to noise (SNR) of a received signal and a distance resolution trough the dechirp processing. The transmit sensor array is constructed as $8{\times}2$ and has a horizontal beam width of $7^{\circ}$ and vertical beam width of $26^{\circ}$. To verify the detection and visualization of the proposed system, a 2-axis driving control system based on linear stage was constructed, and A-scan, B-scan, and C-scan experiments was addressed for hidden object. From experimental results, we detected and visualized the hidden bronze plate and pipe by cloth and the visualized shapes was confirmed. Especially, the obtained errors was $0.015m^2$ for bronze plate, and $0.046m^2$ for pipe.

Lead (Pb) Concentrations in Soil, Air and Fruits of Sweet Orange (Citrus sinensis L. Osbeck) in Selected Landuse in Port Harcourt Metropolis, Rivers State, Nigeria

  • Eludoyin, Olatunde Sunday;Odimegwu, Vitus Chinonso
    • Journal of Forest and Environmental Science
    • /
    • v.34 no.4
    • /
    • pp.284-292
    • /
    • 2018
  • The study investigated the concentrations of Pb in soil, air and fruit of C. sinensis in selected landuse types in Port Harcourt Metropolis, Rivers State, Nigeria. Five fruits of C. sinensis were collected randomly in residential, commercial, industrial and natural forest (control). The weight, length and width of the C. sinensis fruits were measured. A total of three soil samples were collected around the C. sinensis trees where the fruits were collected into well labeled polythene bags and thereafter taken to laboratory for analysis. Pb concentrations in C. sinensis and soil samples were analysed using atomic absorption spectrophotometer (AAS). The concentration of Pb in the air was measured for 14 days using Aeroquel 500. The significant relationship between Pb concentration in the C. sinensis fruits, soil and air was determined using Spearman's rank correlation. Findings showed that the mean weight and width of C. sinensis fruits were highest in the residential landuse while the mean length of C. sinensis fruits was highest in the industrial landuse. However, the mean Pb concentration in the C. sinensis fruit was highest in the industrial landuse ($0.46{\pm}0.15mg\;kg^{-1}$), commercial landuse ($0.33{\pm}0.09mg\;kg^{-1}$) and the least was found in the natural forest ($0.25{\pm}0.06mg\;kg^{-1}$). The mean Pb concentration in the soil was highest in the industrial landuse ($0.177{\pm}0.16mg\;kg^{-1}$) and commercial landuse ($0.121{\pm}0.10mg\;kg^{-1}$). However, the mean Pb concentration in the air was highest in the industrial landuse ($0.85{\pm}0.09mg\;kg^{-1}$) and followed by commercial landuse ($0.30{\pm}0.17mg\;kg^{-1}$). The correlations between the Pb concentration in the C. sinensis fruit and soil (r=0.768, p<0.05) and air (r=0.642, p<0.05) were significant. The study concluded that the Pb concentration in the C. sinensis fruits was higher than the WHO standard; hence people should be discouraged to consume them, especially those from the industrial and commercial areas.

Changes in Hematological and Serum Biochemical Parameters After Single Dose of Recombinant Human Erythropoietin (HM10760) in Male Cynomolgus Monkeys (게잡이 원숭이에 있어 rHuEPO(HM10760)의 단회 투여 후 혈액학 및 혈액생화학적 변화)

  • Kim Choong-Yong;Lee Hyun-Sook;Lee Pil-Soo;Ha Chang-Su;Kwon Se-Chang;Lee Gwan-Sun;Song Chang-Woo;Han Sang-Seop
    • Toxicological Research
    • /
    • v.22 no.1
    • /
    • pp.61-67
    • /
    • 2006
  • Changes in hematology and serum biochemistry after treatment of recombinant human erythropoietin (rHuEPO, HM10760) were screened in 4 male cynomolgus monkeys (Macaca fascicularis). Four monkeys, composed of a treatment group of HM10760 and a positive control group of $Aranesp^(R}$, were subcutaneously administered at same dose of $100{\mu}g/kg$. Both groups did not show any change in body weights and food consumption for 4 weeks compared with those of pretreatment. Both groups did not show any change in total leukocyte count (WBC) and platelet count, while both groups showed increased platelet distribution width (PDW) percentage in HM10760 group during a period from day 5 to day 59 and in $Aranesp^(R}$ group during a period from day 9 to day 26. Both groups showed increases in red blood cells (RBC), hemoglobin (HGB), and hematocrit (HCT) approximately 10 days after treatment compared with those of pretreatment (day 0). The increased levels of RBC, HGB, and HCT were much higher in HM10760 than in $Aranesp^(R}$ by the increases of $3.2%{\sim}12.5%$ for RBC, $3.8%{\sim}17.1%$ for HCT, and $1.85%{\sim}11%$ for HGB. Both groups showed increases in red cells distribution width (RDW) and reticulocyte (RET) compared with those of pretreatment, showing the highest peak from day 9. The increased level of RET lasted up to day 14 in $Aranesp^(R}$ group, while it lasted up to day 23 in HM10760 group. The increased level of RDW lasted up to day 59, it was much higher in HM10760 by the increase of $10.1%{\sim}17.6%$ than in $Aranesp^(R}$ group. In serum biochemistry, both groups showed a decrease in chloride level compared with those of pretreatment. These findings indicated that HM10760 increased RBC, HGB, HCT, RDW, and RET compared with those of pretreatment, and the increased levels were much higher in HM10760 than in $Aranesp^(R}$.

