• Title/Summary/Keyword: wetting and drying

Search Result 193, Processing Time 0.028 seconds

Effect of Highly Water Absorbing Polymer(K-sorb) on Soil Water Retention (토양의 수분보유(水分保有)에 미치는 초흡수성 고분자중합체(高分子重合體)(K-sorb)의 효과)

  • Yoo, Sun-Ho;Kwun, Sun-Kuk;Ro, Hee-Myeong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.23 no.3
    • /
    • pp.173-179
    • /
    • 1990
  • The effect of a highly water absorbing polyacrylate polymer, commonly called K-sorb, at rates of 0.0, 0.05, 0.2, and 0.5% by weight on the water retention properties of three soils, and the longevities of these treatment effects were evaluated. Water retentions were measured for all the treatments by use of a pressure-plate extractor in the laboratory. Available water and three-phase distributions at moisture tensions of 0.01, 0.3, and 15b were calculated from water retentivity data. A randomized block experiment of Chinese cabbages was conducted to examine the effects and the longevities of the treatments(0.0, 0.05, 0.1, and 0.2%) on water retention of Jungdong sandy loam soil in the field. Water retentions for a loamy sand, sandy loam, and loam soil, treated with 0.2 and 0.5% K-sorb, were increased. K-sorb treatments were more effective in sandy soil than in loamy soils. Water contents for the 0.5% treatment were markedly greater than those for the 0.2% treatment at earth moisture tension. K-sorb only at a rate of 0.5% remained effective in water retention of each soil through repeated drying and wetting for 12 months. Duncan's multiple range showed 0.2% treatment was effective(at the level of 0.05) after 2 months but not after 10 months under field condition.

  • PDF

Evaluation of Apparent Chloride Diffusion Coefficient of Fly Ash Concrete by Marine Environment Exposure Tests (해양 환경 폭로 시험을 통한 FA 콘크리트의 겉보기 염화물 확산계수 평가)

  • Yoon, Yong-Sik;Lim, Hee-Seob;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.119-126
    • /
    • 2019
  • In case of RC(Reinforced Concrete) structures which are constructed in coastal areas, chloride ions in sea water corrode the steel rebar in concrete. Especially in coastal areas, RC structures are affected by not only immersion of sea water, but also tidal of sea water and airborne chloride ions. In this study, marine environment exposure tests are conducted, considering 3 types of exposure environments(immersion zone, tidal zone, splash zone) and the exposure periods of 180 days, 365 days, and 730 days. Also, the concrete mixtures for this study are established, considering 3 levels of W/B(Water to Binder) ratio(0.37, 0.42, 0.47) and 2 levels of substitution rate of Fly ash(0 %, 30 %). In all exposure environments, Fly ash concrete has lower apparent chloride diffusion coefficients than OPC concrete. It is thought that fly ash's pozzolan reaction improves chloride resistance of concrete. Fly ash concrete has up to 63.5 % of decreasing rate in 180 days of exposure and up to 55.8 % of decreasing rate in 730 days of exposure, based on diffusion coefficients of OPC concrete. As a result of evaluation about effects of exposure environments, apparent chloride diffusion coefficients of fly ash concrete are evaluated in order of tidal zone, immersion zone, and splash zone. In tidal zone, It is thought that repeated cycles of wetting and drying of sea water cause the diffusion of chloride ions rapidly.

Corrosion-Resisting Performance Evaluation of Concrete Mixed with Fly-Ash (플라이애시 혼합 콘크리트의 철근 부식 저항성능 평가)

  • Park, Sang-Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.117-125
    • /
    • 2017
  • The role of fly ash in concrete become impotent with finding the characteristics of fly ash in which it is used as cement replacement material. In this paper, corrosion test results obtained by two test methods such as the long-term exposure corrosion test and the accelerated corrosion test method, were compared to investigated the corrosion resistance between fly ash concrete and normal concrete. Corrosion initiation time was measured in two types of concrete, i.e., one mixed with fly ash(FA) and the other without admixture(OPC). The accelerated corrosion test was carried out by four case, i.e., two samples is a cyclic drying-wetting method combined without carbonation(case 1) and combined with carbonation(case 2), and the other two samples is a artificial seawater ponding test method combined without carbonation(case 3) and combined with carbonation(case 4). Whether corrosion occurs, it was measures using half-cell potential method. The ponding test combined without carbonation was most effective in accelerating corrosion time of steel bars. The results indicated that the corrosion of rebar embedded in concrete occurred according to the order of OPC, FA. The delay relative ratio of corrosion obtained by corrosion initiation time between FA and OPC is 1.04 to 1.27. Consequently, fly ash concrete as the age increases its corrosion resistance was improved compared with OPC concrete.

