• Title/Summary/Keyword: width control

Search Result 2,405, Processing Time 0.028 seconds

A Study on Digital Control Method of LED Luminance (LED 휘도의 디지털 제어 방식에 관한 연구)

  • Kang, Shin-Ho;Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.28-34
    • /
    • 2010
  • The pulse width modulation(PWM) method has been generally used as conventional method controlling luminance of LED(light emitting diode). PWM method as analog method with a relation that duty ratio of LED be proportional to luminance has weak point that it is not compatible with digital method of communication etc. In this paper, a experiment is conducted which the luminance of RGB LED be controlled by digital method. For this, the LED digital control system is developed which consist of LED driving circuits and digital logic circuits. By controlling the number of pluses on RGB LED versus digital input, various lighting colors is implemented and digital codes are optimized in order that measured x, y chromaticity coordinates of lighting colors are comprised in the CIE chromaticity coordinates area of targeted lighting colors. The result of this study can be utilized usefully in research on implementing full color by using remote control of LED lamp with digital communication.

Online Automatic Gauge Controller Tuning Method by using Neuro-Fuzzy Model in a Hot Rolling Plant

  • Choi, Sung-Hoo;Lee, Young-Kow;Kim, Sang-Woo;Hong, Sung-Chul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1539-1544
    • /
    • 2005
  • The gauge control of the fishing mill is very important because more and more accurately sized hot rolled coils are demanded by customers recently. Because the mill constant and the plasticity coefficient vary with the specifications of the mill, the classification of steel, the strip width, the strip thickness and the slab temperature, the variation of these parameters should be considered in the automatic gauge control system(AGC). Generally, the AGC gain is used to minimize the effect of the uncertain parameters. In a practical field, operators set the AGC gain as a constant value calculated by FSU (Finishing-mill Set-Up model) and it is not changed during the operating time. In this paper, the thickness data signals that occupy different frequency bands are respectively extracted by adaptive filters and then the main cause of the thickness variation is analyzed. Additionally, the AGC gain is adaptively tuned to reduce this variation using the online tuning model. Especially ANFIS(Adaptive-Neuro-based Fuzzy Interface System) which unifies both fuzzy logics and neural networks, is used for this gain adjustment system because fuzzy logics use the professionals' experiences about the uncertainty and the nonlinearity of the system. Simulation is performed by using POSCO's data and the results show that proposed on-line gain adjustment algorithm has a good performance.

  • PDF

Light environment and physiological response of Panax ginseng I. Experience on light in natural habitat,through cultivation under forest and artificial shade, and change of light control technique (인삼의 광환경과 생리반응 I.자생지. 임간 및 일복 재배에서 광경험과 광조절 방법의 변천)

  • Park, Hoon
    • Journal of Ginseng Research
    • /
    • v.7 no.2
    • /
    • pp.172-192
    • /
    • 1983
  • Light environment and growth of Panax ginseng In habitat and cultivation under natural shade were renewed. Grower's experiences on ginseng stand In relation to light environment were assessed. Change of shading method and grower's concepts on light requirement of ginseng plant in Korea, Manchuria and Japan was counted. Growth of wild ginseng was better under rich light. Optimum crown density index appeared to be 0.7 In natural habitat and 0.4 to 0.7 for the cultivation in forest. Change of light Intensity in forest was greatest in May and reached near to constant value (from 40% to 3% for broad leaf deciduous forest and loom 4% to 2% for pine forest). Insufficient light condition induced long and thin stem, poor flowering and seed bearing, and sequent dormancy. Relation between light and ginseng strand was not clear but light Interception with cool weather was effective. Topography and orientation of bed have been deeply considered for light environment. Panel or bark of won were used for shading in deep forest manly In Manchuria while reed blind and straw thatch were used in Korea. Kinds and number of shades material and seasonal or daily schedule have been simplified probably by labor pressure due to eulargement of plantation. Post height has been greater while width of roof, bed and ditch has changed lisle. Scientific survey in the past omitted important light control methods (complete light hardening etc) which has been practiced in specific areas. The concept and technique of light control in the past in Korea were delicate and intensive including the control of temperature and moisture. For the application of old concept in modem cultivation precise Investigation of the technique including the measurement of light, temperature and moisture is needed.

