• 제목/요약/키워드: white-light scanning

검색결과 106건 처리시간 0.024초

Accurate Roughness Measurement Using a Method for Evaluation and Interpolation of the Validity of Height Data from a Scanning White-light Interferometer

  • Kim, Namyoon;Lee, Seung Woo;I, Yongjun;Pahk, Heui-Jae
    • Current Optics and Photonics
    • /
    • 제1권6호
    • /
    • pp.604-612
    • /
    • 2017
  • An effective and precise method using a scanning white-light interferometer (SWLI) for three-dimensional surface measurements, in particular for roughness measurements, has been proposed. The measurement of a microscopically sloped area using an interferometer has limitations, due to the numerical aperture of the lens. In particular, for roughness measurements, it is challenging to obtain accurate height data for a sloped area using the interferometer, due to diffraction of the light. Owing to these optical limitations of the interferometer for roughness measurements, the Ra measurements performed using an interferometer contain errors. To overcome the limitations, we propose a method consisting of the following two steps. First, we evaluate the height data and set the invalid height area to be blank, using the characteristics of the modulus peak, which has a low peak value for signals that have low reliability in the interferogram. Next, we interpolate the blank area using the adjacent reliable area. Rubert roughness standards are used to verify the proposed method. The results obtained by the proposed method are compared to those obtained with a stylus profilometer. For the considered sinusoidal samples, Ra ranges from $0.053{\mu}m$ to $6.303{\mu}m$, and we show that the interpolation method is effective. In addition, the method can be applied to a random surface where Ra ranges from $0.011{\mu}m$ to $0.164{\mu}m$. We show that the roughness results obtained using the proposed method agree well with profilometer results. The $R^2$ values for both sinusoidal and random samples are greater than 0.995.

구면좌표계식 기구를 이용한 3D 스캐닝 장치의 정밀도 평가 (An Evaluation on the Accuracy of a 3D Scanning Device Using Spherical Coordinate Mechanisms)

  • 맹희영;박상욱
    • 한국생산제조학회지
    • /
    • 제24권1호
    • /
    • pp.1-6
    • /
    • 2015
  • To improve the efficiency of a reverse engineering process, many researches have recently tried to develop efficient, automatic 3D scanning devices. A new automatic 3D scanning device using a spherical coordinate system mechanism is introduced in this study. This device incorporates a guide motion along the spherical coordinate to compound each 3D data point automatically. The experiments correlating the system assembling tolerance with the form accuracy were conducted to verify the efficiency of the system for the scanning of an object, including complex shapes and manifold sections. In addition, the required time and system accuracy, taken during the scanning process of complicated artifact models, were investigated. Further, based on these empirical results, it was ascertained that the superior productivity of this new device offers a more precise and efficient scan when compared to conventional methodologies.

대면적 백색광 간섭계의 3차원 높이 연산 고속화 알고리즘 개발 (Development of High Speed 3D height Measurement for White light Scanning Interferometer)

  • 심재환;고국원
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 춘계학술논문집 2부
    • /
    • pp.761-764
    • /
    • 2011
  • 본 연구에서는 대면적 백색광 간섭계의 개발과 개발 되어진 대면적 백색광 간섭계의 고속화를 위하여 Multi-PC를 이용한 동기화 이미지 획득 및 이미지 분할연산과 최적의 Multi-Thread 구성을 통한 영역분할 ROI 알고리즘에 대한 연구결과를 기술하였다.

  • PDF

가상의 백색광 주사 간섭계의 개발 (Virtual White-light Scanning Interferometer)

  • 김영식;김승우
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 제14회 정기총회 및 03년 동계학술발표회
    • /
    • pp.88-89
    • /
    • 2003
  • 산업이 고도로 발달함에 따라 생산 부품의 소형화와 정밀도가 크게 요구되고 있다. 특히 최첨단 제품인 반도체와 광통신 부품, 그리고 광학 부품 등에 있어 이러한 추세가 두드러지게 나타나고 있다. 이에 따라 이들 부품들에 대한 제조 공정 못지 않게 초정밀 측정에 대한 관심도 꾸준히 늘고 있다. 뿐만아니라 요즘 새롭게 부각되고 있는 생명 공학 기술(Bio-Technology)과 나노기술(Nano-Technology)을 이용한 바이오센서나 칩, 그리고 타소 나노 튜브 등을 제작하거나 검사를 할 때도 초정밀 측정을 필요로 하게 된다. (중략)