A Study on the Applicability of $C_5$ Hydrofluoroether-based Formulated Cleaning Agents as CFC-Alternatives ($C_5$계 수소불화에테르를 기반으로 하는 배합 세정제의 CFC 대체세정제 적용 연구)

  • Min, Hye-Jin;Bae, Jae-Heum;Chang, Yoon-Sang
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.172-181
    • /
    • 2010
  • Hydrofluoroethers (HFEs) with fluoride molecules in their structure which are evaluated as the third generation replacement alternatives to chlorofluorocarbons (CFCs) are known to be excellent for removal of nanoparticles and fluoride-type soils due to their low surface tension and high wetting index. In addition, HFEs have good physical properties with no flash point and excellent drying characteristics. But, HFEs also have shortcomings in that they are not effective for removal of organic soils due to their poor solubility in soil. In this study, $C_5$ HFE-based cleaning agents were formulated through addition of solvents such as isopropyl alcohol (IPA), ethyleneglycol monoether (EG), propyleneglycol monoethylether (PM) to HFE-7100 [$CF_3CF_2CF_2CF_2OCH_3$] or HFE-mec-f [$CF_3CHF=CF_2OCH_2CF_3$] with its maximum amount, respectively, in order to have no flash point for the safety in the working environment. These solvents are known to be excellent for dissolving organics in soil. Their physical properties and cleaning abilities for fluxes, water-insoluble cutting oils, and fluoride-type oils were evaluated and compared with those of other cleaning agents with single components. The experimental results show that the HFE-based formulated cleaning agents have various good physical properties which are almost similar to those of a single type of HFE cleaner. They show excellent cleaning ability for fluxes, water-insoluble cutting oils, and fluoride-type oils. These results indicate that the HFE-based formulated cleaning agents can be applicable to various industrial cleaning fields because of their good physical properties and cleaning abilities for various soils.

Factors Affecting Dark Germination of Oenothera lamarckiana Seeds (큰달맞이꽃 종자(種子)의 암발아(暗発芽)에 영향(影響)을 미치는 요인(要因))

  • Kim, J.S.;Hwang, I.T.;Hong, K.S.;Cho, K.Y.
    • Korean Journal of Weed Science
    • /
    • v.7 no.3
    • /
    • pp.257-264
    • /
    • 1987
  • Effect of various physical and chemical treatments on dark germination of Oenothera lamarckiana seeds were primarily investigated to find out factors affecting germination. Germination of seeds which did not germinate in the constant temperature and darkness was induced by several physical treatments such as sonification, wetting and drying, freezing and thawing, and removal of seed coat. Pretreatment of chilling ($4^{\circ}C$), freezing ($-10^{\circ}C$) and incubation at high temperature ($80^{\circ}C$) induced dark germination of seeds which did not germinate in the constant temperature ranges of 15 to $40^{\circ}C$ under darkness. Alternating temperature also had a stimulatory effect on dark germination of Oenothera lamarckiana seeds. Sensing of seeds to alternating temperature appeared to be completed during the first two days after imbibition. The minimum difference of temperature required for dark germination was $5^{\circ}C$ in the range of $15-25^{\circ}C$. A thiourea (1.0%) treatment induced dark germination, but GA, IAA, BA and Ethrel failed to do so.

