• Title/Summary/Keyword: width control

Search Result 2,405, Processing Time 0.029 seconds

A Study for Color and Illuminance Control Algorithm of Broadcast LED Lighting (방송용 LED 조명의 광색과 조도 제어 알고리즘에 대한 연구)

  • Shin, Dong-Seok;Park, Chul-Hyung;Park, Chong-Yeun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.6-17
    • /
    • 2015
  • In this paper, colors of broadcast lightings composed of Red, Green, and Blue LED(Light Emitted Diode) can be linearly and quantitatively controlled in low illuminance. Because LED cannot emit uniform illuminance in low illuminance, the colors of RGB LED are unmixable. Furthermore, the illuminances are nonlinear with the dimming values of the RGB LED due to the nonlinearity of the output illuminance with the current through the LED. This nonlinearity generated errors of the target colors and illuminances. The proposed algorithm set up the target colors, which is expressed by the color coordinates in CIE 1931 color space, and the target illuminances. Then the illuminances of RGB LED were calculated using color mixing theory. The calculated illuminances determined the dimming values of the RGB LED for transmission via DMX512 communication. After the broadcasting lighting received the dimming values of the RGB LED via DMX512 communication,.RGB LED can emit target color and illuminance, and be controlled by calculating the PWM(Pulse Width Modulation) duty ratio of the hybrid LED driver which be considered the nonlinearity for the illuminances of the LED. As a result, the proposed algorithm can linearly and quantitatively control the colors and illuminances in full range of illuminance. Then we verify experimentally that the errors of the emitted color coordination x, y and illuminance are 2.27%, 3.6% and 1.5%, respectively.

Improvement of the Directivity of a Doppler Log Using Linear Transducer Array (직선배열 진동자에 의한 도풀러 로그의 지향특성 개선에 관한 연구)

  • 신형일;정세모
    • Journal of the Korean Institute of Navigation
    • /
    • v.5 no.2
    • /
    • pp.1-39
    • /
    • 1981
  • A doppler log is the typical device which can measure the ship's speed over the ground directly, by means of doppler effect of the underwater ultrasonic wave, which involves the error due to the sea bottom inclination, the trim and the incorrect transducer installation etc. The present doppler log adopts a single transducer, faced in the direction of themain beam, and therefore it is unable to correct the beam direction to eliminate the above mentioned error. Moreover, the frequencyis also limitted in a comparatively high range for getting a sharp beam with single transducer, and the speed over the ground can not be detectable at the deep sea, for an instance, over 200 meters. This paper describes a theoretical consideration for the doppler log error and an analysis by a computer on the observed speed data by a full size model ship. The result is verified that the most of doppler log error is caused by the ultrasonic beam angle of transducer. To eliminate the doppler log error due to the incorrect transducer installation and also to sharpen the beam for lower frequency range to expand measurable sea depth, this paper proposes a method of controlling the directivity adopting a linear transducer array and of controlling the directivity by the control of exciting current, and investigates by the computer simulation and make experiment with magnetostrictive ferrite transducer of 28, 50 and 75KHz. The experimental results are shown well coincide with the measured ones, and they are revealed that in case where the transducer interval is greater than 1 wavelength, the effective control of the beam direction is hardly performed with keeping adequate beam width and side lobe level. It is concluded that 6-elements array with inter element space of a half wavelength can make comparatively sharp beam and low side lobe level. The results obtained here will contribute very much to the improvement of the performance of doppler log.

  • PDF

New Strategy for Eliminating Zero-sequence Circulating Current between Parallel Operating Three-level NPC Voltage Source Inverters

  • Li, Kai;Dong, Zhenhua;Wang, Xiaodong;Peng, Chao;Deng, Fujin;Guerrero, Josep;Vasquez, Juan
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.70-80
    • /
    • 2018
  • A novel strategy based on a zero common mode voltage pulse-width modulation (ZCMV-PWM) technique and zero-sequence circulating current (ZSCC) feedback control is proposed in this study to eliminate ZSCCs between three-level neutral point clamped (NPC) voltage source inverters, with common AC and DC buses, that are operating in parallel. First, an equivalent model of ZSCC in a three-phase three-level NPC inverter paralleled system is developed. Second, on the basis of the analysis of the excitation source of ZSCCs, i.e., the difference in common mode voltages (CMVs) between paralleled inverters, the ZCMV-PWM method is presented to reduce CMVs, and a simple electric circuit is adopted to control ZSCCs and neutral point potential. Finally, simulation and experiment are conducted to illustrate effectiveness of the proposed strategy. Results show that ZSCCs between paralleled inverters can be eliminated effectively under steady and dynamic states. Moreover, the proposed strategy exhibits the advantage of not requiring carrier synchronization. It can be utilized in inverters with different types of filter.