  • PDF

Flexural behaviour of reinforced low-strength concrete beams strengthened with CFRP plates

  • Boukhezar, Mohcene;Samai, Mohamed Laid;Mesbah, Habib Abdelhak;Houari, Hacene
    • Structural Engineering and Mechanics
    • /
    • v.47 no.6
    • /
    • pp.819-838
    • /
    • 2013
  • This paper summarises the results of an experimental study to investigate the flexural behaviour of reinforced concrete beams strengthened using carbon-fibre reinforced polymer (CFRP) laminate in four-point bending. The experimental parameters included are the reinforcing bar ratio ${\rho}_s$ and preload level. Four bar ratios were selected (${\rho}_s=0.13$ to 0.86%), representing the section of two longitudinal tensile reinforcements, with diameters of 8, 14, 16, and 20 mm in order to reveal the effect of bar ratio on failure load and failure mode. Eight beams that could be considered "full-scale" in size, measuring 200 mm in width, 400 mm in total height and 2300 mm in length, were tested. Three beams were selected with different bar ratios (${\rho}_1$, ${\rho}_2$, ${\rho}_3$), and considered as control specimens (without ), while three other beams identical to the control beams with the same CFRP laminates ratio and a seventh beam with ${\rho}_{min}$ (the lowest bar ratio) were also used. In the second part of the study, two beams with the bar ratio ${\rho}_2$ were preloaded at two levels, 50 and 100% of their ultimate loads, and then repaired. This experimental investigation was consolidated using an analytical model. The experimental and analytical results indicate that the flexional capacity and stiffness of strengthened and repaired beams using CFRP laminate were increased compared to those of control beams, and the behaviour of repaired beams was nearly similar to the undamaged and strengthened beams; unlike the ductility of strengthened beams, which was greatly reduced compared to the control.

An Experimental Study on the Optimum Design of Sirocco Fan by Using Taguchi Method (다구찌 방법을 이용한 시로코 홴의 최적설계에 관한 실험적 연구)

  • Kim, Jang Kweon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.6
    • /
    • pp.761-768
    • /
    • 1999
  • This paper is studied to find the optimum condition of double-inlet Sirocco fan installed in an indoor PAC for low noise operation by the Taguchi method. The goal of this study is to obtain the best combination of each control factor which results in a desired flowrate of Sirocco fan with minimum variability. In this study, the parameter design of the Taguchi method is adopted for robust design by the dynamic characteristic analysis using orthogonal arrays and S/N ratios. The flowrate measurements are conducted by using a multiple-nozzle-type fan tester according to the orthogonal array L9($3^4$). The results of this study can be summarized as follows ; (i) The optimum condition of control factor is a set of where A is an inner to outer diameter ratio($D_1/D_2$), B is a width to outer diameter ratio($L/D_2$), C is a blade attachment angle(${\theta}$) and D is a number of blade(Z), (ii) The flowrate under the optimum condition satisfies the equation $y=0.0384{\cdot}M$ where M is a signal factor, namely number of revolution. The flowrate performance improves about 7.3% more largely as compared with the current condition, which results in about 35RPM reduction of number of revolution for the target flowrate $18.5m^3/min$, and (iii) The sensitivity analysis shows that the major factors in contribution to flowrate performance are A, B, and D ; the percentage contributions of each control factor are 44.01%(Z), 26.77%($D_1/D_2$) and 20.42%($L/D_2$).

A Study on the Harmonic Current Characteristics of Universal Motro with Speed Controller (유니버셜모터 속도제어기의 고조파전류 특성에 관한 연구)

  • 임홍우;박수강;백형래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.132-140
    • /
    • 2001
  • A universal motor is a small dc series machine motor that is designed to operate from an ac machine. The characteristics of universal motors are high no-load and staring torque. Because of the high operating speed, the size of these motors for a given hp rating is typically smaller that other fractional hp ac machine, making it ideal for hand-held tools and appliances where weight, compactness, and speed are importance factors. A phase-angle control with AC drive system gains a high popularity due to their simple implementation, but contains the disadvantage of their poor input power factor, subharmonic current. Pulse width modulation control with DC drive systems increase the power factor as without delay phase angle. This paper analyzed the subharmonic characteristics of the phase angle control system that is controlled by zero voltage crossing similar to traditional method, and the dc chopper system that is used PWM.

  • PDF

An Experimental Study on the Effect of Hanji Windows on Indoor Air Temperature and Humidity Control (한지창호의 실내 온.습도 조절효과에 관한 실험적 연구)

  • Jang Gil-Soo;Park Sa-Keun;Song Min-Jeong;Shin Hoon
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.125-134
    • /
    • 2006
  • The tightness of windows have devoted to the improvement of thermal insulation and energy saving in buildings. But it is known that this tightness causes some side effects such as low ventilation, low capacity to humidity and temperature control and these are not profitable for inhabitants. To act on these side effects, Korean traditional windows which are composed of Han-Ji(Koreand traditional paper) and Chang-Sal(Korean traditional wooden frame) have been studied to get a reasonable solutions for these problems. In this study, to compare the thermal and humidity control performance of current window(12 mm pair) and Korean traditional windows, frames which are made of existing window and Korean traditional windows are adapted to scale model house and then humidity and temperature of in and out of scale model house are measured and analysed. The results of this study are followings ; 1) When Korean traditional window charges 20cm(1/8 of total window area) from total window area, Han-Ji window has higher thermal insulation than that of existing window in daytime. There is the most big thermal difference when double faced with double-ply Han-Ji window is placed to mock-up house. In night-time, the temperature difference is very small so this means that Korean traditional window is good to cover direct sunlight in daytime and reduce the temperature of balcony. One faced with one-ply han-Ji window has the best humidity penetration performance among three type of Korean traditional windows. 2) When Korean window area enlarged to 40cm(1/4 of total window area), the function of 40cm width Han-Ji window is higher than that of 20cm's. This means that enlargement of Han-Ji window cover direct sunlight more and is more efficient in humidity penetration.