  • PDF

Herbicidal Response and Germination Characteristics of Green kyllinga(Kyllinga brevifolia var. leiolepsis H.) Propagules (파대가리(Kyllinga brevifolia var. leiolepsis H.) 번식기관의 발아특성과 제초제에 대한 반응)

  • Kim, J.S.;Park, E.Y.;Choi, J.S.;Choi, S.H.;Cho, K.Y.
    • Korean Journal of Weed Science
    • /
    • v.16 no.4
    • /
    • pp.309-316
    • /
    • 1996
  • In this study, germination characteristics and herbicidal response of green kyllinga(Kyllinga brevifolia var. leiolepsis H.) were investigated. The storage method desirable for a rapid dormancy release was to keep the seed under low temp. and wetting condition for one to two months, or high temp($40^{\circ}C$) and drying condition for three months. The dormancy of rhizome was hardly observed. The optimum temperature for germination of seed and rhizome was around $30^{\circ}C$ and 16-$20^{\circ}C$, repectively. The germination of dormancy-breaked seed was completely dependent on light. Shoot emergence ratio(%) was decreased with increase of planting depth ; for example, only 18% of rhizome segments planted in the depth of 4cm under soil surface emerged above soil surface. Flooding at earlier growth stage resulted in significant decrease in shoot emergence as well as in dry weight. The germinablity of rhizome was almost lost as a decreased in fresh weight reached to 50%. Usually, green kyllinga was sensitive to herbicides such as bentazone, bensulfuron and benfuresate etc. which were known to be effective in Cyperaceae weeds, indicating that green kyllinga can be used as a representative plant in the screening of herbicides for Cyperus weeds.

  • PDF

A Study on Durability Test of Cemented Soils (시멘트 혼합토의 내구성 평가법에 관한 연구)

  • Park, Sung-Sik;Hwang, Se-Hoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.11
    • /
    • pp.79-86
    • /
    • 2012
  • Cemented soils have been used for subbase or base materials of roads, backfill materials of retaining walls and cofferdam. Such cemented soils can be degraded due to repeated wetting and drying or various weathering actions. Unlike rocks, a standard method was not defined for evaluating the durability of cemented soils. In this study, a slaking durability test and an ultrasound cleaner were used for developing a new durability test method for cemented soils. For durability tests, cemented sands with different cement ratios (4, 6, 8, and 12%) with cylindrical specimens were prepared and then air cured or under-water cured for three days. Three-day-cured specimens were dried for one day and then submerged for one day before testing. The weight loss after the slake durability test or ultrasonic cleaner operation for 10 or 20 min was measured and used for assessing durability. When a cement ratio was 4%, the weight loss from ultrasonic cleaner test was 7-25% but that from slake durability test was as much as 30-60%. For specimens with cement ratio of more than 8%, the weight loss was less than 10% from both tests. A durability index increased with increasing a cement ratio. The durability index of under-water cured specimen was higher than that of air cured specimen. The ultrasonic cleaner test was found to be an effective tool for durability assessment of cemented sands rather than the slake durability test.

Evaluating the Influence of Post-Earthquake Rainfall on Landslide Susceptibility through Soil Physical Properties Changes (지진이후 강우의 산사태 발생 영향성 평가를 위한 토양물성값 변화 분석)

  • Junpyo Seo;Song Eu;KiHwan Lee;Giha Lee;Sewook Oh
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.270-283
    • /
    • 2024
  • Purpose: Considering the rising frequency of earthquakes in Korea, it is crucial to revise the rainfall thresholds for landslide triggering following earthquake events. This study was conducted to provide scientific justification and preliminary data for adjusting rainfall thresholds for landslide early warnings after earthquakes through soil physical experiments. Method: The study analyzed the change in soil shear strength by direct shear tests on disturbed and undisturbed samples collected from cut slopes. Also, The study analyzed the soil strength parameters of remolded soil samples subjected to drying and wetting conditions, focusing on the relationship between the degree of saturation after submergence and the strength parameters. Result: Compaction water content variation in direct shear tests showed that higher water content and saturation in disturbed samples led to a significant decrease in cohesion (over 50%) and a reduction in shear resistance angle (1~2°). Additionally, during the ring shear tests, the shear strength was observed to gradually decrease once water was supplied to the shear plane. The maximum shear strength decreased by approximately 65-75%, while the residual shear strength decreased by approximately 53-60%. Conclusion: Seismic activity amplifies landslide risk during subsequent rainfall, necessitating proactive mitigation strategies in earthquake-prone areas. This research is anticipated to provide scientific justification and preliminary data for reducing the rainfall threshold for landslide initiation in earthquake-susceptible regions.