Experimental Analysis of Axial Vibration in Slim-type Optical Disc Drive (슬림형 광 디스크 드라이브의 축방향 진동에 대한 실험적 해석)

  • 박대경;전규찬;이성진;장동섭
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.11
    • /
    • pp.833-839
    • /
    • 2002
  • As the demand for slim laptops requires low-height optical disc drives, vibration problems of optical disc drives are of great concern. Additionally, with the decrease of a track width and a depth of focus in high density drives, studies on vibration resonance between mechanical parts become more important. From the vibration point of view, the performance of optical disc drives is closely related with the relative displacement between a disc and an objective lens which is controlled by servo mechanism. In other words, to read and write data properly, the relative displacement between an optical disc and an objective lens should be within a certain limit. The relative displacement is dependent on not only an anti-vibration mechanism design but also servo control capability. Good servo controls can make compensation for poor mechanisms, and vice versa. In a usual development process, robustness of the anti-vibration mechanism is always verified with the servo control of an objective lens. Engineers partially modify servo gain margin in case of a data reading error. This modification cannot correct the data reading error occasionally and the mechanism should be redesigned more robustly. Therefore it is necessary to verify a mechanism with respect to the possible servo gain plot. In this study we propose the experimental verification method for anti-vibration mechanism with respect to the existing servo gain plot. Thismethod verifies axial vibration characteristics of optical disc drives on the basis of transmissibility. Using this method, we verified our mechanism and modified the mechanism for better anti-vibration characteristics.

Torque Distribution Algorithm of Independent Drive Articulated Vehicle for Small Radius Turning Performance (독립 구동 굴절차량의 회전반경 감소를 위한 토크분배 알고리즘)

  • Lee, Kibeom;Hwang, Karam;Tak, Junyoung;Suh, In-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.5
    • /
    • pp.336-341
    • /
    • 2014
  • The articulated structures seen in train or tram applications are being applied in road transportation systems, for use in mass passenger transit. When articulated vehicles are driven on public roads, they no longer follow a guided track. Therefore, there are a lot of control elements that need to be considered, such as turning radius, swept path width, off-tracking, and swing-out. Some of the currently available articulated vehicles on roads are equipped with an independent drive system; a system that has one motor at each wheel. Through this drive system, each wheel can be independently controlled, making precise and quick dynamic stability control possible. In this paper, we propose a torque distribution algorithm that can reduce the overall turning radius of the articulated vehicle, which has been verified through dynamic simulation.

Development of an Optical Tissue Clearing Laser Probe System

  • Yeo, Changmin;Kang, Heesung;Bae, Yunjin;Park, Jihoon;Nelson, J. Stuart;Lee, Kyoung-Joung;Jung, Byungjo
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.289-295
    • /
    • 2013
  • Although low-level laser therapy (LLLT) has been a valuable therapeutic technology in the clinic, its efficacy may be reduced in deep tissue layers due to strong light scattering which limits the photon density. In order to enhance the photon density in deep tissue layers, this study developed an optical tissue clearing (OTC) laser probe (OTCLP) system which can utilize four different OTC methods: 1) tissue temperature control from 40 to $10^{\circ}C$; 2) laser pulse frequency from 5 to 30 Hz; 3) glycerol injection at a local region; and 4) a combination of the aforementioned three methods. The efficacy of the OTC methods was evaluated and compared by investigating laser beam profiles in ex-vivo porcine skin samples. Results demonstrated that total (peak) intensity at full width at half maximum of laser beam profile when compared to control data was increased: 1) 1.21(1.39)-fold at $10^{\circ}C$; 2) 1.22 (1.49)-fold at a laser pulse frequency of 5 Hz; 3) 1.64 (2.41)-fold with 95% glycerol injection; 4) 1.86 (3.4)-fold with the combination method. In conclusion, the OTCLP system successfully improved the laser photon density in deep tissue layers and may be utilized as a useful tool in LLLT by increasing laser photon density.