Effect of Day-length Extension Treatment Using LED on Growth and Flowering of Freesia hybrid 'Yvonne' (LED를 이용한 장일 처리가 프리지아(Freesia hybrida) '이본느'의 생육 및 개화에 미치는 영향)

  • Lee, Jin-Jae;Hwang, Ji-Hye
    • Horticultural Science & Technology
    • /
    • v.32 no.6
    • /
    • pp.794-802
    • /
    • 2014
  • The aim of this study was to determine the effect of day-length extension treatment using LED lighting (blue, green, red, or 3 mixed) on vegetative growth and flowering of freesia 'Yvonne', in comparison to that using glow lamps and metal halide lamps. Lighting treatments were imposed from 5 PM to 8 PM for 150 days from after flower bud differentiation to flowering end. For the period from leaf emergence to floral bud formation, no light source affected plant height but the number of leaves was decreased by the metal halide lamp. The highest SPAD value in the flower bud developing period occurred in the metal halide lamp treatment. The time of flowering was advanced by blue or green LED treatment compared to the no lighting control. The green LED lighting advanced flowering by 6 and 8 days compared to no lighting and metal halide lamp treatment, respectively. The blooming period tended to be shortened by the red LED treatment. As for the flower characteristics of 'Yvonne', floret length and width, and the weight of cut flowers were highest in the metal halide lamp treatment. Red LED decreased corm width and weight of 'Yvonne' while glow lamp decreased height and weight. Starch contents in corm were not influenced by the lighting source. Our results indicate that the green LED lighting advanced the time of flowering and the metal halide lamp was good for cut-flower quality.

A Study on the Utility Interactive Photovoltaic System Using a Chopper and PWM Voltage Source Inverter for Air Conditioner a Clinic room (병실 냉.난방을 위한 초퍼와 PWM 전압형 인버터를 이용한 계통 연계형 태양광 발전시스템에 관한 연구)

  • Hwang, L.H.;Na, S.K.
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.360-369
    • /
    • 2008
  • The solar cells should be operated at the maximum power point because its output characteristics were greatly fluctuated on the variation of insolation, temperature and load. It is necessary to install an inverter among electric power converts by means of the output power of solar cell is DC. The inverter is operated supply a sinusoidal current and voltage to the load and the interactive utility line. In this paper, the proposes a photovoltaic system is designed with a step up chopper and single phase PWM voltage source inverter. Synchronous signal and control signal was processed by one-chip microprocessor for stable modulation. The step up chopper is operated in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power point of solar cell without any influence on the variation of insolation and temperature for solar cell has typical dropping character. The single phase PWM voltage source inverter is consists of complex type of electric power converter to compensate for the defect, that is, solar cell cannot be develop continuously by connecting with the source of electric power for ordinary using. It can be cause the efect of saving electric power, from 10 to 20%. The single phase PWM voltage source inverter operates in situation, that its output voltage is in same phase with the utility voltage. The inverter are supplies an ac power with high factor and low level of harmonics to the load and the utility power system.

Flow Rate Changes in the Heterogeneous Rectangular Microchannels with Different Hydrophilicity for the PDMS Bottom Surface (PDMS 표면특성에 따른 비균일계 마이크로채널의 유속 변화)

  • Noh, Soon-Young;Lee, Hyo-Song;Kim, Ki-Ho;Choi, Jae-Ho;Yu, Jae-Keun;Yoon, Soo-Kyung;Rhee, Young-Woo
    • Clean Technology
    • /
    • v.13 no.3
    • /
    • pp.195-200
    • /
    • 2007
  • This study investigated the flow rate changes of the heterogeneous rectangular microchannels which have different hydrophilic property on the bottom surface. The heterogeneous rectangular microchannel has three native PDMS (poly-dimethyl siloxane) surfaces which were patterned by the soft lithography. PDMS bottom surface was treated by the argon plasma and coated by the allyl alcohol (99%). The channel length was 10, 20 and 30 mm and the channel width was 100, 200 and $300\;{\mu}m$, respectively. Several external voltages were applied to make the fluid flow by the electroosmosis in the microchannel. For the same electric field strength and hydrophilicity of the bottom surface, the flow rate is almost same. This result is matched to the theoretical expectation and confirms that the experimental system is reliable. With increasing the channel width, the flow rate increased for the same hydrophilicity of the bottom surface. The flow rate of the microchannel of higher hydrophilicity was larger than that of the microchannel of lower hydrophilicity. This result implies that the hydrophilicity change of the bottom surface could be applied to control the flow rate in the microchannel.

  • PDF

Diagnostic Coincidence of Radiologic Measurement Methods of the Proximal Femur Anterior-posterior Projection for Assessment of Osteoporosis (근위대퇴부 정면 영상을 이용한 골다공증 평가 시 방사선적 계측의 진단일치도)

  • Kang, Yeong-Han;Cho, Kwang-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.6
    • /
    • pp.353-360
    • /
    • 2012
  • The purpose of this study was to determine whether there are relationships between radiologic parameters for osteoporosis by the proximal femur radiograhps and bone mineral density, as assessed by Dual Energy X-ray Absorptiometry(DEXA). Proximal femur anterior-posterior projection were taken from 112 individuals who undergoing DEXA. Radiographic parameters including canal-to-calcar ratio(CCR) and cortical thickness indices(CTI) were measured and compared with bone mineral density($g/cm^2$), T-score. The intramedullary femoral canal width(FW) and calcar width(CW) at osteoporosis group was significantly larger than that of control group. The CCR were correlated negatively with bone mineral density($g/cm^2$)(r=-0.340, p<0.01), and the CTI were correlated positively(r=0.624). The diagnostic accuracy of CCR for osteoporosis was 63.4%, and kappa value was 0.271. And the accuracy of CTI was 67.0%, and kappa value was the level of fair agreement(${\kappa}$=0.258). The proximal femur with large CCR and small CTI had lower T-scores. When evaluating proximal femur anterior-posterior radiographs, those patients with the thinnest femur diaphyseal cortices should be referred for further osteoporosis investigation.