A Study of Dispersion Characteristics of Sunsik Using Fluidized-Bed Granulator (유동층 과립기를 이용한 선식의 분산 특성)

  • Kim, Gorae;Hwang, Yunhee;Lee, Seokhoon
    • Food Engineering Progress
    • /
    • v.21 no.3
    • /
    • pp.267-272
    • /
    • 2017
  • To improve dispersibility of cereal powder without additives, granulation of cereal powder was conducted using fluidized-bed granulator. Operation condition was sample 300 g, internal temperature $40^{\circ}C$, ventilation speed $30-90m^3/h$, inlet temperature $90^{\circ}C$ and spray pressure 2.5 bar. The amount of distilled water (20-45%) as binder, granulation time (10-15 min) and drying time (3-10 min) were controlled. Mean diameter over volume (Brouckere mean, $D_{4,3}$) was increased from $123{\mu}m$ to $263{\mu}m$ and dispersibility was improved from 73% to 92.25% at experiment conditions. Wettability (wetting time) was drastically decreased from 5,000 second to 7 second. Granulation of cereal powder did not affect sinkability and mean diameter over volume as wet analysis was about the same between raw and granulated cereals. Such phenomenon means that granulation with only water as binder enables cereal powder to disperse in water or milk without rapid sedimentation.

Mobility of Nitrate and Phosphate through Small Lysimeter with Three Physico-chemically Different Soils (소형 라이시메터시험을 통한 토양특성에 따른 질산과 인산의 이동성 비교)

  • Han, Kyung-Hwa;Ro, Hee-Myong;Cho, Hyun-Jun;Kim, Lee-Yul;Hwang, Seon-Woong;Cho, Hee-Rae;Song, Kwan-Cheol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.4
    • /
    • pp.260-266
    • /
    • 2008
  • Small lysimeter experiment under rain shelter plastic film house was conducted to investigate the effect of soil characteristics on the leaching and soil solution concentration of nitrate and phosphate. Three soils were obtained from different agricultural sites of Korea: Soil A (mesic family of Typic Dystrudepts), Soil B (mixed, mesic family of Typic Udifluvents), and Soil C (artificially disturbed soils under greenhouse). Organic-C contents were in the order of Soil C ($32.4g\;kg^{-1}$) > Soil B ($15.0g\;kg^{-1}$) > Soil A ($8.1g\;kg^{-1}$). Inorganic-N concentration also differed significantly among soils, decreasing in the order of Soil B > Soil C > Soil A. Degree of P saturation (DPS) of Soil C was 178%, about three and fifteen times of Soil B (38%) and Soil A (6%). Prior to treatment, soils in lysimeters (dia. 300 mm, soil length 450 mm) were tabilized by repeated drying and wetting procedures for two weeks. After urea at $150kg\;N\;ha^{-1}$ and $KH_2PO_4$ at $100kg\;P_2O_5\;ha^{-1}$ were applied on the surface of each soil, total volume of irrigation was 213 mm at seven occasions for 65 days. At 13, 25, 35, 37, and 65 days after treatment, soil solution was sampled using rhizosampler at 10, 20, and 30 cm depth and leachate was sampled by free drain out of lysimeter. The volume of leachate was the highest in Soil C, and followed by the order of Soils A and B, whereas the amount of leached nitrate had a reverse trend, i.e. Soil B > Soil A > Soil C. Soil A and B had a significant increase of the nitrate concentration of soil solution at depth of 10 cm after urea-N treatment, but Soil C did not. High nitrate mobility of Soil B, compared to other soils, is presumably due to relatively high clay content, which could induce high extraction of nitrate of soil matrix by anion exclusion effect and slow rate of water flow. Contrary to Soil B, high organic matter content of Soil C could be responsible for its low mobility of nitrate, inducing preferential flow by water-repellency and rapid immobilization of nitrate by a microbial community. Leached phosphate was detected in Soil C only, and continuously increased with increasing amount of leachate. The phosphate concentration of soil solution in Soil B was much lower than in Soil C, and Soil A was below detection limit ($0.01mg\;L^{-1}$), overall similar to the order of degree of P saturation of soils. Phosphate mobility, therefore, could be largely influenced by degree of P saturation of soils but connect with apparent leaching loss only more than any threshold of P accumulation.