Phase-Shift Full-Bridge DC-DC Converter using the One-Chip Micom (단일칩 마이컴을 이용한 위상변위 방식 풀브리지 직류-직류 전력변환기)

  • Jeong, Gang-Youl
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.517-527
    • /
    • 2021
  • This paper presents the phase-shift full-bridge DC-DC converter using the one-chip micom. The proposed converter primary is the full-bridge power topology that operates with the unipolar pulse-width modulation (PWM) by the phase-shift method, and the secondary is the full-bridge full-wave rectifier composed of four diodes. The control of proposed converter is performed by the one-chip micom and its MOSFET switches are driven by the bootstrap circuit. Thus the total system of proposed converter is simple. The proposed converter achieves high-efficiency using the resonant circuit and blocking capacitor. In this paper, first, the power-circuit operation of proposed converter is explained according to each operation mode. And the power-circuit design method of proposed converter is shown, and the software control algorithm on the micom and the feedback and switch drive circuits operating the proposed converter are described, briefly. Then, the operation characteristics of proposed converter are validated through the experimental results of a designed and implemented prototype converter by the shown design and implementation method in this paper. The highest efficiency in the results was about 92%.

A Study on PWM Control of Near-Infrared Fluorescence Imaging System (근적외선 형광 영상시스템의 PWM 제어에 관한 연구)

  • Lee, Byeong-Ho;Pan, Sung Bum
    • The Journal of Korean Institute of Information Technology
    • /
    • v.16 no.11
    • /
    • pp.115-121
    • /
    • 2018
  • Fluorescent images using near-infrared light have no worry about radioactivity, and images can be checked in real time during surgery. Therefore experiments using fluorescent images for monitoring lymph node biopsy are actively under way. Fluorescent imaging equipment uses high heat-generating components such as LED and camera, thus uses water-cooling system as a stable heating suppression means. However in the fluorescent image equipment, the water cooling system takes a large volume which is a disadvantage in terms of miniaturization of the equipment. Even if the air cooling system is used for miniaturizing the equipment, heat generation is a problem. In this paper, we have experimented with the air cooling method using PWM control for the miniaturization of the equipment, and confirmed the constant quality of the fluorescent image and the suppression of the heat generation without any problems even when the equipment is used for a long time.

Active Antenna Module for 60 GHz Frequency Band (60 GHz 대역 능동 안테나 모듈 설계)

  • Ahn, Se-In;Yun, Sang-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.6
    • /
    • pp.518-521
    • /
    • 2019
  • In this paper, an active antenna module operating in the 60 GHz band is designed and fabricated by combining a commercial transmitter chip and patch array antenna. The designed module is composed of an antenna PCB and a PCB with a transmitter chip. The frequency-control and bias-control signals are applied to the transmitter chip, using an Arduino kit. A baseband I/Q signal is also applied to the chip. A ring hybrid balun converts the output of the transmitter module to a single output, which is the output of the transmitter chip that outputs a differential output. The output is delivered to the $2{\times}4$ microstrip patch array antenna PCB as a micro-computer connector. The radiation pattern of the millimeter-wave signal of the final output is compared with the simulation results. The measured radiation patterns of the fabricated active antenna module confirm that the positions of the 3 dB beam width and null point agree well with the simulation results.

Three-dimensional analysis of facial asymmetry after zygomaticomaxillary complex fracture reduction: a retrospective analysis of 101 East Asian patients

  • Cho, Jakwang;Kim, Youngjun;Choi, Youngwoong
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.3
    • /
    • pp.148-153
    • /
    • 2021
  • Background: The zygomaticomaxillary complex (ZMC) has a protruded, convex shape and plays a vital role in determining the contour by affecting the width of the middle face. This study aimed to evaluate the efficiency of ZMC fracture reduction and explore detailed directions for outcome improvement. Methods: We conducted a retrospective study of patients diagnosed with unilateral ZMC fracture who underwent ZMC reduction surgery at a single hospital between January 2015 and May 2020. The primary outcome variable was facial asymmetry using the difference in the bilateral malar eminence (ME) position measured by computed tomography scan. The 3-dimensional distance (IA, asymmetry index) and the distance in each dimension, Dx (anteroposterior distance), Dy (mediolateral distance), and Dz (superoinferior distance) were compared. Results: A total of 101 patients with ZMC fractures and 54 non-fracture patients were enrolled in the study. The mean age of the study sample was 43.49 years (control sample, 43.35 years), and the male-to-female ratio was 66.3:33.7 (control sample, 64.8:35.2). There were 53 and 48 patients with right and left ZMC fractures, respectively. The IA was not statistically different between the two groups. In terms of position in each dimension, only Dx was significantly different between the two groups. Conclusion: The results show that overall facial asymmetry was recovered after ZMC reduction, but in certain dimension significant difference in ME position has still remained. For further improvement, treatment should be performed to relieve malar depression in the anteroposterior dimension.