  • PDF

광학 영상의 강인한 정합 알고리즘 (Robust Matching Algorithm for Optical Images)

  • 양한진;주영훈
    • 제어로봇시스템학회논문지
    • /
    • 제17권3호
    • /
    • pp.248-253
    • /
    • 2011
  • This paper proposes the robust matching algorithm for optical images obtained by WSI(White-light Scanning Interferometer) machine. The matching algorithms are divided by two part according to the matching points: algorithm whether the matching points between two images exist or not. Also, after matching the images, we propose the algorithm to smooth the matched image. Finally, we show the effectiveness and feasibility of the proposed method through some experiments.

백색 LED용 Ca3MgSi2O8:Eu2+ 백색 형광체의 발광특성 (Luminescent Characteristics of Eu2+- Doped Ca3MgSi2O8:Eu2+ White Phosphors for LED)

  • 유일
    • 한국재료학회지
    • /
    • 제28권8호
    • /
    • pp.474-477
    • /
    • 2018
  • $Ca_3MgSi_2O_8:Eu^{2+}$(x = 0.003, 0.005, 0.007, 0.01, 0.03 mol) white phosphors for Light Emitting Diodes(LED) are synthesized with different concentrations of $Eu^{2+}$ ions using a solid state reaction method. The crystal structures, surface and optical properties of the phosphors are investigated using X-Ray Diffraction(XRD), Scanning Electron Microscope(SEM) and photoluminescence(PL). The X-Ray Diffraction results reveals that the crystal structure of the $Ca_3MgSi_2O_8:Eu^{2+}$ is a monoclinic system. The particle size of $Ca_3MgSi_2O_8:Eu^{2+}$ white phosphors is about $1{\sim}5{\mu}m$, as confirmed by SEM images. The maximum emission spectra of the phosphors are observed at 0.01 mol $Eu^{2+}$ concentration. The decrease in PL intensity in the $Ca_3MgSi_2O_8:Eu^{2+}$ white phosphors with $Eu^{2+}$ concentration is interpreted by concentration quenching. The International Commission on Illumination(CIE) coordinate of 0.01 mol Eu doped $Ca_3MgSi_2O_8$ is X = 0.2136, Y = 0.3771.

SrSnO3:Dy3+ 백색광 형광체의 발광 특성 (Photoluminescence Properties of SrSnO3:Dy3+ White Light-Emitting Phosphors)

  • 신종언;조신호
    • 한국전기전자재료학회논문지
    • /
    • 제30권11호
    • /
    • pp.710-716
    • /
    • 2017
  • New white-light-emitting $SrSnO_3:Dy^{3+}$ phosphors were prepared using different concentrations of $Dy^{3+}$ ions via a solid-state reaction. The phase structure, luminescence, and morphological properties of the synthesized phosphors were investigated using X-ray diffraction analysis, fluorescence spectrophotometry, and scanning electron microscopy, respectively. All the synthesized phosphors crystallized in an orthorhombic phase with a major (020) diffraction peak, irrespective of the concentration of $Dy^{3+}$ ions. The excitation spectra were composed of a broad band centered at 298 nm, ascribed to the $O^2-Dy^{3+}$ charge transfer band and five weak bands in the range of 350~500 nm. The emission spectra of $SrSnO_3:Dy^{3+}$ phosphors consisted of three bands centered at 485, 577, and 665 nm, corresponding to the $^4F_{9/2}{\rightarrow}^6H_{15/2}$, $^4F_{9/2}{\rightarrow}^6H_{13/2}$, and $^4F_{9/2}{\rightarrow}^6H_{11/2}$ transitions of $Dy^{3+}$, respectively. As the $Dy^{3+}$ concentration increased from 1 to 15 mol%, the intensities of all the emission bands gradually increased, reached maxima at 15 mol% of $Dy^{3+}$ ions, and then decreased rapidly at 20 mol% due to concentration quenching. The critical distance between neighboring $Dy^{3+}$ ions for concentration quenching was calculated to be $9.4{\AA}$. The optimal white light emission by the $SrSnO_3:Dy^{3+}$ phosphors was obtained when the $Dy^{3+}$ concentration was 15 mol%.