Altered Calcium Current of the Vascular Smooth Muscle in Renal Hypertension

  • Nam, Sang-Chae;Jeong, Hye-Jeon;Kim, Won-Jae;Lee, Jong-Un
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.3 no.3
    • /
    • pp.351-356
    • /
    • 1999
  • The present study was aimed at investigating whether the calcium current in the vascular smooth muscle (VSM) cells is altered in renal hypertension. Two-kidney, one clip (2K1C) and deoxycorticosterone acetate (DOCA)-salt hypertension were made in Sprague-Dawley rats. Rats without clipping the renal artery or implanting DOCA were used as control for 2K1C and DOCA-salt hypertension, respectively. Four weeks after clipping, systolic blood pressure was significantly higher in 2K1C rats than in control $(192{\pm}24\;and\;119{\pm}4$ mmHg, respectively, n=16 each). DOCA-salt rats also showed a higher blood pressure $(180{\pm}15$ mmHg, n=18) compared with control $(121{\pm}6$ mmHg, n=14). VSM cells were enzymatically and mechanically isolated from basilar arteries. Single relaxed VSM cells measured $5{\sim}10\;{\mu}m$ in width and $70{\sim}150\;{\mu}m$ in length were obtained. VSM cells could not be differentiated in size and shape between hypertensive and normotensive rats under light microscopy. High-threshold (L-type) calcium currents were recorded using whole-cell patch clamp technique. The amplitude of the current recorded from VSM cells was larger in 2K1C hypertension than in control. Neither the voltage-dependence of the calcium current nor the cell capacitance was significantly affected by 2K1C hypertension. By contrast, the amplitude of the calcium current was not altered in DOCA-salt hypertension. These results suggest that high-threshold calcium current of the VSM cells is altered in 2K1C hypertension, and that calcium channel may not be involved in calcium recruitment of VSM in DOCA-salt hypertension.

  • PDF

The Design of DC-DC Converter with Green-Power Switch and DT-CMOS Error Amplifier (Green-Power 스위치와 DT-CMOS Error Amplifier를 이용한 DC-DC Converter 설계)

  • Koo, Yong-Seo;Yang, Yil-Suk;Kwak, Jae-Chang
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.90-97
    • /
    • 2010
  • The high efficiency power management IC(PMIC) with DTMOS(Dynamic Threshold voltage MOSFET) switching device and DTMOS Error Amplifier is presented in this paper. PMIC is controlled with PWM control method in order to have high power efficiency at high current level. Dynamic Threshold voltage CMOS(DT-CMOS) with low on-resistance is designed to decrease conduction loss. The control parts in Buck converter, that is, PWM control circuits consist of a saw-tooth generator, a band-gap reference circuit, an DT-CMOS error amplifier and a comparator circuit as a block. the proposed DT-CMOS Error Amplifier has 72dB DC gain and 83.5deg phase margin. also Error Amplifier that use DTMOS more than CMOS showed power consumption decrease of about 30%. DC-DC converter, based on Voltage-mode PWM control circuits and low on-resistance switching device is achieved the high efficiency near 96% at 100mA output current. And DC-DC converter is designed with Low Drop Out regulator(LDO regulator) in stand-by mode which fewer than 1mA for high efficiency.

Experimental Study on the Inflow and Outflow Structures of Hwasun Flood Control Reservoir (화순 홍수조절지의 유입유출 구조물에 대한 수리모형실험 연구)

  • Lee, Sang-Hwa;Jin, Kwang-Ho;Ryu, Jong-Hyun;Kim, Soo-Geun
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.7
    • /
    • pp.675-684
    • /
    • 2012
  • Recently, a heavy rainfall under climate change causes the flood exceeded river's conveyance. Flood control methods under the limited river width are the increase of embankment, the construction of storage pockets and diversion channel, the dredging of river bed. Hwasun flood control reservoir of washland is designed as the storage pockets and the regulating gate for the control of water level. In this study, the propriety of design was investigated through hydraulic experiments for the circumstances to exclude the constant flood discharge during operation period. In the results, the over flow rate of side weir exceeded the flow of design and indicated to be able to discharge the designed flow in the regulating gate opened 1.1 m. The high velocity 7.1 m/s behind the gate has investigated to reduce under 3.3 m/s by the baffle block.