다공성 실리콘 기판위에 Plasma-assisted molecular beam epitaxy으로 성장한 산화아연 초박막 보호막의 발광파장 조절 연구 (Emission wavelength tuning of porous silicon with ultra-thin ZnO capping layers by plasma-assited molecular beam epitaxy)

  • 김소아람;김민수;남기웅;박형길;윤현식;임재영
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 춘계학술발표회 논문집
    • /
    • pp.349-350
    • /
    • 2012
  • Porous silicon (PS) was prepared by electrochemical anodization. Ultra-thin zinc oxide (ZnO) capping layers were deposited on the PS by plasma-assisted molecular beam epitaxy (PA-MBE). The effects of the ZnO capping layers on the properties of the as-prepared PS were investigated using scanning electron microscopy (SEM) and photoluminescence (PL). The as-prepared PS has circular pores over the entire surface. Its structure is similar to a sponge where the quantum confinement effect (QCE) plays a fundamental role. It was found that the dominant red emission of the porous silicon was tuned to white light emission by simple deposition of the ultra-thin ZnO capping layers. Specifically, the intensity of white light emission was observed to be enhanced by increasing the growth time from 1 to 3 min.

  • PDF

지역 분할과 다중 라이트 빔을 이용한 3차원 얼굴 형상 모델링 기법 (A 3D Face Modeling Method Using Region Segmentation and Multiple light beams)

  • 이요한;조주현;송태경
    • 전자공학회논문지CI
    • /
    • 제38권6호
    • /
    • pp.70-81
    • /
    • 2001
  • 본 논문에서는 한 개의 카메라와 한 대의 환등기(LCD 환등기 혹은 슬라이드 환등기)를 이용하여 2차원 얼굴 영상으로부터 3차원 얼굴 형상을 모델링하는 방법을 제안한다. 환등기를 이용하여 사람 얼굴에 라이트 빔을 투영하고 이를 조금씩 이동시키며 영상을 획득한 뒤 각 2차원 영상의 지역적 정보와 영상들 사이의 시간적 정보를 함께 이용하여 3차원 형상을 복원하는 방법을 채택하였다. 제안된 방법에서는 특정이 서로 다른 영역들의 효과적인 3차원 좌표 모델링을 위해 영상을 그림자 부분 얼굴 부분 그리고 머리카락 부분으로 나누어 처리하는 지역 분할(region segmentation) 기법을 도입하였고, 2차원 얼굴 영상 획득 시간을 줄이고 고속 3차원 스캔을 위하여 한 영상 안에 다수의 라이트 빔(multiple light beams)을 이용하였다. 또 한 라이트 빔의 경계를 정확하게 검출하기 위하여 라이트 빔 캘리브레이션(light beam calibration) 기법을 제안하여 사용하였다. 실험 결과 제안한 방법을 통해서 머리카락 부분을 포함한 전체 얼굴 영역에서 향상된 3차원 모델링 결과를 얻을 수 있었다.

  • PDF

Optical Coherence Tomography를 이용한 원발성 맥락망막염 이환견의 진단 및 치료 (The Diagnosis and Treatment of Primary Chorioretinitis using Optical Coherence Tomography in a Dog)

  • 지동범;유석종;서강문;정만복
    • 한국임상수의학회지
    • /
    • 제30권4호
    • /
    • pp.324-328
    • /
    • 2013
  • A 5-year-old intact male Yorkshire terrier dog was referred with a 1-week history of blindness. In both eyes, menace responses and pupillary light reflexes were absent. The indirect ophthalmoloscopy revealed multiple small gray-white and discoloration lesion in mid-nontapetum area in both eyes. Electroretinograms showed diminished amplitude of a- and b-waves. Multifocal serous retinal detachments were detected with optical coherence tomography (OCT) over the small gray-white and discoloration lesion in the fundus. After one week of treatments, the indirect ophthalmoloscopy showed that irregular patches and hyperpigmentation in the center of hyperreflectivity area. Reattachment and retinal thinning were observed by the OCT. The results indicate that OCT scanning is considered to be a useful method for retinal evaluation in dogs with chorioretinitis.